The use of a segmented transducer for rib sparing in HIFU treatments.

The use of focused ultrasound as a minimally invasive treatment for tumours is rapidly expanding. Target organs include the liver and kidneys. Both single element and phased array transducers may be used in the clinic. The presence of the rib cage presents a problem in high intensity focused ultrasound (HIFU) treatment planning, due to its high attenuation of the HIFU beam resulting in a loss of power at the focus as well as an increase in the risk of damage at the rib and to overlying tissues, including the skin. In this paper, a linearly segmented transducer, in which all active elements are driven in phase, has been investigated. The aim of the study was to investigate how a beam with a clinically useful profile could be achieved by removing the contribution of edge segments from one side of the transducer to the field. We have considered the case in which the HIFU beam approaches the rib cage during a treatment and investigated configurations of the transducer for which up to three segments on the edge are switched off. This problem has been studied initially using a linear acoustic field program to model the segmented transducer's acoustic beam profile. Experimental measurements of the transducer's acoustic field were performed using an automated beam plotting system. Temperature measurements were made on a rib surface for two transducer configurations using a fine wire thermocouple. A thermochromic liquid crystal material was used to assess qualitatively the heating pattern generated by the ultrasound beam. We show the rib sparing potential of the segmented transducer during HIFU treatment by demonstrating a reduction in the prefocal width of the ultrasound beam when edge segments are switched off. This has been predicted with the acoustic field model and demonstrated experimentally by acoustic field measurements and observations of the heating pattern generated by the ultrasound beam. A significant decrease in the temperature rise on a rib was observed in the case for which three edge segments were switched off compared with when all segments were active. We conclude that a segmented transducer extends the potential for treating liver tumours. In the case where the tumour lies behind, but close to the edge of, the ribs, energy loss at the focus and excessive heating in the rib and overlying tissue can be avoided by switching off edge segments.

[1]  J R Mallard,et al.  Errors in temperature measurement by thermocouple probes during ultrasound induced hyperthermia. , 1983, The British journal of radiology.

[2]  C R Hill,et al.  Lesion development in focused ultrasound surgery: a general model. , 1994, Ultrasound in medicine & biology.

[3]  W. Fry,et al.  Determination of Absolute Sound Levels and Acoustic Absorption Coefficients by Thermocouple Probes—Theory , 1954 .

[4]  A. Horwich,et al.  Preliminary results of a phase I dose escalation clinical trial using focused ultrasound in the treatment of localised tumours. , 1999, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.

[5]  A Study Of The Acoustic Profile Of A Segmented Clinical Focused Ultrasound Transducer , 2005 .

[6]  Wen-Zhi Chen,et al.  Extracorporeal high intensity focused ultrasound ablation in the treatment of 1038 patients with solid carcinomas in China: an overview. , 2004, Ultrasonics sonochemistry.

[7]  G. Haar,et al.  Temperature Measurement in ex-vivo Bovine Liver using Fine-Wire and Thin-Film Thermocouples , 2006 .

[8]  J. Goodman Introduction to Fourier optics , 1969 .

[9]  Guy Vallancien,et al.  Focused Extracorporeal Pyrotherapy: Feasibility Study in Man , 1992 .

[10]  R. Clarke,et al.  Modification of intensity distributions from large aperture ultrasound sources. , 1995, Ultrasound in medicine & biology.

[11]  F. Gleeson,et al.  High-intensity focused ultrasound for the treatment of liver tumours. , 2004, Ultrasonics.

[12]  Bob Clarke,et al.  A Phased Strip Array HIFU Transducer , 2006 .

[13]  K Hynynen,et al.  In vivo demonstration of noninvasive thermal surgery of the liver and kidney using an ultrasonic phased array. , 1999, Ultrasound in medicine & biology.

[14]  F V Gleeson,et al.  The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population , 2005, British Journal of Cancer.

[15]  Gail R. ter Haar,et al.  Phase one clinical trial of the use of focused ultrasound surgery for the treatment of soft-tissue tumors , 1998, Photonics West - Biomedical Optics.

[16]  J. Volakis,et al.  Optimal synthesis of phased array field patterns in the presence of the ribcage , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[17]  G. Hahn,et al.  Clinical studies with ultrasound-induced hyperthermia. , 1982, National Cancer Institute monograph.