Incidence, retrieval methods, and outcomes of stent loss during percutaneous coronary intervention: A large single‐center experience

Our goal was to examine the incidence and consequences of stent loss during percutaneous coronary intervention (PCI) and the retrieval techniques used. We retrospectively reviewed 11,773 consecutive PCI cases involving stents performed at our institution between January 1994 and March 2004 to identify cases of stent loss. Stent loss occurred in 38 of 11,773 PCI procedures involving stents (0.32%; 95% CI = 0.23–0.44%). Mean age of the patients was 67 ± 11 years and 82% were men. Stent loss occurred more frequently in lesions with calcification and/or significant proximal angulation. In three patients, the stent was crushed and covered with another stent without attempting retrieval. Stent retrieval was attempted in 35 of 38 cases and was successful in 30 (86%). The following retrieval methods were used (more than one method was used in some cases): advancing a balloon through the stent, inflating the balloon, and withdrawing the stent (45%); twirling two wires around the stent (5%); loop snare (26%); biliary forceps (12%); Cook retained fragment retriever (10%); and basket retrieval device (2%). Patients in whom stent loss occurred had a higher incidence of bleeding requiring transfusion (24% vs. 7%; P < 0.001) and more often required emergency coronary artery bypass surgery (5% vs. 0.4%; P < 0.001). No patients in whom the stent was crushed or deployed in the coronary artery had any major cardiac complication. Stent loss during PCI occurs infrequently. Lost stents can be successfully retrieved in the majority of cases using a variety of retrieval techniques, yet stent loss is associated with an increased risk of complications. Stent deployment or crushing may be a good alternative to retrieval. © 2005 Wiley‐Liss, Inc.

[1]  Patrick W Serruys,et al.  Coronary-artery stents. , 2006, The New England journal of medicine.

[2]  A. Colombo Bifurcational lesions and the “crush” technique: Understanding why it works and why it doesn't—a kiss is not just a kiss , 2004, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[3]  M. Leesar,et al.  Novel implication of combined stent crushing and intravascular ultrasound for dislodged stents. , 2004, The Journal of invasive cardiology.

[4]  J. Tobis,et al.  Percutaneous snare retrieval of a partially embedded wallstent , 2004, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[5]  R. Prosst,et al.  Vascular Occlusion by Ruptured Balloon after Percutaneous Transluminal Angioplasty , 2003, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[6]  C. Di Mario,et al.  CORONARY ARTERY DISEASE Original Studies Modified T-Stenting Technique With Crushing for Bifurcation Lesions: Immediate Results and 30-Day Outcome , 2003 .

[7]  H. Kozman,et al.  Long-term outcome following coronary stent embolization or misdeployment. , 2001, The American journal of cardiology.

[8]  G. Laarman,et al.  Direct coronary stent implantation: Safety, feasibility, and predictors of success of the strategy of direct coronary stent implantation , 2001, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[9]  C von Birgelen,et al.  Nonsurgical retrieval of embolized coronary stents , 2000, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[10]  L. Klein,et al.  An unusual mechanism of coronary stent dislodgment and localization , 2000, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[11]  G. Mintz,et al.  Patience in the Pursuit of Perfection , 2000, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[12]  F. Hein,et al.  Removal of a ruptured, detached, and entrapped angioplasty balloon after coronary stenting. , 2000, The Journal of invasive cardiology.

[13]  R. Frankel,et al.  A technique to retrieve stents dislodged in the coronary artery followed by fixation in the iliac artery by means of balloon angioplasty and peripheral stent deployment , 2000, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[14]  Y. Yang,et al.  Successful retrieval of intracoronary lost balloon-mounted stent using a small balloon. , 2000, Chinese medical journal.

[15]  S. Jung,et al.  Dislodged stent: A simple retrieval technique , 1999, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[16]  B. Strauss,et al.  Failed coronary stent deployment. , 1998, American heart journal.

[17]  H. Douard,et al.  Successful retrieval of a lost coronary stent from the descending aorta using a loop basket intravascular retriever set. , 1998, Catheterization and cardiovascular diagnosis.

[18]  A. Farshid,et al.  Intracoronary embolization and retrieval of radio-opaque ring marker on the ACS Multi-Link stent sheath. , 1998, Catheterization and cardiovascular diagnosis.

[19]  W. Herzog,et al.  Deployment of a previously embolized, unexpanded, and disarticulated Palmaz-Schatz stent. , 1997, Catheterization and cardiovascular diagnosis.

[20]  E. Buffolo,et al.  Surgical retrieval of undeployed intracoronary stent without cardiopulmonary bypass. , 1997, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[21]  Bartorelli,et al.  Failure of Fluoroscopy and Success of Intravascular Ultrasound to Locate an Intracoronary Embolized Palmaz-Schatz Stent. , 1997, The Journal of invasive cardiology.

[22]  W. Kasper,et al.  Intracoronary loss of balloon-mounted stents: successful retrieval with a 2 mm-"Microsnare"-device. , 1996, Catheterization and cardiovascular diagnosis.

[23]  C. Macaya,et al.  Stent embolization during intracoronary stenting. , 1996, The American journal of cardiology.

[24]  S. Miyazaki,et al.  Successful retrieval of unexpanded Palmaz-Schatz stent from left main coronary artery. , 1996, Catheterization and cardiovascular diagnosis.

[25]  P. Wong Retrieval of undeployed intracoronary Palmaz-Schatz stents. , 1995, Catheterization and cardiovascular diagnosis.

[26]  M. Gotsman,et al.  Retrieval of occluding unexpanded Palmaz-Schatz stent from a saphenous aorto-coronary vein graft. , 1995, Catheterization and cardiovascular diagnosis.

[27]  H. R. Michels,et al.  Retrieval of undeployed stents from the right coronary artery: report of two cases. , 1993, Catheterization and cardiovascular diagnosis.

[28]  S. Higano,et al.  Retrieval techniques for managing flexible intracoronary stent misplacement. , 1993, Catheterization and cardiovascular diagnosis.

[29]  R. Gibbons,et al.  Outcome of noncardiac operations in patients with severe coronary artery disease successfully treated preoperatively with coronary angioplasty. , 1992, Mayo Clinic proceedings.

[30]  E J Topol,et al.  Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivessel coronary disease. Implications for patient selection. Multivessel Angioplasty Prognosis Study Group. , 1990, Circulation.