Comparison of resonant current regulators for DFIG during grid voltage distortion

We investigate two different kinds of resonant current regulators for a doubly fed induction generator (DFIG) under distorted grid voltage conditions: proportional integral resonant (PIR) regulator with traditional resonant part and vector proportional integral (VPI) regulator with VPI resonant part. Based on the mathematical model of DFIG under distorted grid voltage, the transfer function and frequency response characteristics of the two current regulators are analyzed and compared. The superiority of the VPI current regulator over the PIR regulator is pointed out, and the influence of discretization methods on the performance of the resonant current regulator is studied. All the results are validated by MATLAB simulation and experiments.

[1]  Lie Xu,et al.  Dynamic Modeling and Control of DFIG-Based Wind Turbines Under Unbalanced Network Conditions , 2007, IEEE Transactions on Power Systems.

[2]  Ping Wang,et al.  Single-Loop Digital Control of High-Power 400-Hz Ground Power Unit for Airplanes , 2010, IEEE Transactions on Industrial Electronics.

[3]  F. Blaabjerg,et al.  High Performance Current Controller for Selective Harmonic Compensation in Active Power Filters , 2007, IEEE Transactions on Power Electronics.

[4]  Seddik Bacha,et al.  A Single Synchronous Frame Hybrid (SSFH) Multifrequency Controller for Power Active Filters , 2006, IEEE Transactions on Industrial Electronics.

[5]  H. Stemmler,et al.  Stationary frame generalized integrators for current control of active power filters with zero steady state error for current harmonics of concern under unbalanced and distorted operation conditions , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[6]  Rong Zeng,et al.  A three-phase programmable voltage sag generator for low voltage ride-through capability test of wind turbines , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[7]  Barry W. Williams,et al.  Improved Control of DFIG Systems During Network Unbalance Using PI–R Current Regulators , 2009, IEEE Transactions on Industrial Electronics.

[8]  Girish Kumar Singh,et al.  Power system harmonics research: a survey , 2009 .

[9]  Barry W. Williams,et al.  Predictive Current Control of Doubly Fed Induction Generators , 2009, IEEE Transactions on Industrial Electronics.

[10]  Frede Blaabjerg,et al.  Frequency Response Analysis of Current Controllers for Selective Harmonic Compensation in Active Power Filters , 2009, IEEE Transactions on Industrial Electronics.

[11]  R. W. De Doncker,et al.  Doubly fed induction generator systems for wind turbines , 2002 .

[12]  Donald Grahame Holmes,et al.  Stationary frame current regulation of PWM inverters with zero steady-state error , 2003 .

[13]  Wlodzimierz Koczara,et al.  DFIG-Based Power Generation System With UPS Function for Variable-Speed Applications , 2008, IEEE Transactions on Industrial Electronics.

[14]  Alvaro Luna,et al.  Simplified Modeling of a DFIG for Transient Studies in Wind Power Applications , 2011, IEEE Transactions on Industrial Electronics.

[15]  Ryota Imamura,et al.  Application of a sinusoidal internal model to current control of three-phase utility-interface converters , 2005, IEEE Transactions on Industrial Electronics.

[16]  Heng Nian,et al.  Direct Power Control of Doubly Fed Induction Generator Under Distorted Grid Voltage , 2014, IEEE Transactions on Power Electronics.

[17]  Heng Nian,et al.  Dynamic Modeling and Improved Control of DFIG Under Distorted Grid Voltage Conditions , 2011, IEEE Transactions on Energy Conversion.

[18]  Dehong Xu,et al.  Stator Current Harmonic Control With Resonant Controller for Doubly Fed Induction Generator , 2012, IEEE Transactions on Power Electronics.

[19]  Jason Yon,et al.  Design study of a three-phase brushless exciter for aircraft starter/generator , 2011, 2011 IEEE Energy Conversion Congress and Exposition.

[20]  Manel Jebali-Ben Ghorbal,et al.  Direct Virtual Torque Control for Doubly Fed Induction Generator Grid Connection , 2009, IEEE Transactions on Industrial Electronics.

[21]  Roberto Cárdenas,et al.  Control of a Doubly Fed Induction Generator via an Indirect Matrix Converter With Changing DC Voltage , 2011, IEEE Transactions on Industrial Electronics.

[22]  Jiabing Hu,et al.  Reinforced Control and Operation of DFIG-Based Wind-Power-Generation System Under Unbalanced Grid Voltage Conditions , 2009, IEEE Transactions on Energy Conversion.

[23]  G. Griva,et al.  Improved current control strategy for power conditioners using sinusoidal signal integrators in synchronous reference frame , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[24]  F. Profumo,et al.  Current control strategy for power conditioners using sinusoidal signal integrators in synchronous reference frame , 2005, IEEE Transactions on Power Electronics.

[25]  A.P. Martins,et al.  Rotor Current Controller with Voltage Harmonics Compensation for a DFIG Operating under Unbalanced and Distorted Stator Voltage , 2007, IECON 2007 - 33rd Annual Conference of the IEEE Industrial Electronics Society.

[26]  Lie Xu,et al.  Improved rotor current control of wind turbine driven doubly-fed induction generators during network voltage unbalance , 2010 .

[27]  S. Fukuda,et al.  Application of a sinusoidal internal model to current control of three-phase utility interface converters , 2005 .

[28]  Jano Malvar,et al.  Effects of Discretization Methods on the Performance of Resonant Controllers , 2010, IEEE Transactions on Power Electronics.

[29]  Dehong Xu,et al.  DC-Voltage Fluctuation Elimination Through a DC-Capacitor Current Control for DFIG Converters Under Unbalanced Grid Voltage Conditions , 2013, IEEE Transactions on Power Electronics.