Ultimate capacity of rectangular concrete-filled steel tubular columns under unequal load eccentricities

Abstract The paper describes 36 experimental tests conducted on rectangular and square tubular columns filled with normal and high strength concrete and subjected to a non-constant bending moment distribution with respect to the weak axis. The test parameters were the nominal strength of concrete (30 and 90 MPa), the cross-section aspect ratio (square or rectangular), the thickness (4 or 5 mm) and the ratio of the top and bottom first order eccentricities e top /e bottom (1, 0.5, 0 and − 0.5). The ultimate load of each test was compared with the design loads from Eurocode 4, presenting unsafe results inside a 10% safety margin. The tests show that the use of high strength concrete is more useful for the cases of non-constant bending moment, whereas if the aim is to obtain a more ductile behavior the use of concrete-filled columns is more appealing in the cases of normal strength concrete with non-constant bending moments because, although they resist less axial force than the members with HSC, they obtain a softened post-peak behavior.

[1]  Manuel L. Romero,et al.  Experimental study of high strength concrete-filled circular tubular columns under eccentric loading , 2011 .

[2]  M. Joyce,et al.  Strength of Eccentrically Loaded Slender Steel Tubular Columns Filled With High-Strength Concrete , 1992 .

[3]  Dong Keon Kim A Database for Composite Columns , 2005 .

[4]  K. F. Chung,et al.  Composite column design to Eurocode 4 : based on DD ENV 1994-1-1: 1994 Eurocode 4: design of composite steel and concrete structures: part 1.1: general rules and rules for buildings , 1994 .

[5]  Richard Sause,et al.  Experimental Behavior of High Strength Square Concrete-Filled Steel Tube Beam-Columns , 2002 .

[6]  Marianne Grauers,et al.  Composite Columns of Hollow Steel Sections Filled with High Strength Concrete , 1993 .

[7]  B. Vijaya Rangan,et al.  Tests on High-Strength Concrete-Filled Steel Tubular Columns , 1999 .

[8]  Yong Wang Tests on slender composite columns , 1999 .

[9]  Lin-Hai Han,et al.  Experimental behaviour of concrete-filled stiffened thin-walled steel tubular columns , 2007 .

[10]  Tsong Yen,et al.  Experimental study on rectangular CFT columns with high-strength concrete , 2007 .

[11]  Jie Yuan,et al.  Ultimate capacity of high-strength rectangular concrete-filled steel hollow section stub columns , 2003 .

[12]  D. A. Nethercot,et al.  Designer's guide to EN 1993-1-1 : Eurocode 3: Design of Steel Structures : General Rules and Rules for Buildings /L. Gardner and D. A. Nethercot , 2005 .

[13]  Zhong Tao,et al.  Experimental behaviour of high performance concrete-filled steel tubular columns , 2008 .

[14]  Kamel Chaoui,et al.  An experimental behaviour of concrete-filled steel tubular columns , 2005 .