Stiffness analysis of glued connection of the timber-concrete structure

Abstract This paper presents results of experimental and mathematical analysis of stiffness characteristics of a composite timber-concrete structure. The composite timberconcrete structure presented herein is non-typical compared to similar types of building structures. The interaction between the timber and concrete part of the composite cross-section is not based on metal connecting elements, but it is ensured by a glued-in perforated mesh made of plywood. The paper presents results of experimental and mathematical analysis for material alternatives of the solution of the glued joint. The slip modulus values were determined experimentally. Data obtained from the experiment evaluated by means of regression analysis. Test results were also used as input data for the compilation of a 3D model of a composite structure by means of the 3D finite element model. On the basis of result evaluation, it can be stated that the stress-deformation behaviour at shear loading of this specific timber-concrete composite structure can be affected by the type of glue used. Parameters of the 3D model of both alternative of the structure represent well the behaviour of the composite structure and the model can be used for predicting design parameters of a building structure.

[1]  Roberto Capozucca Bond stress system of composite concrete—timber beams , 1998 .

[2]  Ario Ceccotti,et al.  Composite concrete‐timber structures , 2002 .

[3]  Massimo Fragiacomo,et al.  Connections for composite concrete slab and LVL flooring systems , 2008 .

[4]  C. Borsellino,et al.  Mechanical characterization of adhesive joints with dissimilar substrates for marine applications , 2013 .

[5]  Michael Kaliske,et al.  Three-dimensional numerical analyses of load-bearing behavior and failure of multiple double-shear dowel-type connections in timber engineering , 2010 .

[6]  Josef Machacek,et al.  Perforated shear connectors , 2002 .

[7]  Massimo Fragiacomo,et al.  Long-term and collapse tests on a timber-concrete composite beam with glued-in connection , 2007 .

[8]  Elzbieta Lukaszewska,et al.  Development of prefabricated timber-concrete composite floors , 2009 .

[9]  James William O'Neill The Fire Performance of Timber-Concrete Composite Floors , 2009 .

[10]  Jana Daňková Timber - Concrete Structural Element with Glued Steel Mesh , 2014 .

[11]  Alfredo M. P. G. Dias,et al.  Mechanical behaviour of timber-concrete joints , 2005 .

[12]  Robert Ian Mackie,et al.  Two-dimensional creep analysis of structural adhesive joints , 1993 .

[13]  Tomasz Sadowski,et al.  Experimental and numerical investigation of plywood progressive failure in CT tests , 2008 .

[14]  Massimo Fragiacomo,et al.  Performance of connections for prefabricated timber–concrete composite floors , 2008 .

[15]  David Yeoh,et al.  State of the Art on Timber-Concrete Composite Structures: Literature Review , 2011 .