Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation.

A 53-year-old woman who had undergone aortic valve replacement with a Starr-Edwards (S-E) valve (Model 1260) and open mitral commissurotomy 28 years previously was hospitalized with cardiac failure. Echocardiography showed mitral stenosis, mitral regurgitation, and a normally functioning S-E prosthesis. At reoperation, the mitral and aortic valves were replaced with St Jude bileaflet mechanical prostheses. Examination of the explanted S-E prosthesis revealed no structural abnormality other than lipid infiltration of the silastic ball.

[1]  L. Rudas,et al.  Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation. , 2004, Circulation journal : official journal of the Japanese Circulation Society.

[2]  O. Lund,et al.  Performance profile of the Starr-Edwards aortic cloth covered valve, track valve, and silastic ball valve. , 1999, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[3]  徹夫 高橋,et al.  術後21年目に, 再手術を要した僧帽弁位 Starr-Edwards ボール弁機能不全の一例 , 1995 .

[4]  J. Matloff,et al.  The St. Jude Medical valve. Experience with 1,000 cases. , 1994, The Journal of thoracic and cardiovascular surgery.

[5]  S. Aoyagi,et al.  Long-term results of valve replacement with the St. Jude Medical valve. , 1994, The Journal of thoracic and cardiovascular surgery.

[6]  A. Tószegi,et al.  Lessons from the past: twenty-five years experience with the Cross-Jones caged disc prosthesis. , 1993, The Journal of heart valve disease.

[7]  E. Raanani,et al.  Late outcome of valve replacement with the Cross-Jones caged-lens prosthesis. , 1993, The Journal of heart valve disease.

[8]  G. Grunkemeier,et al.  Late ball variance with the Model 1000 Starr-Edwards aortic valve prosthesis. Risk analysis and strategy of operative management. , 1986, Journal of Thoracic and Cardiovascular Surgery.

[9]  W. Hemmer,et al.  Late (11 to 19 Years) Assessment of Hemodynamic and Prosthetic Valve Function in Patients with Starr Edwards Ball Valves: A Non-invasive Study Utilizing 99m-Technetium Pertechnetate Scintigraphy , 1985, The Thoracic and cardiovascular surgeon.

[10]  V. Fuster,et al.  Aortic and mitral valve incompetence: long-term follow-up (10 to 19 years) of patients treated with the Starr-Edwards prosthesis. , 1984, Journal of the American College of Cardiology.

[11]  F. Kloster,et al.  Changes in the durability of silicone rubber in ball-valve prostheses. , 1972, The Annals of thoracic surgery.

[12]  H. Griswold,et al.  Aortic Replacement: Clinical Experience with a Semirigid Ball‐Valve Prosthesis , 1963 .

[13]  A. Starr,et al.  Mitral Replacement: Clinical Experience with a Ball‐Valve Prosthesis , 1961, Annals of surgery.