Raman spectroscopy-based sensitive and specific detection of glycated hemoglobin.

In recent years, glycated hemoglobin (HbA1c) has been increasingly accepted as a functional metric of mean blood glucose in the treatment of diabetic patients. Importantly, HbA1c provides an alternate measure of total glycemic exposure due to the representation of blood glucose throughout the day, including post-prandially. In this article, we propose and demonstrate the potential of Raman spectroscopy as a novel analytical method for quantitative detection of HbA1c, without using external dyes or reagents. Using the drop coating deposition Raman (DCDR) technique, we observe that the nonenzymatic glycosylation (glycation) of the hemoglobin molecule results in subtle but discernible and highly reproducible changes in the acquired spectra, which enable the accurate determination of glycated and nonglycated hemoglobin using standard chemometric methods. The acquired Raman spectra display excellent reproducibility of spectral characteristics at different locations in the drop and show a linear dependence of the spectral intensity on the analyte concentration. Furthermore, in hemolysate models, the developed multivariate calibration models for HbA1c show a high degree of prediction accuracy and precision--with a limit of detection that is a factor of ~15 smaller than the lowest physiological concentrations encountered in clinical practice. The excellent accuracy and reproducibility achieved in this proof-of-concept study opens substantive avenues for characterization and quantification of the glycosylation status of (therapeutic) proteins, which are widely used for biopharmaceutical development. We also envision that the proposed approach can provide a powerful tool for high-throughput HbA1c sensing in multicomponent mixtures and potentially in hemolysate and whole blood lysate samples.

[1]  P. Prem Kiran,et al.  Laser-induced breakdown spectroscopy-based investigation and classification of pharmaceutical tablets using multivariate chemometric analysis. , 2011, Talanta.

[2]  Zoya I. Volynskaya,et al.  Raman spectroscopy: a real-time tool for identifying microcalcifications during stereotactic breast core needle biopsies , 2011, Biomedical optics express.

[3]  Marek Procházka,et al.  Drop‐coating deposition Raman spectroscopy of liposomes , 2011 .

[4]  Michael S. Feld,et al.  Combined confocal Raman and quantitative phase microscopy system for biomedical diagnosis , 2011, Biomedical optics express.

[5]  Michael S Feld,et al.  Wavelength selection-based nonlinear calibration for transcutaneous blood glucose sensing using Raman spectroscopy. , 2011, Journal of biomedical optics.

[6]  Royston Goodacre,et al.  Monitoring the glycosylation status of proteins using Raman spectroscopy. , 2011, Analytical chemistry.

[7]  Peter J Vikesland,et al.  Drop coating deposition Raman (DCDR) for microcystin-LR identification and quantitation. , 2011, Environmental science & technology.

[8]  R. Dasari,et al.  Investigation of the specificity of Raman spectroscopy in non-invasive blood glucose measurements , 2011, Analytical and bioanalytical chemistry.

[9]  Michael S Feld,et al.  Development of robust calibration models using support vector machines for spectroscopic monitoring of blood glucose. , 2010, Analytical chemistry.

[10]  Rohit Bhargava,et al.  Accurate histopathology from low signal-to-noise ratio spectroscopic imaging data. , 2010, The Analyst.

[11]  R. Dasari,et al.  Accurate spectroscopic calibration for noninvasive glucose monitoring by modeling the physiological glucose dynamics. , 2010, Analytical chemistry.

[12]  Ken-ichi Yoshida,et al.  Selective detection of HbA1c using surface enhanced resonance Raman spectroscopy. , 2010, Analytical chemistry.

[13]  Landulfo Silveira,et al.  ProRaman: a program to classify Raman spectra. , 2009, The Analyst.

[14]  Angela Man,et al.  Toward point-of-care diagnostic metabolic fingerprinting: quantification of plasma creatinine by infrared spectroscopy of microfluidic-preprocessed samples. , 2009, The Analyst.

[15]  David B Sacks,et al.  A new look at screening and diagnosing diabetes mellitus. , 2008, The Journal of clinical endocrinology and metabolism.

[16]  M. Morris,et al.  Effect of Conformation and Drop Properties on Surface-Enhanced Raman Spectroscopy of Dried Biopolymer Drops , 2008, Applied spectroscopy.

[17]  Qi Zhang,et al.  Increased serum glycated albumin level is associated with the presence and severity of coronary artery disease in type 2 diabetic patients. , 2007, Circulation journal : official journal of the Japanese Circulation Society.

[18]  N. Stone,et al.  Drop coating deposition Raman spectroscopy of protein mixtures. , 2007, The Analyst.

[19]  A. Materny,et al.  Nanostructured gold surfaces as reproducible substrates for surface‐enhanced Raman spectroscopy , 2007 .

