Comparison of Different Measurement Protocols in Electrical Capacitance Tomography Using Simulations

A major problem in electrical process tomography is that there exist relatively few measurement variables, as compared with the desired resolution of the reconstructed image. This, in addition to the ill-behaved inverse problem involved, makes the image reconstruction problem difficult and severely underdetermined. Using more complex measurement protocols, in addition to an increased number of electrodes, introduces smaller rotational steps of the electric field. More information about the material distribution is obtained, and an increase in the image fidelity may be expected. In this paper, the image fidelity using protocol 3 is compared with the results using the conventional protocol 1. In addition, some performance metrics to assess the fidelity of the protocols are used in the final stage of the analysis. The results are based on simulations using COMSOL Multiphysics and MATLAB.

[1]  William R B Lionheart EIT reconstruction algorithms: pitfalls, challenges and recent developments. , 2004, Physiological measurement.

[2]  Wuqiang Yang,et al.  Hardware design of electrical capacitance tomography systems , 1996 .

[3]  Wuqiang Yang,et al.  New AC-based capacitance tomography system , 1999 .

[4]  P. Hansen Rank-Deficient and Discrete Ill-Posed Problems: Numerical Aspects of Linear Inversion , 1987 .

[5]  Maurice Beck,et al.  Design of sensor electronics for electrical capacitance tomography , 1992 .

[6]  Ø. Isaksen,et al.  A review of reconstruction techniques for capacitance tomography , 1996 .

[7]  Tomasz Dyakowski,et al.  Direct flow-pattern identification using electrical capacitance tomography , 2002 .

[8]  Hua Yan,et al.  Simulation Study of Capacitance Tomography Sensors , 1999 .

[9]  Dieter Mewes,et al.  Recent developments and industrial/research applications of capacitance tomography , 1996 .

[10]  Roland Martin,et al.  Electrical capacitance tomography two-phase oil-gas pipe flow imaging by the linear back-projection algorithm , 2005 .

[11]  Trevor A. York,et al.  Status of electrical tomography in industrial applications , 2001, SPIE Optics East.

[12]  Wuqiang Yang,et al.  Development of capacitance tomographic imaging systems for oil pipeline measurements , 1995 .

[13]  Sanowar H. Khan,et al.  Finite element modelling of electrostatic fields in process tomography capacitive electrode systems for flow response evaluation , 1993 .

[14]  W. Heerens Application of capacitance techniques in sensor design , 1986 .

[15]  Brian S. Hoyle,et al.  Electrical capacitance tomography for flow imaging: system model for development of image reconstruction algorithms and design of primary sensors , 1992 .

[16]  Sharath Subash Donthi Capacitance based Tomography for Industrial Applications , 2004 .

[17]  Maurice Beck,et al.  Tomographic imaging of two-component flow using capacitance sensors , 1989 .

[18]  David Isaacson,et al.  Reconstructions of chest phantoms by the D-bar method for electrical impedance tomography , 2004, IEEE Transactions on Medical Imaging.

[19]  Wuqiang Yang,et al.  Optimization of an iterative image reconstruction algorithm for electrical capacitance tomography , 1999 .

[20]  Lihui Peng,et al.  Image reconstruction algorithms for electrical capacitance tomography , 2003 .

[21]  Malcolm Byars Developments in Electrical Capacitance Tomography , 2004 .

[22]  Sanowar H. Khan,et al.  Finite element modelling of multielectrode capacitive systems for flow imaging , 1993 .

[23]  Weifu Fang,et al.  A nonlinear image reconstruction algorithm for electrical capacitance tomography , 2004 .

[24]  Wuqiang Yang Further developments in an ac-based capacitance tomography system , 2001 .

[25]  Artur J. Jaworski,et al.  The design of an electrical capacitance tomography sensor for use with media of high dielectric permittivity , 2000 .

[26]  Manuchehr Soleimani,et al.  Nonlinear image reconstruction for electrical capacitance tomography using experimental data , 2005 .

[27]  Richard A Williams,et al.  Process Tomography: Principles, Techniques and Applications , 1995 .

[28]  Hermann A. Haus,et al.  Electromagnetic Fields And Energy , 1989 .

[29]  Gang Yang,et al.  Effect of Axial Guard Electrodes on Sensing Field of Capacitance Tomographic Sensor , 1999 .