An integrated wearable robot for tremor suppression with context aware sensing

Tremor is a neurological disorder which can significantly impede the daily functions of patients. The available treatments for patients with tremor are mainly pharmacotherapy and neurosurgery, but these treatments often have side effects. A wearable exoskeleton can potentially provide the assistance needed for patients with Parkinsonian or essential tremor to carry out daily activities and enable independent living. This paper presents the design and development of a 3D printed lightweight tremor suppression wearable exoskeleton. One of the major technical challenges for wearable robot is to maintain long battery life meanwhile miniature in size for practical use. This paper proposes an integrated approach where context aware Body Sensor Networks (BSN) sensors are incorporated to characterize voluntary and tremor movement, and detect activities of daily life (ADL). With the contextual information, the system can determine the intention of the user, optimize its control and minimize its power consumption by providing the necessary suppression only when needed. The preliminary result has shown that the wearable robot prototype can reduce the amplitude of simulated tremor by around 77%, and accurately identify different ADL with accuracy above 70%.

[1]  Cameron N. Riviere,et al.  Design and implementation of active error canceling in hand-held microsurgical instrument , 2001, Proceedings 2001 IEEE/RSJ International Conference on Intelligent Robots and Systems. Expanding the Societal Role of Robotics in the the Next Millennium (Cat. No.01CH37180).

[2]  R. N. Stiles,et al.  Mechanical factors in human tremor frequency. , 1967, Journal of applied physiology.

[3]  Thierry Keller,et al.  Electrical stimulation for the suppression of pathological tremor , 2011, Medical & Biological Engineering & Computing.

[4]  Jing Zhang,et al.  DSP controller based signal processing of physiological hand tremor , 2005, Proceedings of the 2005, American Control Conference, 2005..

[5]  M. Topping,et al.  Dynamically responsive intervention for tremor suppression , 2003, IEEE Engineering in Medicine and Biology Magazine.

[6]  R. Elble,et al.  Mechanistic components of normal hand tremor. , 1978, Electroencephalography and clinical neurophysiology.

[7]  Suhail Kazi,et al.  Experimental implementation of smart glove incorporating piezoelectric actuator for hand tremor control , 2010 .

[8]  José Luis Pons Rovira,et al.  A soft wearable robot for tremor assessment and suppression , 2011, 2011 IEEE International Conference on Robotics and Automation.

[9]  Carlo Menon,et al.  On-Off Tremor Suppression Orthosis with Electromagnetic Brake , 2013 .

[10]  Elias Siores,et al.  Tremor Suppression Using Smart Textile Fibre Systems , 2009 .

[11]  M. Brin,et al.  Consensus Statement of the Movement Disorder Society on Tremor , 2008, Movement disorders : official journal of the Movement Disorder Society.

[12]  M J Rosen,et al.  A wearable tremor-suppression orthosis. , 1998, Journal of rehabilitation research and development.

[13]  H. Aziz Involuntary movements. , 1975, JPMA. The Journal of the Pakistan Medical Association.

[14]  David R Williams,et al.  My hands shake--classification and treatment of tremor. , 2009, Australian family physician.

[15]  L. Schwirtlich,et al.  Detection and prediction of FES-induced fatigue. , 1997, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[16]  José Luis Pons Rovira,et al.  Rehabilitation Robotics: a Wearable Exo-Skeleton for Tremor Assessment and Suppression , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[17]  L. Faes,et al.  Quantifying the contribution of arm postural tremor to the outcome of goal-directed pointing task by displacement measures , 2004, Journal of Neuroscience Methods.

[18]  Eduardo Rocon,et al.  Mechanical suppression of essential tremor , 2008, The Cerebellum.

[19]  E. Rocon,et al.  Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[20]  Cheng Yap Shee,et al.  Current progress on pathological tremor modelling and active compensation using functional electrical stimulation , 2008 .

[21]  Wei Tech Ang,et al.  Reciprocal EMG Controlled FES for Pathological Tremor Suppression of Forearm , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[22]  Keld West,et al.  Polypyrrole actuators working at 2–30 Hz , 2007 .

[23]  Mehmet Engin,et al.  A recording and analysis system for human tremor , 2007 .

[24]  Eduardo Rocon,et al.  Evaluation of a wearable orthosis and an associated algorithm for tremor suppression , 2007, Physiological measurement.

[25]  Eliana Della Flora,et al.  Deep brain stimulation for essential tremor: A systematic review , 2010, Movement disorders : official journal of the Movement Disorder Society.

[26]  Hideki Oshima,et al.  Difference in surgical strategies between thalamotomy and thalamic deep brain stimulation for tremor control , 2005, Journal of Neurology.

[27]  D. Case,et al.  Design and Characterization of a Small-Scale Magnetorheological Damper for Tremor Suppression , 2013, IEEE/ASME Transactions on Mechatronics.

[28]  Ian H. Witten,et al.  The WEKA data mining software: an update , 2009, SKDD.

[29]  S. Bruley des Varannes,et al.  Parkinson disease , 2011, Neurology.

[30]  Ryszard Tadeusiewicz,et al.  Acquisition and interpretation of upper limbs tremor signal in Parkinsonian disease , 2005 .

[31]  W. Koller,et al.  Tremor disorders. Diagnosis and management. , 1995, The Western journal of medicine.