Development of a novel intra-vaginal transducer with improved dynamic response

Limitations of standard clinical pressure transducers have hampered our ability to provide reliable measurements of intra-abdominal pressure (IAP) during physical activities. To overcome these limitations, a novel intravaginal transducer (IVT) capable of accurate, reliable, and continuous IAP measurements during normal activity was developed. The design was validated through comparison with standard clinical pressure transducers in both bench top and clinical tests. The IVT demonstrated an improved dynamic response when compared to a standard rectal balloon catheter. Additionally, the radially symmetric design allows for accurate measurement within non-fluid-filled tissue cavities and simple placement within the vaginal canal. This is an advantage over sensor-tipped transducers which are only reliable in fluid-filled compartments. The IVT design presented here is preliminary to a wireless version that will allow for IAP measurement during activities outside the clinic.

[1]  R. S. Anderson,et al.  Microtransducer urethral profile methodology: variations caused by transducer orientation. , 1983, The Journal of urology.

[2]  Morton B. Brown,et al.  A multicentered comparison of measurements obtained with microtip and external water pressure transducers , 2006, International Urogynecology Journal.

[3]  Manu L. N. G. Malbrain,et al.  Different techniques to measure intra-abdominal pressure (IAP): time for a critical re-appraisal , 2004, Intensive Care Medicine.

[4]  Peter K. Sand,et al.  Comparison of Microtransducer and Fiberoptic Catheters for Urodynamic Studies , 2001, Obstetrics and gynecology.

[5]  M. Cheatham,et al.  Intraabdominal pressure: a revised method for measurement. , 1998, Journal of the American College of Surgeons.

[6]  K. Wise,et al.  A wireless microsystem for the remote sensing of pressure, temperature, and relative humidity , 2005, Journal of Microelectromechanical Systems.

[7]  T. Kessler,et al.  Air charged and microtip catheters cannot be used interchangeably for urethral pressure measurement: a prospective, single-blind, randomized trial. , 2008, The Journal of urology.

[8]  C. Gibbs,et al.  Simultaneous urethral pressure profilometry using a microtip transducer catheter in the bitch: Effects of bitch position and transducer orientation , 1990 .

[9]  B. Guslits,et al.  Increases in intra-abdominal pressure affect pulmonary compliance. , 1995, Archives of surgery.

[10]  N. R. de Melo,et al.  Efficacy and safety of a contraceptive vaginal ring (NuvaRing) compared with a combined oral contraceptive: a 1-year randomized trial. , 2005, Contraception.

[11]  T. J. Iberti,et al.  A simple technique to accurately determine intra-abdominal pressure. , 1987, Critical care medicine.

[12]  Mark R Stoker,et al.  Principles of pressure transducers, resonance, damping and frequency response , 2004 .

[13]  T. A. Mccarthy,et al.  Validity of rectal pressure measurements as indication of intra-abdominal pressure changes during urodynamic evaluation. , 1982, Urology.

[14]  D. Pretorius,et al.  The vaginal pressure profile , 2005, Neurourology and urodynamics.

[15]  D. Griffiths,et al.  Standardisation of urethral pressure measurement: Report from the standardisation sub‐committee of the International Continence Society , 2002, Neurourology and urodynamics.

[16]  I. Kron,et al.  The Measurement of Intra‐abdominal Pressure as a Criterion for Abdominal Re‐exploration , 1984, Annals of surgery.

[17]  P. Hunziker Accuracy and dynamic response of disposable pressure transducertubing systems , 1987, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[18]  J. Wilken,et al.  Postoperative Activity Restrictions: Any Evidence? , 2006, Obstetrics and gynecology.

[19]  John C. Fang,et al.  Comparison of Air-Coupled Balloon Esophageal and Anorectal Manometry Catheters with Solid-State Esophageal Manometry and Water-Perfused Anorectal Manometry Catheters , 2004, Digestive Diseases and Sciences.

[20]  I. Nygaard,et al.  Vaginal pessaries for the management of stress and mixed urinary incontinence , 2004, International Urogynecology Journal.