The accuracy of bony resection from patient-specific guides during total knee arthroplasty

PurposeIn patient-specifically instrumented (PSI) total knee arthroplasty, the correlation between the pre-operative surgical plan, accuracy of the cutting block, and intra-operative resection size is unclear. The aim of this study was to evaluate the ability to accurately execute the PSI surgical plan and to add to the merging information with respect to this technology with the hypothesis that the PSI blocks would demonstrate good accuracy with regard to the bony thickness of the resections.MethodsOne hundred and thirty TKAs using PSI (MRI/long-leg radiographs) were retrospectively analysed. All surgeries were conducted via similar surgical approach and technique, with resection performed after guide placement and alignment assessment. The bony cut thicknesses of the medial (MTP) and lateral tibial plateau (LTP), distal medial (DM), distal lateral (DL), posterior medial (PM) and posterior lateral (PL) femur were measured with a vernier calliper. The measured resection thickness was subtracted from the planned resection. Errors were defined as ≤1.5 mm (acceptable), 1.5–2.5 mm (borderline), and >2.5 mm (outliers).ResultsOverall, 81 (62.3 %) of the knees were free of outliers. The distal femur cut had the highest proportion of acceptable cut error with 209 of 260 total cuts acceptable (80.4 %). The tibial cuts had the lowest proportion of “acceptable” cuts (68.9 %). Tibial cuts had more outliers (33 of 260 cuts, 12.7 %) than the femur (39 of 520 cuts, 7.5 %) (p = 0.01). Pre-operative varus (n = 97) and valgus (n = 33) deformities demonstrated 7.7 % (45/482) and 13.6 % (27/198) of cuts which were outliers, respectively (p = 0.01).ConclusionPSI showed only fair to moderate accuracy with 62.3 % of the knees presenting no outliers. The tibia cutting guide was less accurate than the femur. Specific attention is needed when cutting the tibia and in correction of valgus deformity. Moreover, intra-operative verifying measurements can provide feedback to the accuracy of the surgical plan.Level of evidenceIV, case series with no comparison group.

[1]  Hiromasa Miura,et al.  Anatomical analysis of the femoral condyle in normal and osteoarthritic knees , 2004, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[2]  Andrea Ferretti,et al.  Evaluation of the accuracy of a patient-specific instrumentation by navigation , 2013, Knee Surgery, Sports Traumatology, Arthroscopy.

[3]  Graeme West,et al.  Operative efficiency and accuracy of patient‐specific cutting guides in total knee replacement , 2015, ANZ journal of surgery.

[4]  Johan Bellemans,et al.  Patient-specific instruments: industry’s innovation with a surgeon’s interest , 2013, Knee Surgery, Sports Traumatology, Arthroscopy.

[5]  A. Pillai,et al.  Assessing the Accuracy of Bone Resection by Cutting Blocks in Patient-Specific Total Knee Replacements , 2012, ISRN orthopedics.

[6]  William R Walsh,et al.  The accuracy of bone resections made during computer navigated total knee replacement. Do we resect what the computer plans we resect? , 2008, The Knee.

[7]  C. Pornrattanamaneewong,et al.  A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. , 2013, The bone & joint journal.

[8]  Denis Nam,et al.  Systematic Review of Patient-specific Instrumentation in Total Knee Arthroplasty: New but Not Improved , 2015, Clinical orthopaedics and related research.

[9]  Claudio Belvedere,et al.  Intra- and post-operative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement , 2014, Knee Surgery, Sports Traumatology, Arthroscopy.

[10]  J. Seon,et al.  Assessing the accuracy of patient-specific guides for total knee arthroplasty , 2016, Knee Surgery, Sports Traumatology, Arthroscopy.

[11]  N. Helmy,et al.  Accuracy of Patient Specific Cutting Blocks in Total Knee Arthroplasty , 2014, BioMed research international.

[12]  Sébastien Lustig,et al.  Unsatisfactory accuracy as determined by computer navigation of VISIONAIRE patient-specific instrumentation for total knee arthroplasty. , 2013, The Journal of arthroplasty.

[13]  David A. Parker,et al.  Patient-specific instrumentation for total knee arthroplasty does not match the pre-operative plan as assessed by intra-operative computer-assisted navigation , 2014, Knee Surgery, Sports Traumatology, Arthroscopy.

[14]  R. Barrack,et al.  Patient specific cutting blocks are currently of no proven value. , 2012, The Journal of bone and joint surgery. British volume.

[15]  Andrew A. Amis,et al.  The effect of overstuffing the patellofemoral joint on the extensor retinaculum of the knee , 2009, Knee Surgery, Sports Traumatology, Arthroscopy.

[16]  John J Callaghan,et al.  Reliability of templating with patient-specific instrumentation in total knee arthroplasty. , 2013, The journal of knee surgery.

[17]  Johan Bellemans,et al.  Patient-specific Guides Do Not Improve Accuracy in Total Knee Arthroplasty: A Prospective Randomized Controlled Trial , 2013, Clinical orthopaedics and related research.

[18]  H. Lee,et al.  Morphometric Study of the Pedicles of Thoracic and Lumbar Vertebrae in Koreans , 1994, Spine.

[19]  W. Bruce,et al.  Custom-fit total knee arthroplasty: our initial experience in 32 knees. , 2012, The Journal of arthroplasty.

[20]  S. Hofmann,et al.  Patient-specific total knee arthroplasty: the importance of planning by the surgeon , 2013, Knee Surgery, Sports Traumatology, Arthroscopy.

[21]  Robert L. Barrack,et al.  Are Patient-specific Cutting Blocks Cost-effective for Total Knee Arthroplasty? , 2012, Clinical orthopaedics and related research.

[22]  I. Harris,et al.  A multi-planar CT-based comparative analysis of patient-specific cutting guides with conventional instrumentation in total knee arthroplasty. , 2014, The Journal of arthroplasty.