Protein adsorption and platelet attachment and activation, on TiN, TiC, and DLC coatings on titanium for cardiovascular applications.

The hemocompatibility of a TiN/TiC/diamond-like carbon (DLC) multilayer structure, deposited on titanium substrates for use as coatings for a heart valve prosthesis, has been studied through the adsorption of blood proteins and the adhesion and attachment of blood platelets. All of the surfaces were characterized by stylus profilometry and water contact angles. The adsorption of albumin and fibrinogen to the surfaces was assessed using the Amido Black assay, whereas platelet attachment was studied by scanning electron microscopy and quantified using stereological techniques. The degree of platelet spreading on the surfaces was seen to correlate with differences in surface energy, indicated from contact angle measurements. The greatest spreading was seen on the more hydrophilic surfaces. When studying protein adsorption to the surfaces, no correlation could be determined between contact angle results and levels of adsorption, although the most hydrophilic surfaces did appear to promote greater amounts of fibrinogen adsorption. Thrombus formation was observed to some degree on all of the surfaces, with the exception of the DLC coating. This coating also promoted less spreading of platelets than the other surfaces. The good hemocompatibility of the DLC coating is attributed to its hydrophobicity and smooth surface, resulting in a higher ratio of albumin to fibrinogen than any of the other surfaces.

[1]  B. Meenan,et al.  Properties of diamond like carbon thin film coatings on stainless steel medical guidewires , 1996 .

[2]  Jagdish Narayan,et al.  Diamond, diamond-like and titanium nitride biocompatible coatings for human body parts , 1994 .

[3]  D. Dowling,et al.  Diamond-Like Carbon Coatings for Biomedical Applications , 1995 .

[4]  I. R. McColl,et al.  The biocompatibility of low temperature diamond-like carbon films: a transmission electron microscopy, scanning electron microscopy and cytotoxicity study , 1994 .

[5]  N. Creugers,et al.  Titanium nitride coatings in clinical dentistry. , 1992, Journal of dentistry.

[6]  J. Lankford,et al.  Adherence of diamondlike carbon coatings on total joint substrate materials , 1993 .

[7]  S. Goodman,et al.  Platelet interaction with pyrolytic carbon heart-valve leaflets. , 1996, Journal of biomedical materials research.

[8]  I. R. McColl,et al.  Low temperature plasma-assisted chemical vapour deposition of amorphous carbon films for biomedical-polymeric substrates , 1994 .

[9]  J. Zak,et al.  Comparison of the surface structure of carbon films deposited by different methods , 1997 .

[10]  C. Baquey,et al.  Hemocompatibility of Titanium Nitride , 1992, The International journal of artificial organs.

[11]  P J Gregson,et al.  Application of PVD TiN coating to Co-Cr-Mo based surgical implants. , 1987, Biomaterials.

[12]  P. Havlík,et al.  Physico-chemistry and cytotoxicity of ceramics , 1994 .

[13]  O. Knotek,et al.  Physical vapour deposition coatings for dental prostheses , 1992 .

[14]  Y. Nosé,et al.  COMPARISON OF PROTEIN ADSORPTION AND PLATELET ADHESION ON THE SURFACE OF OXYGENATOR MEMBRANES , 1997 .

[15]  P. Louda,et al.  Diamond-like carbon coatings for biomedical applications , 1994 .

[16]  J. Eades Zone-axis diffraction patterns by the “Tanaka” method , 1984 .

[17]  H. Schnittler,et al.  A simple assay for quantification of protein in tissue sections, cell cultures, and cell homogenates, and of protein immobilized on solid surfaces , 1997, Cell and Tissue Research.

[18]  D. Teer,et al.  Deposition of wear resistant coatings based on diamond like carbon by unbalanced magnetron sputtering , 1993 .

[19]  N. Rushton,et al.  The effects of diamond-like carbon coatings on macrophages, fibroblasts and osteoblast-like cells in vitro. , 1994, Clinical materials.

[20]  Kouichi Naoi,et al.  Deposition of a diamond-like carbon film on a stainless steel substrate: studies of intermediate layers , 1991 .

[21]  I. R. McColl,et al.  Plasma assisted CVD for biomedical applications , 1992 .

[22]  I. R. McColl,et al.  Haemocompatibility of DLC and TiC–TiN interlayers on titanium , 1999 .

[23]  N. Rushton,et al.  Biocompatibility of diamond-like carbon coating. , 1991, Biomaterials.

[24]  M. Braun,et al.  Residual stress and microhardness of DLC multilayer coatings , 1996 .

[25]  W Zingg,et al.  Protein adsorption to polymer particles: role of surface properties. , 1987, Journal of biomedical materials research.

[26]  E Okamoto,et al.  Development of a Fine Ceramic Heart Valve for Use as a Cardiac Prosthesis , 1986, ASAIO transactions.

[27]  P. Niedzielski,et al.  Amorphous carbon — Biomaterial for implant coatings , 1994 .

[28]  A. Lunk,et al.  Biocompatibility of TiN preclinical and clinical investigations , 1991 .

[29]  J. C. Martin,et al.  Biocompatibility and corrosion resistance in biological media of hard ceramic coatings sputter deposited on metal implants , 1991 .

[30]  M. Hashmi,et al.  Magnetron sputtering of tin protective coatings for medical applications , 1996 .

[31]  P. Havlík,et al.  Cora rotary pump for implantable left ventricular assist device: biomaterial aspects. , 1997, Artificial organs.

[32]  I. R. McColl,et al.  A multilayer approach to high adhesion diamond-like carbon coatings on titanium , 1997 .

[33]  H. Nygren,et al.  Adsorption of coagulation proteins from whole blood on to polymer materials: relation to platelet activation. , 1992, Biomaterials.