Concurrent Repair of Inguinal Hernias with Mesh Application During Transperitoneal Robotic-assisted Radical Prostatectomy: Is it Safe.

PURPOSE To assessment the safety of concurrent repair of inguinal hernia (IH) with mesh application during transperitoneal robotic-assisted radical prostatectomy(RARP). MATERIALS AND METHODS Data of 20 patients (totally 25 procedures) who performed concurrent IH repair with mesh application during RARP were retrospectively enrolled in this study. Preoperative patient characteristics, intra and postoperative parameters (pathological Gleason grade, prostate volume at surgical specimen, operative time, herniorrhaphy time, estimated blood loss, complications, time of hospitalization, catheterization, and drainage) were evaluated. Standard PSA control and postoperative complications of mesh application such as herniarecurrence, mesh infection, seroma formation and groin pain were evaluated at every follow-up visits (every three in the first year, then every 6 months in years 2 to 5 and annually thereafter. RESULT The mean age was 66 ± 8 years in our population. Fifteen (60 %) patients had a unilateral hernia and 5 (40%) patients had bilateral hernias. The mean operative time was 139 ± 21minutes and estimated mean blood loss was 108 ± 76 mL. The mean duration of IH repair in patients which was 27 ± 5 (range: 17- 40) minutes. The mean time of drainage, hospitalization, and catheterization were 2.5 ± 0.8 days (range: 2-6), 4 ± 0.9 days (range: 2-7) and 8.2 ± 1.9 days (range: 7-14), respectively. We did not observe any intra-operative complication due to RARP orIH repair. Wound evisceration at camera port site developed in only a patient on postoperative day 20. Our median follow-up time was 13 months and we did not observe mesh infection or hernia recurrence during follow-up. CONCLUSION Concurrent IH repair with RARP procedure seem to be easy to perform, effective and safe procedure.

[1]  Stuart Walker Repair , 2018, Design Realities.

[2]  John W. Davis,et al.  Robotic or Open Radical Prostatectomy in Men with Previous Transurethral Resection of Prostate. , 2017, Urologia Journal.

[3]  K. Kaler,et al.  Minimally Invasive Hernia Repair in Robot-Assisted Radical Prostatectomy. , 2016, Journal of endourology.

[4]  W. Ludwig,et al.  Inguinal Hernia Repair During Extraperitoneal Robot-Assisted Laparoscopic Radical Prostatectomy. , 2016, Journal of endourology.

[5]  A. Kural,et al.  Nonprosthetic Direct Inguinal Hernia Repair During Robotic Radical Prostatectomy. , 2016, Journal of endourology.

[6]  J. Stolzenburg,et al.  Robot-assisted laparoscopic total extraperitoneal hernia repair during prostatectomy: technique and initial experience , 2015, Central European journal of urology.

[7]  E. Utiyama,et al.  A retrospective review and observations over a 16-year clinical experience on the surgical treatment of chronic mesh infection. What about replacing a synthetic mesh on the infected surgical field? , 2015, Hernia.

[8]  P. Stattin,et al.  Incidence of Groin Hernia Repair After Radical Prostatectomy: A Population-Based Nationwide Study , 2014, Annals of surgery.

[9]  M. Misra,et al.  A prospective, randomized comparison of long-term outcomes: chronic groin pain and quality of life following totally extraperitoneal (TEP) and transabdominal preperitoneal (TAPP) laparoscopic inguinal hernia repair , 2013, Surgical Endoscopy.

[10]  S. Morales-Conde A new classification for seroma after laparoscopic ventral hernia repair , 2012, Hernia.

[11]  Z. Akbulut,et al.  Results of robotic radical prostatectomy in the hands of surgeons without previous laparoscopic radical prostatectomy experience , 2011, Turkish Journal of Medical Sciences.

[12]  J. Stolzenburg,et al.  Hernia repair during endoscopic extraperitoneal radical prostatectomy: outcome after 93 cases. , 2011, Journal of endourology.

[13]  G. Goldberg,et al.  Concurrent robotic trans‐abdominal pre‐peritoneal (TAP) herniorrhaphy during robotic‐assisted radical prostatectomy , 2010, The international journal of medical robotics + computer assisted surgery : MRCAS.

[14]  R. McLeod,et al.  Meta‐analysis of randomized controlled trials comparing open and laparoscopic ventral and incisional hernia repair with mesh , 2009, The British journal of surgery.

[15]  P. O’Dwyer,et al.  Traditional Preperitoneal Approach to Inguinal Hernias , 1994, Seminars in laparoscopic surgery.

[16]  T. Ahlering,et al.  Transperitoneal robotic-assisted laparoscopic radical prostatectomy and inguinal herniorrhaphy , 2008, Journal of robotic surgery.

[17]  T. Tsukamoto,et al.  Preoperative computed tomography finding predicts for postoperative inguinal hernia: new perspective for radical prostatectomy-related inguinal hernia. , 2006, Urology.

[18]  M. Comert,et al.  Fade or fate. Seroma in laparoscopic inguinal hernia repair. , 2006, Surgical endoscopy.

[19]  P. Walsh,et al.  Systematic detection and repair of subclinical inguinal hernias at radical retropubic prostatectomy. , 2005, Urology.

[20]  R. Rabenalt,et al.  Hernia repair during endoscopic (laparoscopic) radical prostatectomy. , 2003, Journal of laparoendoscopic & advanced surgical techniques. Part A.

[21]  H. Lau,et al.  Seroma following endoscopic extraperitoneal inguinal hernioplasty , 2003, Surgical Endoscopy And Other Interventional Techniques.

[22]  S. W. Dejter,et al.  Incidence of inguinal hernias following radical retropubic prostatectomy. , 1996, Urology.

[23]  C. Huggins,et al.  Simultaneous prostatectomy and inguinal herniorrhaphy. , 1949, Surgery, gynecology & obstetrics.