Variable‐angle total internal reflection fluorescence microscopy (VA‐TIRFM): realization and application of a compact illumination device

A novel compact illumination device in variable‐angle total internal reflection fluorescence microscopy (VA‐TIRFM) is described. This device replaces the standard condensor of an upright microscope. Light from different laser sources is delivered via a monomode fibre and focused onto identical parts of a sample under variable angles of total internal reflection. Thus, fluorophores in close proximity to a cell–substrate interface are excited by an evanescent wave with variable penetration depth, and localized with high (nanometre) axial resolution. In addition to quantitative measurements in solution, fluorescence markers of the cytoplasm and the plasma membrane, i.e. calcein and laurdan, were examined using cultivated endothelial cells. Distances between the glass substrate and the plasma membrane were determined using the mathematical algorithm of a four‐layer model, as well as a Gaussian‐shaped intensity profile of the illumination spot on the samples. Distances between 0 and 30 nm in focal contacts and between 100 and 300 nm in other parts of the cell were thus determined. In addition to measurements of cell–substrate topology, the illumination device appears appropriate for numerous applications in which high axial resolution is required, e.g. experiments on endocytosis or exocytosis, as well as measurements of ion concentrations proximal to the plasma membrane. The compact illumination device is also suitable for combining TIRFM with further innovative techniques, e.g. time‐resolved fluorescence spectroscopy, fluorescence lifetime imaging (FLIM) or fluorescence resonance energy transfer (FRET).

[1]  C Bechinger,et al.  Imaging of cell/substrate contacts of living cells with surface plasmon resonance microscopy. , 1999, Biophysical journal.

[2]  N. Thompson,et al.  Effect of planar dielectric interfaces on fluorescence emission and detection. Evanescent excitation with high-aperture collection. , 1984, Biophysical journal.

[3]  W S Strauss,et al.  Time-gated fluorescence microscopy in cellular and molecular biology. , 1998, Cellular and molecular biology.

[4]  O. Heavens,et al.  General electromagnetic theory of total internal reflection fluorescence: the quantitative basis for mapping cell-substratum topography. , 1987, Journal of cell science.

[5]  G. Fuhr,et al.  Cryopreservation of anchorage-dependent mammalian cells fixed to structured glass and silicon substrates. , 1996, Cryobiology.

[6]  G. Truskey,et al.  Total internal reflection fluorescence microscopy (TIRFM). II. Topographical mapping of relative cell/substratum separation distances. , 1992, Journal of cell science.

[7]  G. Truskey,et al.  Quantitative analysis of variable‐angle total internal reflection fluorescence microscopy (VA‐TIRFM) of cell/substrate contacts , 1994, Journal of microscopy.

[8]  ウェッブ、ウォット・ダブリュー,et al.  Two-photon laser scanning microscope , 1990 .

[9]  G. Omann,et al.  Membrane-proximal calcium transients in stimulated neutrophils detected by total internal reflection fluorescence. , 1996, Biophysical journal.

[10]  S. Hell,et al.  4Pi‐confocal images with axial superresolution , 1996 .

[11]  D. Axelrod,et al.  Actin dynamics at the living cell submembrane imaged by total internal reflection fluorescence photobleaching. , 2000, Biophysical journal.

[12]  S. Hell,et al.  Focal spots of size lambda/23 open up far-field fluorescence microscopy at 33 nm axial resolution. , 2002, Physical review letters.

[13]  W S Strauss,et al.  Selective Examination of Plasma Membrane–Associated Photosensitizers Using Total Internal Reflection Fluorescence Spectroscopy: Correlation between Photobleaching and Photodynamic Efficacy of Protoporphyrin IX , 1998, Photochemistry and photobiology.

[14]  J. Lakowicz,et al.  Fluorescence lifetime imaging of nuclear DNA: effect of fluorescence resonance energy transfer. , 2000, Cytometry.

