Correlation Between Home INR and Core Laboratory INR in Patients Supported with Continuous-Flow Left Ventricular Assist Devices

It has been well established that patient self-testing (PST) of international normalized ratio (INR) using home monitoring devices increases the average therapeutic time and patient satisfaction. Long-term anticoagulation therapy with warfarin is used in patients with continuous-flow left ventricular assist device (CF-LVAD) to minimize the occurrence of thromboembolic events; however, PST devices have never been tested in patients with CF-LVADs. The purpose of this study was to determine the reliability of the PST device Alere INRatio 2 in patients supported with CF-LVADs. A correlation study was performed in 50 patients with CF-LVAD who were on stable warfarin therapy for a minimum of 3 weeks. Simultaneous INR values were determined from capillary whole blood samples using the Alere PST device and venous blood samples processed in the core laboratory at Columbia University Medical Center. There was a moderate correlation between the venous and the capillary INR values with a correlation coefficient of 0.83. The median difference between the methods was 0.39, with 44 of 50 patients recording higher INRs with Alere. Results remained unchanged after adjusting for use of amiodarone, abnormal hematocrit and liver enzymes, creatinine, and thyroid-stimulating hormone. Point of care testing with Alere correlates moderately well but consistently overestimates INR when compared with conventional laboratory testing in patients with CF-LVAD.

[1]  Patricia A. Ross,et al.  Pharmacist-Managed International Normalized Ratio Patient Self-Testing Is Associated with Increased Time in Therapeutic Range in Patients with Left Ventricular Assist Devices at an Academic Medical Center , 2014, ASAIO journal.

[2]  S. Russell,et al.  Algorithm for the diagnosis and management of suspected pump thrombus. , 2013, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[3]  A. La Gioia,et al.  Comparison of International Normalized Ratio Measurement between CoaguChek XS Plus and STA-R Coagulation Analyzers , 2012, BioMed research international.

[4]  Ranjit John,et al.  Bleeding and Thrombosis in Patients With Continuous-Flow Ventricular Assist Devices , 2012, Circulation.

[5]  T. Wilt,et al.  Meta-analysis: Effect of Patient Self-testing and Self-management of Long-Term Anticoagulation on Major Clinical Outcomes , 2011, Annals of Internal Medicine.

[6]  P. Lavori,et al.  Effect of home testing of international normalized ratio on clinical events. , 2010, The New England journal of medicine.

[7]  N. Uriel,et al.  Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation. , 2010, Journal of the American College of Cardiology.

[8]  S. Russell,et al.  Advanced heart failure treated with continuous-flow left ventricular assist device. , 2009, The New England journal of medicine.

[9]  A. Gallus,et al.  Accuracy and clinical usefulness of the CoaguChek S and XS Point of Care devices when starting warfarin in a hospital outreach setting. , 2009, Thrombosis research.

[10]  R. Poston,et al.  Anticoagulant monitoring in ventricular assist device patients: a feasibility study. , 2008, Interactive cardiovascular and thoracic surgery.

[11]  Christoph Benk,et al.  Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease. , 2008, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[12]  Jürgen Hennig,et al.  Three-dimensional magnetic resonance flow analysis in a ventricular assist device. , 2007, The Journal of thoracic and cardiovascular surgery.

[13]  D. J. Glatz,et al.  Self-Management of oral Anticoagulation in nonvalvular Atrial Fibrillation (SMAAF study) , 2005, Zeitschrift für Kardiologie.

[14]  Chris Gardiner,et al.  Patient self‐testing is a reliable and acceptable alternative to laboratory INR monitoring , 2005, British journal of haematology.

[15]  N. Uriel,et al.  Myocardial infarction after left ventricular assist device implantation: clinical course, role of aortic root thrombus, and outcomes. , 2014, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[16]  G. Ewald,et al.  Unexpected abrupt increase in left ventricular assist device thrombosis. , 2014, The New England journal of medicine.

[17]  M. Gold Effect of Home Testing of International Normalized Ratio on Clinical Events , 2011 .