A computational model of an improved cooling radiant ceiling panel system for optimization and design

Abstract Radiant cooling system comes to the foreground recently due to its improved thermal comfort and energy saving potential. However, surface condensation is still an unsolved problem and hinders the application of radiant cooling systems especially in hot and humid areas. An inside air layer was introduced to the improved cooling radiant ceiling panel (CRCP) system to achieve uniform temperature distribution on panel surface and reduce water condensation risk. A computational model for heat transfer analysis of the improved CRCP system was established and verified with experiment. The effects of the thickness of aluminum sheets, cooling panels and air layer, as well as the diameter and spacing of copper pipes on cooling capacity of the new system are studied. It is shown that the cooling capacity increases with thicker aluminum sheet and thicker radiant panel but thinner air layer. A thickness of 4.0–5.0 mm for the cooling panels is recommended to achieve a uniform surface temperature distribution according to numerical simulations. Besides, copper pipes with small diameter and thin plastic join are both beneficial to system performance. This study also provides a method to evaluate the maximum temperature difference and lowest surface temperature of the whole cooling panel, as well as a simple design chart for the improved CRCP system. Moreover, it is feasible to enhance the flow disturbance in air layer to improve heat transfer between the aluminum sheets and cooling panels, which can contribute to the savings of initial investment by using less pipe materials in CRCP.

[1]  Xu Zhang,et al.  Effects of radiant terminal and air supply terminal devices on energy consumption of cooling load sharing rate in residential buildings , 2012 .

[2]  D. Torvi,et al.  Testing and modelling of a novel ceiling panel for maintaining space relative humidity by moisture transfer , 2010 .

[3]  Ruzhu Wang,et al.  Experimental investigation on the heat transfer performance and water condensation phenomenon of radiant cooling panels , 2014 .

[4]  Toshiaki Omori,et al.  Thermal comfort and energy consumption of the radiant ceiling panel system.: Comparison with the conventional all-air system , 1999 .

[5]  Hansjürg Leibundgut,et al.  Evaluation of the humidity performance of a novel radiant cooling system connected with an Airbox convector as a low exergy system adapted to hot and humid climates , 2014 .

[6]  Youming Chen,et al.  Cooling capacity improvement for a radiant ceiling panel with uniform surface temperature distribution , 2016 .

[7]  Hansjürg Leibundgut,et al.  Thermal comfort and IAQ analysis of a decentralized DOAS system coupled with radiant cooling for the tropics , 2014 .

[8]  Kwang Woo Kim,et al.  A 50 year review of basic and applied research in radiant heating and cooling systems for the built environment , 2015 .

[9]  Jianlei Niu,et al.  Indoor humidity behaviors associated with decoupled cooling in hot and humid climates , 2003 .

[10]  Hanqing Wang,et al.  Numerical analysis of temperature non-uniformity and cooling capacity for capillary ceiling radiant cooling panel , 2016 .

[11]  Stanley A. Mumma,et al.  Simplified cooling capacity estimation model for top insulated metal ceiling radiant cooling panels , 2004 .

[12]  Jing Wu,et al.  Three dimensional temperature field of thermoelectric radiant panel system: Analytical modeling and experimental validation , 2017 .

[13]  Jing Wu,et al.  Thermal performance evaluation of an active building integrated photovoltaic thermoelectric wall system , 2016 .

[14]  Andreas K. Athienitis,et al.  Convective Heat Transfer Coefficients in a Building-Integrated Photovoltaic/Thermal System , 2011 .

[15]  Zhongbing Liu,et al.  Modeling and simulation of a photovoltaic thermal-compound thermoelectric ventilator system , 2018, Applied Energy.

[16]  Doosam Song,et al.  Possibility of coupling outdoor air cooling and radiant floor cooling under hot and humid climate conditions , 2014 .

[17]  Jian-Sheng Huang,et al.  Evaluation of cooling ceiling and mechanical ventilation systems on thermal comfort using CFD study in an office for subtropical region , 2012 .

[18]  Long Yun,et al.  An Experimental Research on Wall Radiant Cooling and Wall-Attached-Jet Air-Conditioning System , 2014 .

[19]  Mats Sandberg,et al.  The effect of false ceiling on the cooling capacity of passive chilled beams , 2009 .

[20]  Jianlei Niu,et al.  Indoor climate in rooms with cooled ceiling systems , 1994 .

[21]  Francesco Borrelli,et al.  Model predictive control of radiant slab systems with evaporative cooling sources , 2015 .

[22]  M. Pinar Mengüç,et al.  Thermal Radiation Heat Transfer , 2020 .

[23]  Fu Xiao,et al.  Neural network based prediction method for preventing condensation in chilled ceiling systems , 2012 .

[24]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[25]  Surapong Chirarattananon,et al.  A Field Study of Experimental of Radiant Cooling for Residential Building in a Tropical Climate , 2014 .

[26]  Zhe Zhang,et al.  Evaluation of thermal comfort criteria of an active chilled beam system in tropical climate: A comparative study , 2018, Building and Environment.

[27]  Limei Shen,et al.  The optimization design and parametric study of thermoelectric radiant cooling and heating panel , 2017 .

[28]  Wenjian Cai,et al.  Heat source effects on thermal comfort for active chilled beam systems , 2018, Building and Environment.

[29]  Wufeng Jin,et al.  The moisture content distribution of a room with radiant ceiling cooling and wall-attached jet system , 2017 .

[30]  Fariborz Haghighat,et al.  A procedure for calculating thermal response factors of multi-layer walls—State space method , 1991 .

[31]  Jelena Srebric,et al.  A critical review on the performance and design of combined cooled ceiling and displacement ventilation systems , 2002 .

[32]  Lei Xie,et al.  Modeling of the surface temperature field of a thermoelectric radiant ceiling panel system , 2016 .

[33]  Hansjürg Leibundgut,et al.  Advanced Airbox cooling and dehumidification system connected with a chilled ceiling panel in series adapted to hot and humid climates , 2014 .

[34]  Per Heiselberg,et al.  Sensitivity analysis of the thermal performance of radiant and convective terminals for cooling buildings , 2014 .

[35]  Guoqing Yu,et al.  Simplified model and performance analysis for top insulated metal ceiling radiant cooling panels with serpentine tube arrangement , 2018 .

[36]  Zhongbing Liu,et al.  Review of energy conservation technologies for fresh air supply in zero energy buildings , 2019, Applied Thermal Engineering.

[37]  Jing Wu,et al.  Dynamic heat transfer modeling and parametric study of thermoelectric radiant cooling and heating panel system , 2016 .

[38]  Rizwan Ahmed Memon,et al.  Thermal comfort assessment and application of radiant cooling : A case study , 2008 .

[39]  Hansjürg Leibundgut,et al.  A case study on feasible performance of a system combining an airbox convector with a radiant panel for tropical climates , 2014 .

[40]  S. Rees,et al.  An experimental study of air flow and temperature distribution in a room with displacement ventilation and a chilled ceiling , 2013 .

[41]  Angela Lee,et al.  The impact of occupants’ behaviours on building energy analysis: A research review , 2017 .