Inaccuracy of wrist-cuff oscillometric blood pressure devices: an arm position artefact?

BackgroundDespite the increasing popularity of wrist-cuff blood pressure (BP) devices, their accuracy has not been established and international guidelines do not support their use. Because arm position influences BP measurement, it is possible that conflicting reports on wrist-cuff device accuracy reflects diverse arm positions. MethodThis study compared BP measured by two oscillometric devices, the upper arm-cuff OMRON HEM 705 CP and the OMRON R6 oscillometric wrist-cuff device. In the former BP was measured with the arm in two supported positions, dependent on a table (manufacturer's instructions) and horizontal (mid sternum), while the latter followed the manufacturer's instructions. ResultsIn contrast to the dependent arm where BP was significantly higher (P<0.05), the horizontal arm position with the arm-cuff produced a mean systolic and diastolic BP comparable to the wrist-cuff device where the wrist was at heart level being respectively, 137±29/80±16 and 134±27/77±16 mmHg. A close relationship over a wide BP range was also confirmed by least squares, least product linear regression and Bland–Altman analysis. ConclusionThis study supports the use of wrist-cuff monitors for self/home use and underlines the need for a more precise definition for arm position when using all BP devices – mercury and oscillometric.

[1]  R. Erbel,et al.  Wrist Measurement of Blood Pressure: Some Critical Remarks to Oscillometry , 1999, Kidney and Blood Pressure Research.

[2]  T. Pickering,et al.  Consensus Conference on Self-blood pressure measurement. Clinical applications and diagnosis. , 2000, Blood pressure monitoring.

[3]  Y. Imai,et al.  Prognostic significance of self-measurements of blood pressure. , 2000, Blood Pressure Monitoring.

[4]  T. Lüscher,et al.  Accuracy of a new wrist cuff oscillometric blood pressure device: comparisons with intraarterial and mercury manometer measurements. , 1998, American journal of hypertension.

[5]  Yutaka Imai,et al.  Accuracy and reliability of wrist-cuff devices for self-measurement of blood pressure , 2002, Journal of hypertension.

[6]  Paul Wieneke,et al.  Evaluation of the performance of a wrist blood pressure measuring device with a position sensor compared to ambulatory 24-hour blood pressure measurements. , 2002, American journal of hypertension.

[7]  R. Brook,et al.  Measurement variation among 12 electronic home blood pressure monitors. , 2000, American journal of hypertension.

[8]  V. Burke,et al.  COMPARISON OF OSCILLOMETRIC BLOOD PRESSURE MEASUREMENTS AT THE WRIST WITH AN UPPER‐ARM AUSCULTATORY MERCURY SPHYGMOMANOMETER , 1999, Clinical and experimental pharmacology & physiology.

[9]  J. Ludbrook SPECIAL ARTICLE COMPARING METHODS OF MEASUREMENT , 1997 .

[10]  S. Yarrows Hypertension articles in primary care journals. , 2000 .

[11]  F. Fruhwald,et al.  Comparison of wrist blood pressure measurement with conventional sphygmomanometry at a cardiology outpatient clinic , 2000, Journal of Hypertension.

[12]  D. Altman,et al.  Comparing methods of measurement: why plotting difference against standard method is misleading , 1995, The Lancet.

[13]  A. Mourad,et al.  Arm position and blood pressure: an audit , 2004, Internal medicine journal.

[14]  Bruce Neal,et al.  1999 World Health Organization-International Society of Hypertension Guidelines for the Management of Hypertension. Guidelines Subcommittee. , 1999, Journal of hypertension.

[15]  M. Maiwald,et al.  Patient assessment of self-measurement of blood pressure: results of a telephone survey in Germany , 1996, Journal of hypertension.

[16]  R. Netea,et al.  Influence of body and arm position on blood pressure readings: an overview. , 2003, Journal of Hypertension.

[17]  Yutaka Imai,et al.  European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement , 2003, Journal of hypertension.

[18]  L. Heinemann,et al.  A cross‐over evaluation of different methods and devices to measure blood pressure in type 1 diabetic patients with nephropathy , 2000, Blood pressure monitoring.

[19]  A. Mourad,et al.  Arm position and blood pressure: a risk factor for hypertension? , 2003, Journal of Human Hypertension.

[20]  F. Mee,et al.  Evaluation of three devices for self-measurement of blood pressure according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Philips HP5332, and Nissei DS-175. , 1996, Blood pressure monitoring.

[21]  A. C. Burton,et al.  Recommendations for Human Blood Pressure Determination By Sphygmomanometers , 1981, Circulation.