[15]  D. Axelrod,et al.  Evanescent field excitation of fluorescence by epi-illumination microscopy. , 1989, Applied optics.

[16]  Brian Herman,et al.  Bcl-2 and Bax interactions in mitochondria probed with green fluorescent protein and fluorescence resonance energy transfer , 1998, Nature Biotechnology.

[17]  Martin Oheim,et al.  Multiple stimulation-dependent processes regulate the size of the releasable pool of vesicles , 1999, European Biophysics Journal.

[18]  G. Truskey,et al.  Total internal reflection fluorescence (TIRF) microscopy. I. Modelling cell contact region fluorescence. , 1990, Journal of cell science.

[19]  W. Denk,et al.  Two-photon laser scanning fluorescence microscopy. , 1990, Science.

[20]  A. Rohrbach,et al.  Observing secretory granules with a multiangle evanescent wave microscope. , 2000, Biophysical journal.

[21]  R. Steiner,et al.  Plasma Membrane Associated Location of Sulfonated meso-Tetraphenyl-porphyrins of Different Hydrophilicity Probed by Total Internal Reflection Fluorescence Spectroscopy , 2000 .

[22]  D. Axelrod,et al.  Fluorescence emission at dielectric and metal-film interfaces , 1987 .

[23]  W. Betz,et al.  Imaging exocytosis and endocytosis , 1996, Current Opinion in Neurobiology.

[24]  M. H. Gschwend,et al.  Time-resolved in situ measurement of mitochondrial malfunction by energy transfer spectroscopy. , 2000, Journal of biomedical optics.

[25]  D. Gingell,et al.  Interference reflection microscopy. A quantitative theory for image interpretation and its application to cell-substratum separation measurement. , 1979, Biophysical journal.

[26]  R. Iino,et al.  Single-Fluorophore Dynamic Imaging in Living Cells , 2001, Journal of Fluorescence.

[27]  Y. K. Levine,et al.  Quantitative pH imaging in cells using confocal fluorescence lifetime imaging microscopy. , 1995, Analytical biochemistry.

[28]  Toshio Yanagida,et al.  Single-molecule imaging of EGFR signalling on the surface of living cells , 2000, Nature Cell Biology.

[29]  B. Ölveczky,et al.  Mapping fluorophore distributions in three dimensions by quantitative multiple angle-total internal reflection fluorescence microscopy. , 1997, Biophysical journal.

[30]  D. Axelrod Cell-substrate contacts illuminated by total internal reflection fluorescence , 1981, The Journal of cell biology.

[31]  N. Thompson,et al.  Equilibrium, Kinetics, Diffusion and Self‐Association of Proteins at Membrane Surfaces: Measurement by Total Internal Reflection Fluorescence Microscopy , 1997, Photochemistry and photobiology.

[32]  P. Fromherz,et al.  No correlation of focal contacts and close adhesion by comparing GFP-vinculin and fluorescence interference of DiI , 2001, European Biophysics Journal.

[33]  D. Loerke,et al.  The last few milliseconds in the life of a secretory granule , 1998, European Biophysics Journal.

[34]  H Szmacinski,et al.  Fluorescence lifetime imaging microscopy: homodyne technique using high-speed gated image intensifier. , 1994, Methods in enzymology.

[35]  K. König,et al.  Multiphoton microscopy in life sciences , 2000, Journal of microscopy.

[36]  E Gratton,et al.  Phase fluctuation in phospholipid membranes revealed by Laurdan fluorescence. , 1990, Biophysical journal.

[37]  P. Bastiaens,et al.  Fluorescence lifetime imaging microscopy: spatial resolution of biochemical processes in the cell. , 1999, Trends in cell biology.

[38]  C. S. Izzard,et al.  Cell-to-substrate contacts in living fibroblasts: an interference reflexion study with an evaluation of the technique. , 1976, Journal of cell science.

[39]  Fred S. Wouters,et al.  Imaging FRET between spectrally similar GFP molecules in single cells , 2001, Nature Biotechnology.