A Hermetic Wireless Subretinal Neurostimulator for Vision Prostheses

A miniaturized, hermetically encased, wirelessly operated retinal prosthesis has been developed for preclinical studies in the Yucatan minipig, and includes several design improvements over our previously reported device. The prosthesis attaches conformally to the outside of the eye and electrically drives a microfabricated thin-film polyimide array of sputtered iridium oxide film electrodes. This array is implanted into the subretinal space using a customized ab externo surgical technique. The implanted device includes a hermetic titanium case containing a 15-channel stimulator chip and discrete circuit components. Feedthroughs in the case connect the stimulator chip to secondary power and data receiving coils on the eye and to the electrode array under the retina. Long-term in vitro pulse testing of the electrodes projected a lifetime consistent with typical devices in industry. The final assembly was tested in vitro to verify wireless operation of the system in physiological saline using a custom RF transmitter and primary coils. Stimulation pulse strength, duration, and frequency were programmed wirelessly from a Peripheral Component Interconnect eXtensions for Instrumentation (PXI) computer. Operation of the retinal implant has been verified in two pigs for up to five and a half months by detecting stimulus artifacts generated by the implanted device.

[1]  Thomas Schanze,et al.  Implantation and testing of subretinal film electrodes in domestic pigs. , 2006, Experimental eye research.

[2]  S. Kelly,et al.  Methods and perceptual thresholds for short-term electrical stimulation of human retina with microelectrode arrays. , 2003, Investigative ophthalmology & visual science.

[3]  P. Jong Prevalence of age-related macular degeneration in the United States. , 2004 .

[4]  L.S. Theogarajan A Low-Power Fully Implantable 15-Channel Retinal Stimulator Chip , 2008, IEEE Journal of Solid-State Circuits.

[5]  Joseph F. Rizzo,et al.  Surgical Implantation of 1.5 Generation Retinal Implant in Minipig Eyes , 2010 .

[6]  H. Gerding,et al.  Experimental implantation of epiretinal retina implants (EPI-RET) with an IOL-type receiver unit , 2007, Journal of neural engineering.

[7]  Paul J DeMarco,et al.  Stimulation via a subretinally placed prosthetic elicits central activity and induces a trophic effect on visual responses. , 2007, Investigative ophthalmology & visual science.

[8]  R. Jensen,et al.  Responses of ganglion cells to repetitive electrical stimulation of the retina , 2007, Journal of neural engineering.

[9]  M. S. Humayun,et al.  Preliminary Results from Argus II Feasibility Study: A 60 Electrode Epiretinal Prosthesis , 2009 .

[10]  P. Preston,et al.  Retinal Neurostimulator for a Multifocal Vision Prosthesis , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[11]  Philip R. Troyk,et al.  In vitro comparison of the charge-injection limits of activated iridium oxide (AIROF) and platinum-iridium microelectrodes , 2005, IEEE Transactions on Biomedical Engineering.

[12]  W. A. Drohan,et al.  Realization of a 15-channel, hermetically-encased wireless subretinal prosthesis for the blind , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  P. Troyk,et al.  The influence of electrolyte composition on the in vitro charge-injection limits of activated iridium oxide (AIROF) stimulation electrodes , 2007, Journal of neural engineering.

[14]  M. Mladejovsky,et al.  ‘Braille’ reading by a blind volunteer by visual cortex stimulation , 1976, Nature.

[15]  Krista I Kinard,et al.  Neural reprogramming in retinal degeneration. , 2007, Investigative ophthalmology & visual science.

[16]  J. Loewenstein,et al.  Extraction of a Chronically Implanted, Microfabricated, Subretinal Electrode Array , 2009, Ophthalmic Research.

[17]  J. Weiland,et al.  Visual performance using a retinal prosthesis in three subjects with retinitis pigmentosa. , 2007, American journal of ophthalmology.

[18]  S. J. Kim,et al.  A Suprachoroidal Electrical Retinal Stimulator Design for Long-Term Animal Experiments and In Vivo Assessment of Its Feasibility and Biocompatibility in Rabbits , 2008, Journal of biomedicine & biotechnology.

[19]  G. Brindley,et al.  The sensations produced by electrical stimulation of the visual cortex , 1968, The Journal of physiology.

[20]  Benita J. O’Colmain,et al.  Prevalence of age-related macular degeneration in the United States. , 2004, Archives of ophthalmology.

[21]  J. Ohta,et al.  The development of a multichannel electrode array for retinal prostheses , 2006, Journal of Artificial Organs.

[22]  Joseph F Rizzo,et al.  In vivo electrical stimulation of rabbit retina: effect of stimulus duration and electrical field orientation. , 2006, Experimental eye research.

[23]  N.R. Srivastava,et al.  A laboratory testing and driving system for AIROF microelectrodes , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[24]  Joseph F. Rizzo,et al.  Development and Implantation of a Minimally Invasive Wireless Subretinal Neurostimulator , 2009, IEEE Transactions on Biomedical Engineering.

[25]  S. Kelly,et al.  Perceptual efficacy of electrical stimulation of human retina with a microelectrode array during short-term surgical trials. , 2003, Investigative ophthalmology & visual science.

[26]  R. Hornig,et al.  The IMI Retinal Implant System , 2007 .

[27]  Shawn Kevin Kelly A system for electrical retinal stimulation for human trials , 1998 .