Development and characterization of a high-spatial-temporal-resolution foot-sole-pressure measurement system

Humans and biped robots generate unique pressure distributions under their feet while standing and walking. These foot pressure distributions are very vital information to analyze balance and walking in humans, and to analyze and control the gait cycles in robots. This research work involved development of a measurement system for measuring foot pressures using the Tekscan's F-Scan foot pressure sensor, characterization of the system and conducting some experiments to evaluate the system and introduce some statistical measures to characterize the pressure maps. The multiplexer and interface electronics were designed and the data acquisition system was built. Then the system characterization including the single sensor and whole sensor calibration was done. The spatial resolution of the F-Scan sensor is about 25 mm2, and the while scanning a single sensor element, the sampling time is about 0.3 ms, but sampling the complete sensor takes about 300 ms. So the issue is, there can be a trade-off between spatial and temporal resolution, reducing temporal resolution will increase spatial resolution and vice versa. The system was later evaluated using an in-house constructed simulation frame, which simulated the loading on an artificial leg, and generated unique pressure distributions for static and dynamic swaying of the leg. These pressure maps were analyzed using method of moments.

[1]  J. Woodburn,et al.  Observations on the F-Scan in-shoe pressure measuring system. , 1996, Clinical biomechanics.

[2]  Yoshio Tanimoto,et al.  The study of pressure distribution in sitting position on cushions for patient with SCI , 1998, IMTC/98 Conference Proceedings. IEEE Instrumentation and Measurement Technology Conference. Where Instrumentation is Going (Cat. No.98CH36222).

[3]  Stacy J. Morris,et al.  A shoe-integrated sensor system for wireless gait analysis and real-time therapeutic feedback , 2004 .

[4]  Hongwei Hsiao,et al.  Accuracy and precision of two in-shoe pressure measurement systems , 2002, Ergonomics.

[5]  N. J. Mills,et al.  Heel-shoe interactions and the durability of EVA foam running-shoe midsoles. , 2004, Journal of biomechanics.

[6]  L. Berglund,et al.  Validation of F-Scan pressure sensor system: a technical note. , 1998, Journal of rehabilitation research and development.

[7]  Guy Bessonnet,et al.  Forces acting on a biped robot. Center of pressure-zero moment point , 2004, IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans.

[8]  Ambarish Goswami,et al.  Postural Stability of Biped Robots and the Foot-Rotation Indicator (FRI) Point , 1999, Int. J. Robotics Res..

[9]  Jacob Fraden,et al.  Handbook of modern sensors , 1997 .

[10]  Alex Pentland,et al.  A sensing chair using pressure distribution sensors , 2001 .

[11]  F. A. Seiler,et al.  Numerical Recipes in C: The Art of Scientific Computing , 1989 .

[12]  B. Fregly,et al.  Estimation of discretization errors in contact pressure measurements. , 2003, Journal of biomechanics.

[13]  Y Suzuki,et al.  Sensing stability and dynamic response of the F-Scan in-shoe sensing system: a technical note. , 1998, Journal of rehabilitation research and development.

[14]  Yuan F. Zheng,et al.  Control of the heel off to toe off motion of a dynamic biped gait , 1991, Fifth International Conference on Advanced Robotics 'Robots in Unstructured Environments.

[15]  Guy Bessonnet,et al.  Gait analysis of a human walker wearing robot feet as shoes , 2001, Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (Cat. No.01CH37164).

[16]  Guy Bessonnet,et al.  Zero moment point-measurements from a human walker wearing robot feet as shoes , 2004, IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans.

[17]  W.J. Tompkins,et al.  An umbilical data-acquisition system for measuring pressures between the foot and shoe , 1990, IEEE Transactions on Biomedical Engineering.

[18]  S. Urry Plantar pressure-measurement sensors , 1999 .

[19]  Alison King,et al.  Flexible tactile sensor technology: bringing haptics to life , 2004 .

[20]  Martijn Wisse,et al.  A Three-Dimensional Passive-Dynamic Walking Robot with Two Legs and Knees , 2001, Int. J. Robotics Res..

[21]  J. Lima,et al.  A large area force sensor for smart skin applications , 2002, Proceedings of IEEE Sensors.

[22]  T. Izumi,et al.  Effects on the location of the centre of gravity and the foot pressure contribution to standing balance associated with ageing. , 1999, Ergonomics.