[20]  Jaydeep Bhattacharya,et al.  Compensatory secondary structure alterations in protein glycation. , 2007, Biochimica et biophysica acta.

[21]  Vladimír Baumruk,et al.  Structure of the ring in drop coating deposited proteins and its implication for Raman spectroscopy of biomolecules , 2006 .

[22]  Dor Ben-Amotz,et al.  Validation of the drop coating deposition Raman method for protein analysis. , 2006, Analytical biochemistry.

[23]  R. Dasari,et al.  Diagnosing breast cancer by using Raman spectroscopy. , 2005, Proceedings of the National Academy of Sciences of the United States of America.

[24]  J Möcks,et al.  Comparison of mid-infrared and Raman spectroscopy in the quantitative analysis of serum. , 2005, Journal of biomedical optics.

[25]  Joseph Chaiken,et al.  Effect of hemoglobin concentration variation on the accuracy and precision of glucose analysis using tissue modulated, noninvasive, in vivo Raman spectroscopy of human blood: a small clinical study. , 2005, Journal of biomedical optics.

[26]  Abhay Sankar Chakraborti,et al.  Effect of nonenzymatic glycation on functional and structural properties of hemoglobin. , 2005, Biophysical chemistry.

[27]  Dor Ben-Amotz,et al.  Chemical Segregation and Reduction of Raman Background Interference Using Drop Coating Deposition , 2004, Applied spectroscopy.

[28]  Dor Ben-Amotz,et al.  Raman detection of proteomic analytes. , 2003, Analytical chemistry.

[29]  A. Booth,et al.  Unusual susceptibility of heme proteins to damage by glucose during non-enzymatic glycation. , 2003, Biophysical chemistry.

[30]  R. V. Van Duyne,et al.  Toward a glucose biosensor based on surface-enhanced Raman scattering. , 2003, Journal of the American Chemical Society.

[31]  M. Brownlee Biochemistry and molecular cell biology of diabetic complications , 2001, Nature.

[32]  Jack L. Koenig,et al.  Processing FT-IR Imaging Data for Morphology Visualization , 2000 .

[33]  D. Nathan,et al.  Immediate feedback of HbA1c levels improves glycemic control in type 1 and insulin-treated type 2 diabetic patients. , 1999, Diabetes care.

[34]  L. A. Currie,et al.  International recommendations offered on analytical detection and quantification concepts and nomenclature1“Contribution of the National Institute of Standards and Technology; not subject to copyright”.1 , 1999 .

[35]  G. Coté,et al.  The use of polarized laser light through the eye for noninvasive glucose monitoring. , 1999, Diabetes technology & therapeutics.

[36]  M A Arnold,et al.  Phantom glucose calibration models from simulated noninvasive human near-infrared spectra. , 1998, Analytical chemistry.

[37]  A. Fink,et al.  A new attenuated total reflectance Fourier transform infrared spectroscopy method for the study of proteins in solution. , 1998, Analytical biochemistry.

[38]  T. Dupont,et al.  Capillary flow as the cause of ring stains from dried liquid drops , 1997, Nature.

[39]  D. Goldstein,et al.  Endocrine (standardization of glycohemoglobin measurement). , 1995, Analytical chemistry.

[40]  H. Heise,et al.  Noninvasive blood glucose sensors based on near-infrared spectroscopy. , 1994, Artificial organs.

[41]  P. Roller,et al.  Secondary structure of proteins associated in thin films , 1993, Biopolymers.

[42]  D. Anderson,et al.  Determination of the lower limit of detection. , 1989, Clinical chemistry.

[43]  H. Mortensen,et al.  Glucosylation of human haemoglobin a in red blood cells studied in vitro. Kinetics of the formation and dissociation of haemoglobin A1c. , 1983, Clinica chimica acta; international journal of clinical chemistry.

[44]  M. Pézolet,et al.  Laser Raman investigation of the conformation of human immunoglobulin G. , 1976, Biochimica et biophysica acta.

[45]  A. Cerami,et al.  Correlation of glucose regulation and hemoglobin AIc in diabetes mellitus. , 1976, The New England journal of medicine.

[46]  V. Miskowski,et al.  Resonance Raman scattering from iron(3)- and copper(II)-transferrin and an iron(3) model compound. A spectroscopic interpretation of the transferrin binding site. , 1974, Journal of the American Chemical Society.

[47]  R. Mendelsohn,et al.  Laser-excited raman spectroscopy of biomolecules. III. Native bovine serum albumin and β-lactoglobulin , 1972 .

[48]  S. Rahbar An abnormal hemoglobin in red cells of diabetics. , 1968, Clinica chimica acta; international journal of clinical chemistry.