Optimization of LSO/LuYAP phoswich detector for small animal PET

Abstract LSO/LuYAP phoswich detectors for small animal PET were developed to measure the depth of interaction (DOI), and to improve the spatial resolution at the edge of the field of view (FOV). The aim of this study was to optimize the optical coupling conditions between the crystal and photomultiplier tube (PMT) to maximize the light-collection efficiency, and to develop a method for rejecting scatter events by applying an equal energy window in each crystal layer. The light yields of the phoswich detector were estimated by changing the refractive index of the optical coupling material using a DETECT simulation. The accuracy of the DOI measurement on the phoswich detector, using an optical coupling material with the optimal light yield, were evaluated experimentally and compared with the air condition. The energy window for the photopeak events cannot be applied properly because the light outputs of LSO and LuYAP are different. The LSO/LuYAP photopeaks need to be superposed in order to effectively discriminate the scattered events by applying an equal energy window. The photopeaks of the LSO and LuYAP can be superposed by inserting a reflecting material between the crystals. The optimal coverage ratio of the inserting material was derived from a DETECT simulation, and its performance was investigated. In the simulation result, optimal refractive index of the optical coupling material was 1.7. The average DOI measurement errors of the LSO/LuYAP were 0.6%/3.4% and 4.9%/41.4% in the phoswich detector with and without an optical coupling material, respectively. The photopeaks of the LSO and LuYAP were superposed by covering 75% of the contact surface between the crystals with white Teflon. The DOI measurement errors of the LSO/LuYAP were 0.2%/2.4%. In this study, the optimal condition of the optical coupling material inserted between the crystal and PMT was derived to improve the accuracy of DOI measurement, and a photopeak superposition method of the LSO and LuYAP was developed in order to reject scatter events.

[1]  J. G. Rogers,et al.  A practical block detector for a depth encoding PET camera , 1995 .

[2]  S. Cherry,et al.  A high efficiency pixelated detector for small animal PET , 2003, IEEE Transactions on Nuclear Science.

[3]  C Lartizien,et al.  GATE: a simulation toolkit for PET and SPECT. , 2004, Physics in medicine and biology.

[4]  Thomas K. Lewellen,et al.  Design of a depth of interaction (DOI) PET detector module , 1997 .

[5]  Uwe Pietrzyk,et al.  Design optimization of the PMT-ClearPET prototypes based on simulation studies with GEANT3 , 2002 .

[6]  Michael V. Green,et al.  Depth identification accuracy of a three layer phoswich PET detector module , 1999 .

[7]  S. Cherry,et al.  Performance evaluation of microPET: a high-resolution lutetium oxyorthosilicate PET scanner for animal imaging. , 1999, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  C.M. Pepin,et al.  Assessment of reflective separator films for small crystal arrays , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[9]  Gyuseong Cho,et al.  Characterization of dual layer phoswich detector performance for small animal PET using Monte Carlo simulation. , 2004, Physics in medicine and biology.

[10]  M. Montecchi,et al.  Study of some optical glues for the Compact Muon Solenoid at the Large Hadron Collider of CERN , 2001 .

[11]  P. Lecoq,et al.  Scintillation properties of mixed LuYAP crystals in view of their use in a small animal PET scanner in phoswich configuration , 2003 .

[12]  James F. Young,et al.  MicroPET: a high resolution PET scanner for imaging small animals , 1996, IEEE Nuclear Science Symposium Conference Record.

[13]  Carole Lartizien,et al.  The ClearPET ™ LSO/LuYAP Phoswich Scanner: A high Performance Small Animal PET System , 2004 .

[14]  Horst Halling,et al.  Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET , 2002 .

[15]  Ignace Lemahieu,et al.  Monte Carlo simulations of a scintillation camera using GATE: validation and application modelling. , 2003, Physics in medicine and biology.

[16]  H. Murayama,et al.  Design of a depth of interaction detector with a PS-PMT for PET , 1999 .

[17]  P. Lecoq,et al.  The ClearPET/spl trade/ LSO/LuYAP phoswich scanner: a high performance small animal PET system , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).