Blending of brain-machine interface and vision-guided autonomous robotics improves neuroprosthetic arm performance during grasping

BackgroundRecent studies have shown that brain-machine interfaces (BMIs) offer great potential for restoring upper limb function. However, grasping objects is a complicated task and the signals extracted from the brain may not always be capable of driving these movements reliably. Vision-guided robotic assistance is one possible way to improve BMI performance. We describe a method of shared control where the user controls a prosthetic arm using a BMI and receives assistance with positioning the hand when it approaches an object.MethodsTwo human subjects with tetraplegia used a robotic arm to complete object transport tasks with and without shared control. The shared control system was designed to provide a balance between BMI-derived intention and computer assistance. An autonomous robotic grasping system identified and tracked objects and defined stable grasp positions for these objects. The system identified when the user intended to interact with an object based on the BMI-controlled movements of the robotic arm. Using shared control, BMI controlled movements and autonomous grasping commands were blended to ensure secure grasps.ResultsBoth subjects were more successful on object transfer tasks when using shared control compared to BMI control alone. Movements made using shared control were more accurate, more efficient, and less difficult. One participant attempted a task with multiple objects and successfully lifted one of two closely spaced objects in 92 % of trials, demonstrating the potential for users to accurately execute their intention while using shared control.ConclusionsIntegration of BMI control with vision-guided robotic assistance led to improved performance on object transfer tasks. Providing assistance while maintaining generalizability will make BMI systems more attractive to potential users.Trial registrationNCT01364480 and NCT01894802.

[1]  Andrew B Schwartz,et al.  Neuroprosthetic control and tetraplegia – Authors'reply , 2013, The Lancet.

[2]  Andrew S. Whitford,et al.  Cortical control of a prosthetic arm for self-feeding , 2008, Nature.

[3]  Vikash Gilja,et al.  Long-term Stability of Neural Prosthetic Control Signals from Silicon Cortical Arrays in Rhesus Macaque Motor Cortex , 2010 .

[4]  John D. Simeral,et al.  An assistive decision-and-control architecture for force-sensitive hand–arm systems driven by human–machine interfaces , 2015, Int. J. Robotics Res..

[5]  R. Lyle A performance test for assessment of upper limb function in physical rehabilitation treatment and research , 1981, International journal of rehabilitation research. Internationale Zeitschrift fur Rehabilitationsforschung. Revue internationale de recherches de readaptation.

[6]  Nitish V. Thakor,et al.  Demonstration of a Semi-Autonomous Hybrid Brain–Machine Interface Using Human Intracranial EEG, Eye Tracking, and Computer Vision to Control a Robotic Upper Limb Prosthetic , 2014, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[7]  L. Wheaton,et al.  Motor performance benefits of matched limb imitation in prosthesis users , 2014, Experimental Brain Research.

[8]  Rajesh P. N. Rao,et al.  Control of a humanoid robot by a noninvasive brain–computer interface in humans , 2008, Journal of neural engineering.

[9]  Richard A. Andersen,et al.  A collaborative BCI approach to autonomous control of a prosthetic limb system , 2014, 2014 IEEE International Conference on Systems, Man, and Cybernetics (SMC).

[10]  Reinhard Koch,et al.  Nonlinear Body Pose Estimation from Depth Images , 2005, DAGM-Symposium.

[11]  A. Schwartz,et al.  High-performance neuroprosthetic control by an individual with tetraplegia , 2013, The Lancet.

[12]  Martial Hebert,et al.  Autonomy infused teleoperation with application to brain computer interface controlled manipulation , 2017, Autonomous Robots.

[13]  M L Boninger,et al.  Ten-dimensional anthropomorphic arm control in a human brain−machine interface: difficulties, solutions, and limitations , 2015, Journal of neural engineering.

[14]  Martial Hebert,et al.  Autonomy Infused Teleoperation with Application to BCI Manipulation , 2015, Robotics: Science and Systems.

[15]  J. Randall Flanagan,et al.  Coding and use of tactile signals from the fingertips in object manipulation tasks , 2009, Nature Reviews Neuroscience.

[16]  M. Srinivasan,et al.  Developments in brain-machine interfaces from the perspective of robotics. , 2009, Human movement science.

[17]  Gerhard Friehs,et al.  Intra-day signal instabilities affect decoding performance in an intracortical neural interface system , 2013, Journal of neural engineering.

[18]  L. Miller,et al.  Restoring sensorimotor function through intracortical interfaces: progress and looming challenges , 2014, Nature Reviews Neuroscience.

[19]  Martial Hebert,et al.  An integrated system for autonomous robotics manipulation , 2012, 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[20]  Wolfram Burgard,et al.  Robotics: Science and Systems XV , 2010 .

[21]  Jeffrey C. Trinkle,et al.  Robotics: Science and Systems , 2010, AI Mag..

[22]  Alexander Toshev,et al.  Shape-based object recognition in videos using 3D synthetic object models , 2009, 2009 IEEE Conference on Computer Vision and Pattern Recognition.

[23]  Michael L Boninger,et al.  Functional priorities, assistive technology, and brain-computer interfaces after spinal cord injury. , 2013, Journal of rehabilitation research and development.

[24]  Nicolas Y. Masse,et al.  Reach and grasp by people with tetraplegia using a neurally controlled robotic arm , 2012, Nature.

[25]  Zhao Wang,et al.  How Autonomy Impacts Performance and Satisfaction: Results From a Study With Spinal Cord Injured Subjects Using an Assistive Robot , 2012, IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans.

[26]  J. Huggins,et al.  What would brain-computer interface users want: opinions and priorities of potential users with spinal cord injury. , 2015, Archives of physical medicine and rehabilitation.