Methods for Improving Foot Displacement Measurements Calculated from Inertial Sensors

The use of inertial sensors to measure human movement has recently gained momentum with the advent of low cost micro-electro-mechanical systems (MEMS) technology. These sensors comprise accelerometer and gyroscopes which measure accelerations and angular velocities respectively. Secondary quantities such as displacement can be obtained by integration of these quantities, a method which presents challenging issues due to the problem of accumulative sensor errors. This chapter investigates the spectral evaluation of individual sensor errors and looks at the effectiveness of minimizing these errors using static digital filters. The primary focus is on the derivation of foot displacement data from inertial sensor measurements. The importance of foot, in particular toe displacement measurements is evident in the context of tripping and falling which are serious health concerns for the elderly. The Minimum Toe Clearance (MTC) as an important gait variable for falls-risk prediction and assessment, and therefore the measurement variable of interest. A brief sketch of the current devices employing accelerometers and gyroscopes is presented, highlighting the problems and difficulties reported in literature to achieve good precision. These have been mainly due to the presence of sensor errors and the error accumulative process employed in obtaining displacement measurements. The investigation first proceeds to identify the location of these sensor errors in the frequency domain using the Fast Fourier Transform (FFT) on raw inertial sensor data. The frequency content of velocity and displacement measurements obtained from integrating the inertial data using a well known strap-down method is then explored. These investigations revealed that large sensor errors occurred mainly in the low frequency spectrum while white noise exists in all frequency spectra. The efficacy of employing a band-pass filter to remove a large portion of these errors and their effect on the derived displacements is elaborated on. The cross-correlation of the FFT power spectra from a highly accurate optical measurement system and processed sensor data is used as a metric to evaluate the performance of the band-pass filter at several stages of the processing stage. The motivation is that a more fundamental method would require less computational demand and could lead to more efficient implementations in low-power and systems with limited resources, so that portable sensor based motion measurement system would provide a good degree of measurement accuracy.

[1]  Liu Ming,et al.  Identification of Individual Walking Patterns Using Gait Acceleration , 2007, 2007 1st International Conference on Bioinformatics and Biomedical Engineering.

[2]  Shirley Beul-Leusmann,et al.  E-Health, Assistive Technologies and Applications for Assisted Living: Challenges and Solutions , 2011 .

[3]  Hermanus J. Hermens,et al.  Inertial sensing in ambulatory back load estimation , 1996, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  John D. Ainsworth,et al.  The PsyGrid Experience: Using Web Services in the Study of Schizophrenia , 2007, Int. J. Heal. Inf. Syst. Informatics.

[5]  Angelo M. Sabatini,et al.  Assessment of walking features from foot inertial sensing , 2005, IEEE Transactions on Biomedical Engineering.

[6]  Baihua Li,et al.  Recognition of human periodic movements from unstructured information using a motion-based frequency domain approach , 2006, Image Vis. Comput..

[7]  Yinghua Yu,et al.  The Crossmodal between the Visual and Tactile for Motion Perception , 2013 .

[8]  M. Palaniswami,et al.  Frequency analysis of inertial sensor data for measuring toe clearance , 2008, 2008 International Conference on Intelligent Sensors, Sensor Networks and Information Processing.

[9]  Marimuthu Palaniswami,et al.  Support vector machines for automated gait classification , 2005, IEEE Transactions on Biomedical Engineering.

[10]  Chris T.M. Baten,et al.  Ambulatory Low Back Load Exposure Estimation , 2000 .

[11]  Joseph A. Paradiso,et al.  Shoe-integrated sensor system for wireless gait analysis and real-time feedback , 2002, Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology.

[12]  Liu Ming,et al.  A Wearable Acceleration Sensor System for Gait Recognition , 2007, 2007 2nd IEEE Conference on Industrial Electronics and Applications.

[13]  M.R. Popovic,et al.  A reliable gait phase detection system , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[14]  A. Hof,et al.  Assessment of spatio-temporal gait parameters from trunk accelerations during human walking. , 2003, Gait & posture.

[15]  Jinglong Wu Biomedical Engineering and Cognitive Neuroscience for Healthcare: Interdisciplinary Applications , 2012 .

[16]  Anupam Shukla,et al.  Intelligent Medical Technologies and Biomedical Engineering: Tools and Applications , 2010 .

[17]  S. Miyazaki,et al.  Long-term unrestrained measurement of stride length and walking velocity utilizing a piezoelectric gyroscope , 1997, IEEE Transactions on Biomedical Engineering.

[18]  S. Taylor,et al.  Fuzzy Logic-based Recognition of Gait Changes due to Trip-related Falls , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[19]  Kamiar Aminian,et al.  A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes , 2005, IEEE Transactions on Biomedical Engineering.

[20]  Koray S Erer,et al.  Adaptive usage of the Butterworth digital filter. , 2007, Journal of biomechanics.

[21]  Thierry Keller,et al.  Experimental Evaluation of the Gyroscope Sensor used in a New Gait Phase Detection System , 1999 .

[22]  Kirsi Helkala,et al.  Gait recognition using acceleration from MEMS , 2006, First International Conference on Availability, Reliability and Security (ARES'06).

[23]  J. R. Moorman,et al.  Heart Rate Characteristics Monitoring in the NICU: A New Tool for Clinical Care and Research , 2012 .

[24]  Thilo Pfau,et al.  A method for deriving displacement data during cyclical movement using an inertial sensor , 2005, Journal of Experimental Biology.

[25]  Hongyin Lau,et al.  The reliability of using accelerometer and gyroscope for gait event identification on persons with dropped foot. , 2008, Gait & posture.

[26]  Kamiar Aminian,et al.  Measurement of stand-sit and sit-stand transitions using a miniature gyroscope and its application in fall risk evaluation in the elderly , 2002, IEEE Transactions on Biomedical Engineering.

[27]  A. Bourke,et al.  The identification of vertical velocity profiles using an inertial sensor to investigate pre-impact detection of falls. , 2008, Medical Engineering and Physics.