Particle selection for laser-accelerated proton therapy feasibility study.

In this paper we present calculations for the design of a particle selection system for laser-accelerated proton therapy. Laser-accelerated protons coming from a thin high-density foil have broad energy and angular spectra leading to dose distributions that cannot be directly used for therapeutic applications. Our solution to this problem is a compact particle selection and collimation device that delivers small pencil beams of protons with desired energy spectra. We propose a spectrometer-like particle selection and beam modulation system in which the magnetic field will be used to spread the protons spatially according to their energies and emitting angles. Subsequently, an aperture will be used to select the protons within a therapeutic window of energy (energy modulation). It will be shown that for the effective proton spatial differentiation, the primary collimation device should be used, which will collimate protons to the desired angular distribution and limit the spatial mixing of different energy protons once they have traveled through the magnetic system. Due to the angular proton distribution, the spatial mixing of protons of different energies will always be present and it will result in a proton energy spread with the width depending on the energy. For 250 MeV protons, the width (from the maximum to the minimum energy) is found to be 50 MeV for the magnetic field configuration used in our calculations. As the proton energy decreases, its energy width decreases as well, and for 80 MeV protons it equals 9 MeV. The presence of the energy width in the proton energy distribution will modify the depth dose curves needed for the energy modulation calculation. The matching magnetic field setup will ensure the refocusing of the selected protons and the final beam will be collimated by the secondary collimator. The calculations presented in this article show that the dose rate that the selection system can yield is on the order of D=260 Gy/min for a field size of 1 x 1 cm2.

[1]  R. Kristal,et al.  Fast ions and hot electrons in the laser–plasma interaction , 1986 .

[2]  Gu,et al.  Forward ion acceleration in thin films driven by a high-intensity laser , 2000, Physical review letters.

[3]  Wojciech Rozmus,et al.  A symplectic integration algorithm for separable Hamiltonian functions , 1990 .

[4]  Gerard Mourou,et al.  Compression of amplified chirped optical pulses , 1985 .

[5]  W. Kruer,et al.  J×B heating by very intense laser light , 1985 .

[6]  W. Beeckman,et al.  The proton therapy system for MGH's NPTC: equipment description and progress report , 1996 .

[7]  B Shahine,et al.  Particle in cell simulation of laser-accelerated proton beams for radiation therapy. , 2002, Medical physics.

[8]  Gert Moliere,et al.  Theorie der Streuung schneller geladener Teilchen II Mehrfach-und Vielfachstreuung , 1948 .

[9]  Daniel W. Miller,et al.  Proton radiation therapy (PRT) for pediatric optic pathway gliomas: comparison with 3D planned conventional photons and a standard photon technique. , 1999, International journal of radiation oncology, biology, physics.

[10]  Edward B. Clark,et al.  Energetic heavy-Ion and proton generation from ultraintense laser-plasma interactions with solids , 2000, Physical review letters.

[11]  A. Brahme,et al.  A generalized pencil beam algorithm for optimization of radiation therapy. , 1994, Medical physics.

[12]  G. Sandison,et al.  Intensity and energy modulated radiotherapy with proton beams: variables affecting optimal prostate plan. , 2002, Medical physics.

[13]  T Bortfeld,et al.  An analytical approximation of the Bragg curve for therapeutic proton beams. , 1997, Medical physics.

[14]  T. C. Sangster,et al.  Intense high-energy proton beams from Petawatt-laser irradiation of solids. , 2000, Physical review letters.

[15]  S M Seltzer,et al.  AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology. , 2001, Medical physics.

[16]  P. V. Vavilov IONIZATION LOSSES OF HIGH-ENERGY HEAVY PARTICLES , 1957 .

[17]  K. Nishihara,et al.  Generation of collimated beams of relativistic ions in laser-plasma interactions , 2000 .

[18]  C. Birdsall,et al.  Plasma Physics via Computer Simulation , 2018 .

[19]  R J Schulz,et al.  On the role of intensity-modulated radiation therapy in radiation oncology. , 2002, Medical physics.

[20]  Michael D. Perry,et al.  Ultrahigh‐Intensity Lasers: Physics of the Extreme on a Tabletop , 1998 .

[21]  K. Mima,et al.  High-energy ion generation in interaction. of short laser pulse with high-density plasma , 2002 .

[22]  G. Moliere,et al.  Theory of the scattering of fast charged particles. 2. Repeated and multiple scattering , 1948 .

[23]  Z. Sheng,et al.  Electron acceleration by a short relativistic laser pulse at the front of solid targets. , 2000, Physical review letters.

[24]  L. Verhey,et al.  Advanced prostate cancer: the results of a randomized comparative trial of high dose irradiation boosting with conformal protons compared with conventional dose irradiation using photons alone. , 1995, International journal of radiation oncology, biology, physics.

[25]  S. Wilks,et al.  Absorption of ultrashort, ultra-intense laser light by solids and overdense plasmas , 1997 .

[26]  K. Nishihara,et al.  Bursts of Superreflected Laser Light from Inhomogeneous Plasmas due to the Generation of Relativistic Solitary Waves , 1999 .

[27]  Lev Davidovich Landau,et al.  On the energy loss of fast particles by ionization , 1944 .

[28]  A. Lomax,et al.  Intensity modulation methods for proton radiotherapy. , 1999, Physics in medicine and biology.

[29]  E. Pedroni Therapy planning system for the SIN-pion therapy facility. , 1981, Strahlentherapie. Sonderbande.

[30]  Gert Moliere,et al.  Theorie der Streuung schneller geladener Teilchen I. Einzelstreuung am abgeschirmten Coulomb-Feld , 1947 .

[31]  E. Keil,et al.  Zur Einfach- und Mehrfachstreuung geladener Teilchen , 1960 .

[32]  T. Tajima,et al.  Laser Electron Accelerator , 1979 .

[33]  T. Bortfeld,et al.  Methods of image reconstruction from projections applied to conformation radiotherapy. , 1990, Physics in medicine and biology.

[34]  Kjellberg Rn Stereotactic Bragg peak proton beam radiosurgery for cerebral arteriovenous malformations. , 1986 .

[35]  Reinhard W. Schulte,et al.  Conformal proton therapy for prostate carcinoma. , 1998, International journal of radiation oncology, biology, physics.