Enhanced quantitative phase imaging in self-interference digital holographic microscopy using an electrically focus tunable lens.

Self-interference digital holographic microscopy (DHM) has been found particular suitable for simplified quantitative phase imaging of living cells. However, a main drawback of the self-interference DHM principle are scattering patterns that are induced by the coherent nature of the laser light which affect the resolution for detection of optical path length changes. We present a simple and efficient technique for the reduction of coherent disturbances in quantitative phase images. Therefore, amplitude and phase of the sample illumination are modulated by an electrically focus tunable lens. The proposed method is in particular convenient with the self-interference DHM concept. Results from the characterization of the method show that a reduction of coherence induced disturbances up to 70 percent can be achieved. Finally, the performance for enhanced quantitative imaging of living cells is demonstrated.

[1]  Gabriel Popescu,et al.  Fourier phase microscopy with white light. , 2013, Biomedical optics express.

[2]  Patrik Langehanenberg,et al.  Integral refractive index determination of living suspension cells by multifocus digital holographic phase contrast microscopy. , 2007, Journal of biomedical optics.

[3]  P Marquet,et al.  Exploring neural cell dynamics with digital holographic microscopy. , 2013, Annual review of biomedical engineering.

[4]  John A Rogers,et al.  Diffraction phase microscopy: monitoring nanoscale dynamics in materials science [invited]. , 2014, Applied optics.

[5]  Patrik Langehanenberg,et al.  Application of 3D tracking, LED illumination and multi-wavelength techniques for quantitative cell analysis in digital holographic microscopy , 2009, BiOS.

[6]  Pietro Ferraro,et al.  Dynamic DIC by digital holography microscopy for enhancing phase-contrast visualization , 2011, Biomedical optics express.

[7]  Anne E Carpenter,et al.  CellProfiler: image analysis software for identifying and quantifying cell phenotypes , 2006, Genome Biology.

[8]  P. Marquet,et al.  Marker-free phase nanoscopy , 2013, Nature Photonics.

[9]  Steffi Ketelhut,et al.  Quantitative Stain-Free and Continuous Multimodal Monitoring of Wound Healing In Vitro with Digital Holographic Microscopy , 2014, PloS one.

[10]  O. Haeberlé,et al.  High-resolution three-dimensional tomographic diffractive microscopy of transparent inorganic and biological samples. , 2009, Optics letters.

[11]  Patrik Langehanenberg,et al.  Characterisation of light emitting diodes (LEDs) for application in digital holographic microscopy for inspection of micro and nanostructured surfaces , 2008 .

[12]  Gert von Bally,et al.  Optimization of spatial phase shifting in endoscopic electronic speckle pattern interferometry , 2003 .

[13]  Wolfgang Osten,et al.  Quantitative phase imaging using a deep UV LED source. , 2014, Optics letters.

[14]  Xin Kang,et al.  An effective method for reducing speckle noise in digital holography , 2008 .

[15]  E. Cuche,et al.  Simultaneous amplitude-contrast and quantitative phase-contrast microscopy by numerical reconstruction of Fresnel off-axis holograms. , 1999, Applied optics.

[16]  Björn Kemper,et al.  Simplified approach for quantitative digital holographic phase contrast imaging of living cells. , 2011, Journal of biomedical optics.

[17]  B. Wattellier,et al.  Quadriwave lateral shearing interferometry for quantitative phase microscopy of living cells. , 2009, Optics express.

[18]  Lu Rong,et al.  Speckle noise reduction in digital holography by use of multiple polarization holograms , 2010 .

[19]  Wonshik Choi,et al.  Full-field and single-shot quantitative phase microscopy using dynamic speckle illumination. , 2011, Optics letters.

[20]  F. Dubois,et al.  Improved three-dimensional imaging with a digital holography microscope with a source of partial spatial coherence. , 1999, Applied optics.

[21]  B. Kemper,et al.  Digital holographic microscopy for live cell applications and technical inspection. , 2008, Applied optics.

[22]  B. Wattellier,et al.  Enhanced 3D spatial resolution in quantitative phase microscopy using spatially incoherent illumination. , 2014, Optics express.

[23]  N. Shaked,et al.  Compact and portable low-coherence interferometer with off-axis geometry for quantitative phase microscopy and nanoscopy. , 2013, Optics express.

[24]  Christian Depeursinge,et al.  Noninvasive characterization of the fission yeast cell cycle by monitoring dry mass with digital holographic microscopy. , 2009, Journal of biomedical optics.

[25]  R. Barer Interference Microscopy and Mass Determination , 1952, Nature.

[26]  O. Haeberlé,et al.  Tomographic diffractive microscopy and multiview profilometry with flexible aberration correction. , 2014, Applied optics.

[27]  J. Rogers,et al.  Spatial light interference microscopy (SLIM) , 2010, IEEE Photonic Society 24th Annual Meeting.

[28]  Huafeng Ding,et al.  Instantaneous Spatial Light Interference Microscopy. , 2010, Optics express.

[29]  Patrik Langehanenberg,et al.  Reduction of parasitic interferences in digital holographic microscopy by numerically decreased coherence length , 2012 .

[30]  Daniel Carl,et al.  Investigation of living pancreas tumor cells by digital holographic microscopy. , 2006, Journal of biomedical optics.

[31]  Daniel Carl,et al.  Parameter-optimized digital holographic microscope for high-resolution living-cell analysis. , 2004, Applied optics.