Thorax: low-dose contrast-enhanced three-dimensional MR angiography with subsecond temporal resolution--initial results.

The purpose of the study was to implement a three-dimensional (3D) magnetic resonance (MR) angiographic technique with acquisition times on the order of 800 msec with use of a spoiled gradient-echo pulse sequence (repetition time, 1.60 msec; echo time, 0.65 msec) and bolus intravenous injection of contrast material doses as small as 6 mL. High-spatial-resolution conventional MR angiography performed with 30 mL of gadopentetate dimeglumine was the reference standard. As implemented, subsecond 3D MR angiography allowed temporal sampling that was rapid enough to depict short-lived processes, as illustrated in patients with shunts and dissections. With small contrast material doses and subsecond frame rates, it is also possible to measure pulmonary arteriovenous circulation times with this 3D MR angiographic technique.

[1]  S J Riederer,et al.  High-spatial-resolution contrast-enhanced MR angiography of the renal arteries: a prospective comparison with digital subtraction angiography. , 2001, Radiology.

[2]  T. Chenevert,et al.  Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches. , 1995, Radiology.

[3]  R F Busse,et al.  Three-dimensional contrast-enhanced MR angiography with real-time fluoroscopic triggering: design specifications and technical reliability in 330 patient studies. , 2000, Radiology.

[4]  T. Chenevert,et al.  Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography. , 1997, Radiology.

[5]  Gerhard Laub,et al.  MR angiography with gradient motion refocusing. , 1988 .

[6]  R. Wilson,et al.  Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution. , 1998, Medical physics.

[7]  P H Carey,et al.  A comparison of peak-to-peak pulmonary transit time determined by digital intravenous angiography with standard dye-dilution techniques in anesthetized dogs. , 1982, Investigative radiology.

[8]  J K Kim,et al.  Test bolus examination in the carotid artery at dynamic gadolinium-enhanced MR angiography. , 1998, Radiology.

[9]  Y. Wang,et al.  Breath-hold three-dimensional contrast-enhanced coronary MR angiography: motion-matched k-space sampling for reducing cardiac motion effects. , 2000, Radiology.

[10]  V B Ho,et al.  Thoracic MR aortography: imaging techniques and strategies. , 1998, Radiographics : a review publication of the Radiological Society of North America, Inc.

[11]  C. Higgins,et al.  Pulmonary circulation time: comparison of mean, median, peak, and onset (appearance) values using indocyanine green and first-transit radionuclide techniques. , 1983, American heart journal.

[12]  P. Douek,et al.  Dynamic contrast-enhanced MR angiography of pulmonary embolism: comparison with pulmonary angiography. , 1994, AJR. American journal of roentgenology.

[13]  P. Rehak,et al.  Noninvasive Measurement of Pulmonary Vascular Resistances by Assessment of Cardiac Output and Pulmonary Transit Time , 2000, Investigative radiology.

[14]  James C Carr,et al.  Gadolinium-enhanced 3D MR angiography of renal artery stenosis: a pilot comparison of maximum intensity projection, multiplanar reformatting, and 3D volume-rendering postprocessing algorithms. , 2002, Academic radiology.

[15]  J Hennig,et al.  Fast functional MRA using time‐resolved projection MR angiography with correlation analysis , 2000, Magnetic resonance in medicine.

[16]  U. Salvolini,et al.  MR angiography in carotid stenosis: a comparison of three techniques. , 1998, European journal of radiology.

[17]  M. Prince,et al.  Arterial-phase three-dimensional contrast-enhanced MR angiography of the carotid arteries. , 1996, AJR. American journal of roentgenology.

[18]  R Frayne,et al.  Time‐resolved contrast‐enhanced 3D MR angiography , 1996, Magnetic resonance in medicine.

[19]  Gerhard Laub,et al.  Contrast‐enhanced breath‐hold three‐dimensional magnetic resonance angiography in the evaluation of renal arteries: Optimization of technique and pitfalls , 2000, Journal of magnetic resonance imaging : JMRI.

[20]  P. Molina,et al.  Motion artifact simulating aortic dissection on CT. , 1991, AJR. American journal of roentgenology.

[21]  N M Rofsky,et al.  Thoracic aorta: comparison of gadolinium-enhanced three-dimensional MR angiography with conventional MR imaging. , 1997, Radiology.

[22]  Richard Frayne,et al.  3D Time‐resolved contrast‐enhanced MR DSA: Advantages and tradeoffs , 1998, Magnetic resonance in medicine.

[23]  R F Busse,et al.  Carotid arteries: maximizing arterial to venous contrast in fluoroscopically triggered contrast-enhanced MR angiography with elliptic centric view ordering. , 1999, Radiology.

[24]  C. Higgins,et al.  Analysis of the pulmonary circulation using digital intravenous angiography. , 1982, Radiology.

[25]  C. Nienaber,et al.  MRI of acute and chronic aortic pathology: Pre‐operative and postoperative evaluation , 1999, Journal of Magnetic Resonance Imaging.

[26]  S J Riederer,et al.  Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: application to the renal arteries. , 1997, Radiology.

[27]  T L Chenevert,et al.  Diagnosis of pulmonary embolism with magnetic resonance angiography. , 1997, The New England journal of medicine.

[28]  N. Rofsky,et al.  Thoracic aorta: comparison of single-dose breath-hold and double-dose non-breath-hold gadolinium-enhanced three-dimensional MR angiography. , 1999, AJR. American journal of roentgenology.

[29]  G G Hartnell,et al.  Imaging of Aortic Aneurysms and Dissection: CT and MRI , 2001, Journal of thoracic imaging.

[30]  M. Alley,et al.  Partial fat-saturated contrast-enhanced three-dimensional MR angiography compared with non-fat-saturated and conventional fat-saturated MR angiography. , 2000, Radiology.

[31]  Klaus Scheffler,et al.  Time‐resolved projection angiography after bolus injection of contrast agent , 1997, Magnetic resonance in medicine.

[32]  M. Prince Gadolinium-enhanced MR aortography. , 1990, Radiology.

[33]  U Salvolini,et al.  Contrast-enhanced MR angiography (CE MRA) in the study of the carotid stenosis: comparison with digital subtraction angiography (DSA). , 1999, Journal of neuroradiology. Journal de neuroradiologie.

[34]  N. Rofsky,et al.  Gadolinium-enhanced 3D MRA of the aortic arch vessels in the detection of atherosclerotic cerebrovascular occlusive disease. , 1998, Journal of computer assisted tomography.

[35]  M Galanski,et al.  Renal arterial stenoses: spiral CT angiography. , 1993, Radiology.

[36]  D. L. Johnston,et al.  Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction , 1996, Magnetic resonance in medicine.