Blind deconvolution of 3D data in wide field fluorescence microscopy

In this paper we propose a blind deconvolution algorithm for wide field fluorescence microscopy. The 3D PSF is modeled after a parametrized pupil function. The PSF parameters are estimated jointly with the object in a maximum a posteriori framework. We illustrate the performances of our algorithm on experimental data and show significant resolution improvement notably along the depth. Quantitative measurements on images of calibration beads demonstrate the benefits of blind deconvolution both in terms of contrast and resolution compared to non-blind deconvolution using a theoretical PSF.

[1]  M. Gustafsson,et al.  Phase‐retrieved pupil functions in wide‐field fluorescence microscopy , 2004, Journal of microscopy.

[2]  L. Rudin,et al.  Nonlinear total variation based noise removal algorithms , 1992 .

[3]  Arie Feuer,et al.  Blind Image Deconvolution Using Machine Learning for Three-Dimensional Microscopy , 2010, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[4]  Michael Unser,et al.  A Fast Thresholded Landweber Algorithm for Wavelet-Regularized Multidimensional Deconvolution , 2008, IEEE Transactions on Image Processing.

[5]  J. Conan,et al.  MISTRAL: a myopic edge-preserving image restoration method, with application to astronomical adaptive-optics-corrected long-exposure images. , 2004, Journal of the Optical Society of America. A, Optics, image science, and vision.

[6]  A. Nehorai,et al.  Deconvolution methods for 3-D fluorescence microscopy images , 2006, IEEE Signal Processing Magazine.

[7]  Ferréol Soulez,et al.  Fast model of space-variant blurring and its application to deconvolution in astronomy , 2011, 2011 18th IEEE International Conference on Image Processing.

[8]  J. Conchello,et al.  Parametric blind deconvolution: a robust method for the simultaneous estimation of image and blur. , 1999, Journal of the Optical Society of America. A, Optics, image science, and vision.

[9]  Daniel Sage,et al.  Comparison of Deconvolution Software in 3D Microscopy: A User Point of View—Part 1 , 2010 .

[10]  J. Sibarita Deconvolution microscopy. , 2005, Advances in biochemical engineering/biotechnology.

[11]  Franck Marchis,et al.  AIDA: an adaptive image deconvolution algorithm with application to multi-frame and three-dimensional data. , 2007, Journal of the Optical Society of America. A, Optics, image science, and vision.

[12]  J. Besag On the Statistical Analysis of Dirty Pictures , 1986 .

[13]  Jean-Baptiste Sibarita,et al.  Ultra-fast 4D microscopy and high throughput distributed deconvolution , 2002, Proceedings IEEE International Symposium on Biomedical Imaging.

[14]  P. Stokseth Properties of a Defocused Optical System , 1969 .

[15]  Eric Thiebaut,et al.  Optimization issues in blind deconvolution algorithms , 2002, SPIE Astronomical Telescopes + Instrumentation.