Ocular Microtremor During General Anesthesia: Results of a Multicenter Trial Using Automated Signal Analysis

Ocular microtremor (OMT) is a fine physiologic tremor of the eye related to neuronal activity in the reticular formation of the brainstem. The frequency of OMT is suppressed by propofol and sevoflurane and predicts the response to command at emergence from anesthesia. Previous studies have relied on post hoc computer analysis of OMT wave forms or on real-time measurements confirmed visually on an oscilloscope. Our overall aim was to evaluate an automated system of OMT signal analysis in a diverse patient population undergoing general anesthesia. In a multicenter trial involving four centers in three countries, we examined the accuracy of OMT to identify the unconscious state and to predict movement in response to airway instrumentation and surgical stimulation. We also tested the effects of neuromuscular blockade and patient position on OMT. We measured OMT continuously by using the closed-eye piezoelectric technique in 214 patients undergoing extracranial surgery with general anesthesia using a variety of anesthetics. OMT decreased at induction in all patients, increased transiently in response to surgical incision or airway instrumentation, and increased at emergence. The frequency of OMT predicted movement in response to laryngeal mask airway insertion and response to command at emergence. Neuromuscular blockade did not affect the frequency of OMT but decreased its amplitude. OMT frequency was unaffected by changes in patient position. We conclude that OMT, measured by an automated signal analysis module, accurately determines the anesthetic state in surgical patients, even during profound neuromuscular blockade and after changes in patient position.

[1]  F. H. Adler,et al.  INFLUENCE OF FIXATION ON THE VISUAL ACUITY , 1934 .

[2]  E. Eger,et al.  Minimum alveolar anesthetic concentration: a standard of anesthetic potency. , 1965, Anesthesiology.

[3]  Davis Coakley,et al.  The ocular microtremor record as a potential procedure for establishing brain death , 1977, Journal of the Neurological Sciences.

[4]  J G Thomas,et al.  Micro-tremor of the eyes of comatose patients. , 1977, Electroencephalography and clinical neurophysiology.

[5]  Davis Coakley,et al.  THE OCULAR MICROTREMOR RECORD AND THE PROGNOSIS OF THE UNCONSCIOUS PATIENT , 1977, The Lancet.

[6]  W. B. Cushman,et al.  The precision of gaze. A review. , 1982, Human neurobiology.

[7]  R M Steinman,et al.  The precision of gaze. A review. , 1982 .

[8]  P. E. Hallett,et al.  Power spectra for ocular drift and tremor , 1985, Vision Research.

[9]  I J Rampil,et al.  No correlation between quantitative electroencephalographic measurements and movement response to noxious stimuli during isoflurane anesthesia in rats. , 1992, Anesthesiology.

[10]  I J Rampil,et al.  Anesthetic Potency (MAC) Is Independent of Forebrain Structures in the Rat , 1993, Anesthesiology.

[11]  I J Rampil,et al.  The Electroencephalogram Does Not Predict Depth of Isoflurane Anesthesia , 1994, Anesthesiology.

[12]  N. T. Smith,et al.  A Multicenter Study of Bispectral Electroencephalogram Analysis for Monitoring Anesthetic Effect , 1997, Anesthesia and analgesia.

[13]  K. Ikeda,et al.  Electroencephalographic Derivatives as a Tool for Predicting the Depth of Sedation and Anesthesia Induced by Sevoflurane , 1998, Anesthesiology.

[14]  J. R. Rosenberg,et al.  The origin of ocular microtremor in man , 1999, Experimental Brain Research.

[15]  Bolger,et al.  Ocular microtremor in brain stem death , 1999, Neurosurgery.

[16]  C Bolger,et al.  Ocular microtremor in patients with idiopathic Parkinson’s disease , 1999, Journal of neurology, neurosurgery, and psychiatry.

[17]  C. Bolger,et al.  Ocular microtremor in oculomotor palsy. , 1999, Journal of neuro-ophthalmology : the official journal of the North American Neuro-Ophthalmology Society.

[18]  C. Pierrot-Deseilligny,et al.  Neurology of saccades and smooth pursuit. , 1999, Current opinion in neurology.

[19]  E Konecny,et al.  Middle latency auditory evoked responses and electroencephalographic derived variables do not predict movement to noxious stimulation during 1 minimum alveolar anesthetic concentration isoflurane/nitrous oxide anesthesia. , 1999, Anesthesia and analgesia.

[20]  C. Bolger,et al.  Dominant frequency content of ocular microtremor from normal subjects , 1999, Vision Research.

[21]  M. Doi,et al.  Prediction of movement at laryngeal mask airway insertion: comparison of auditory evoked potential index, bispectral index, spectral edge frequency and median frequency. , 1999, British journal of anaesthesia.

[22]  Davis Coakley,et al.  Ocular microtremor (OMT): a new neurophysiological approach to multiple sclerosis , 2000, Journal of neurology, neurosurgery, and psychiatry.

[23]  C. Bolger,et al.  Ocular microtremor: a tool for measuring depth of anaesthesia? , 2000, British journal of anaesthesia.

[24]  Lorri A. Lee,et al.  Unilateral blindness after prone lumbar spine surgery. , 2001, Anesthesiology.

[25]  G N Kenny,et al.  Auditory Evoked Potential Index Predicts the Depth of Sedation and Movement in Response to Skin Incision during Sevoflurane Anesthesia , 2001, Anesthesiology.

[26]  C. Hoyt Ocular microtremor (OMT): a new neurophysiological approach to multiple sclerosis, by C. Bolger, S. Bojanic, N. Sheahan, J. Malone, and D. Coakley. J Neurol Neurosurg Psychiatry 68:639-42, 2000. , 2001, Survey of ophthalmology.

[27]  P. Barach,et al.  Postoperative visual loss: still no answers--yet. , 2001, Anesthesiology.

[28]  C. Bolger,et al.  Comparison of ocular microtremor and bispectral index during sevoflurane anaesthesia. , 2002, British journal of anaesthesia.

[29]  T. Mizen Postoperative visual loss, still no answers yet. , 2003 .

[30]  D. Coakley,et al.  Ocular microtremor measurement system: Design and performance , 1993, Medical and Biological Engineering and Computing.

[31]  J. G. Thomas,et al.  Three electronic methods for recording ocular tremor , 2006, Medical and biological engineering.

[32]  P. Brown,et al.  Eye acceleration during large horizontal saccades in man , 2006, Experimental Brain Research.