A new digital ground-fault protection system for generator-transformer unit

Ground faults are one of most often reasons of damages in stator windings of large generators. Under certain conditions, as a result of ground-fault protection systems maloperation, ground faults convert into high-current faults, causing severe failures in power system. Numerous publications in renowned journals and magazines testify about ground-fault matter importance and problems reported by exploitators confirm opinions, that some issues concerning ground-fault protection of large generators have not been solved yet or have been solved insufficiently. In this paper a new conception of a digital ground-fault protection system for stator winding of large generator was proposed. The process of intermittent arc ground fault in stator winding has been briefly discussed and actual ground-fault voltage waveforms were presented. A new relaying algorithm, based on third harmonic voltage measurement was also drawn and the methods of its implementation and testing were described.

[1]  J. Pope,et al.  A Comparison of 100% Stator Ground Fault Protection Schemes for Generator Stator Windings , 1984, IEEE Transactions on Power Apparatus and Systems.

[2]  G. Goertzel An Algorithm for the Evaluation of Finite Trigonometric Series , 1958 .

[3]  M. Zielichowski,et al.  Influence of difference system parameters on operating conditions of third harmonic ground-fault protection system of unit-connected generator , 2004, IEEE Transactions on Power Delivery.

[4]  Helmut Ungrad,et al.  Protection Techniques in Electrical Energy Systems , 1995 .

[5]  O. P. Malik,et al.  Adaptive ground fault protection schemes for turbogenerator based on third harmonic voltages , 1990 .

[6]  Yin Xianggen,et al.  Improvement of subharmonic injection schemes for huge hydro-generator stator ground fault protection , 2002, Proceedings. International Conference on Power System Technology.

[7]  Tai Nengling,et al.  Wavelet-based ground fault protection scheme for generator stator winding , 2002 .

[8]  L. Pazmandi Stator earth-leakage protection for large generators , 1975, IEEE Transactions on Power Apparatus and Systems.

[9]  Om P. Malik,et al.  Generator stator winding protection with 100% enhanced sensitivity , 2002 .

[10]  M. Zielichowski,et al.  Optimization of operating conditions of third harmonic ground-fault protection system of generator-transformer unit with two-states transverse parameters , 2004, IEEE Transactions on Power Delivery.

[11]  Tai Nengling,et al.  Stator ground fault protection based on phase angle differential of delta third harmonic voltages , 2005 .