Research on Control Strategy of Free-Piston Stirling Power Generating System

As a clean and fuel adaptive alternative power plant, the Stirling power generating system has drawn attention of experts and scholars in the energy field. In practical application, the instability of free-piston Stirling power generating system caused by abrupt load change is an inevitable problem. Thus, methods to improve the output frequency response and stability of the free-piston Stirling power generating system are necessary. The model of free-piston Stirling power generating system is built by isothermal analysis firstly, and the initial control strategy based on given voltage system is put forward. To further improve the performance of power system, a current feedback decoupling control strategy is proposed, and the mathematical model is established. The influence of full decoupled quadrature-direct (d-q) axis currents is analyzed with respect to the output voltage adjusting time and fluctuation amplitude under the variations of piston displacement and output load. The simulation results show that the system performance is significantly improved, but the dynamic regulation lags caused by the decoupled current control still exist. To solve this problem and improve the performance of decoupled-state feedback current control that relies on parameter accuracy, internal model control based on sliding mode (IMC-SM) current decoupling control strategy is proposed, the system model is established, and then the performance of voltage ripple in generating mode is improved. Finally, the test bench is built, and the steady state and transient voltage control performances are tested. The feasibility and priority of the control strategy is verified by experiment and simulation results.

[1]  Ping Zheng,et al.  Electromagnetic Design and Control Strategy of an Axially Magnetized Permanent-Magnet Linear Alternator for Free-Piston Stirling Engines , 2012, IEEE Transactions on Industry Applications.

[2]  Subir Roychoudhury,et al.  Progress Toward a Wearable 35 We Free-Piston Stirling Engine-based Soldier Power Source , 2006 .

[3]  J. Gary Wood,et al.  Free-Piston Stirling Power Conversion Unit for Fission Power System, Phase II Final Report , 2016 .

[4]  A. R. Tavakolpour-Saleh,et al.  A novel active free piston Stirling engine: Modeling, development, and experiment , 2017 .

[5]  D M Berchowitz,et al.  Linear Dynamics of Free-Piston Stirling Engines , 1985 .

[6]  Thomas J. Walter,et al.  5-kWe Free-piston Stirling Engine Convertor , 2008 .

[8]  Jeffrey G. Schreiber,et al.  A Historical Review of Brayton and Stirling Power Conversion Technologies for Space Applications , 2007 .

[9]  Salvatore M. Oriti,et al.  Processing and Preparation of Advanced Stirling Convertors for Extended Operation , 2008 .

[10]  Jeffrey G. Schreiber,et al.  Stirling System Modeling for Linear Dynamics Analysis , 2005 .

[11]  Kyle Wilson,et al.  Sunpower Implementation of Advanced Stirling Convertor Quality Management System , 2008 .

[12]  Raymond L. Kirby,et al.  Update on Development of a Control System for a 5 Kilowatt Free Piston Stirling Engine Convertor , 2008 .

[13]  Anthony Paul Roskilly,et al.  Design and simulation of a two- or four-stroke free-piston engine generator for range extender applications , 2016 .

[14]  Michal Šindelka Ensuring Steady Operation of Free-Piston Generator , 2013 .

[15]  Anne E. Garber Modifications to the Fission Surface Power Primary Test Circuit (FSP-PTC) , 2008 .

[16]  R. Mikalsen,et al.  The control of a free-piston engine generator. Part 2: Engine dynamics and piston motion control , 2010 .

[17]  A. R. Tavakolpour-Saleh,et al.  Neural network-based control of an intelligent solar Stirling pump , 2016 .

[18]  Necati Ulusoy Dynamic analysis of free piston Stirling engines , 1994 .

[19]  Ming Cheng,et al.  A Linear Stator Permanent Magnet Vernier HTS Machine for Wave Energy Conversion , 2012, IEEE Transactions on Applied Superconductivity.

[20]  Robert D. Lorenz,et al.  Performance of Feedforward Current Regulators for Field-Oriented Induction Machine Controllers , 1987, IEEE Transactions on Industry Applications.

[21]  Z. Yuenan,et al.  A speed calculation method for induction motor based on voltage decoupling control principle , 1997, Proceedings of Power Conversion Conference - PCC '97.

[22]  Ping Zheng,et al.  Research on control strategy of free-piston stirling-engine linear-generator system , 2014, 2014 17th International Conference on Electrical Machines and Systems (ICEMS).

[23]  Rodger W. Dyson,et al.  Towards Fully Three-Dimensional Virtual Stirling Convertors For Multi-Physics Analysis and Optimization , 2008 .

[24]  Scott S. Gerber,et al.  Advanced Controller for the Free-Piston Stirling Convertor , 2004 .

[25]  R. Mikalsen,et al.  The control of a free-piston engine generator. Part 1: Fundamental analyses , 2010 .

[26]  Ping Zheng,et al.  Analysis and Optimization of a Novel Tubular Staggered-Tooth Transverse-Flux PM Linear Machine , 2015, IEEE Transactions on Magnetics.

[27]  Shigeo Morimoto,et al.  Wide-speed operation of interior permanent magnet synchronous motors with high-performance current regulator , 1994 .

[28]  Z. Daboussi An inverter-based sensorless controller for free-piston Stirling engines , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[29]  Lee S. Mason,et al.  Overview of Multi-Kilowatt Free-Piston Stirling Power Conversion Research at Glenn Research Center , 2008 .