The Validity of a New Noncontact Tonometer and Its Comparison with the Goldmann Tonometer

Purpose. This study compared a new noncontact tonometer (NCT), the Nidek NT-4000 (Nidek Co., Ltd., Aichi, Japan), with a pulse detection feature; an earlier model, the Nidek NT-2000, without this pulse detection facility; and Goldmann tonometry. Methods. Thirty-one young subjects had their intraocular pressure (IOP) in one eye randomly measured by two NCT’s, followed by a Goldmann tonometer. The pulse detection mode used by the NT-4000 included synchronizing the IOP with the peak of the pulse (P-P), the middle of the pulse (P-M), or the bottom of the pulse (P-B). The order of measurements from these three modes was also random. Three consecutive readings were obtained from each mode/tonometer, and the mean was used for analysis. Results. Goldmann tonometry demonstrated the smallest variation from consecutive measurements (coefficient of variation, <4%), followed by the NT-4000 (coefficient of variation, <5% in various modes) and the NT-2000 (coefficient of variation, >5%). For the NT-4000, the mean IOP decreased from the highest in the P-P mode (16.1 mm Hg) to the lowest in the P-B mode (14.7 mm Hg), with the P-M mode in the middle. A significant difference was found among the IOP readings using the NT-4000 (in various modes), NT-2000, and Goldmann tonometry (repeated-measures analysis of variance, p < 0.01). More than 80% of the results from the NT-4000 were within 3 mm Hg of those from the Goldmann tonometry. Conclusions. The pulse detection feature from this new NCT could capture and monitor pulse waves, thus reducing the variations in the consecutive measurements. The NT-4000 also performed better than the NT-2000 when compared with the Goldmann tonometry.

[1]  P Schilder,et al.  Estimation of pulsatile ocular blood flow from intraocular pressure , 1989, Acta ophthalmologica. Supplement.

[2]  H. Quigley Number of people with glaucoma worldwide. , 1996, The British journal of ophthalmology.

[3]  G. E. McCaghrey,et al.  The Pulsair 3000 tonometer — how many readings need to be taken to ensure accuracy of the average? , 2001, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[4]  G N Dutton,et al.  Causes of blindness and visual impairment in the West of Scotland , 2004, Eye.

[5]  M. Whitacre,et al.  Sources of error with use of Goldmann-type tonometers. , 1993, Survey of ophthalmology.

[6]  N. Nicastro Intraocular pressure--the cardiac connection. , 1991, Annals of ophthalmology.

[7]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[8]  R. Moses Repeated applanation tonometry. , 1961, Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde.

[9]  G. Johnson,et al.  The Burden of Trachoma in the Rural Nile Delta of Egypt : a Survey of Menofiya Governorate The Epidemiology of Ocular Trauma in Singapore : Perspective from the Emergency Service of a Large Tertiary Hospital , 2005 .

[10]  J. Jay,et al.  Clinical comparison of the Keeler Pulsair 2000, American Optical MkII and Goldmann applanation tonometers , 1996, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[11]  K. Myers REPEATABILITY OF IOP MEASUREMENT WITH THE NON‐CONTACT TONOMETER* , 1974 .

[12]  B. Prum,et al.  The advanced glaucoma intervention study (AGIS): 7. the relationship between control of intraocular pressure and visual field deterioration , 2000 .

[13]  R. P. Mills,et al.  Interim clinical outcomes in the Collaborative Initial Glaucoma Treatment Study comparing initial treatment randomized to medications or surgery. , 2001, Ophthalmology.

[14]  L. Gnanaraj,et al.  Clinical Comparison of Ocular Blood Flow Tonometer, Tonopen, and Goldmann Applanation Tonometer for Measuring Intraocular Pressure in Postkeratoplasty Eyes , 2001, Cornea.

[15]  Y. Shih,et al.  Ocular pulse amplitude in myopia. , 1991, Journal of ocular pharmacology.

[16]  H. Chan,et al.  A preliminary study on the Ocular Blood Flow (OBF) of Hong Kong Chinese , 1999, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[17]  A. Lam,et al.  The Effect of Myopic Axial Elongation and Posture on the Pulsatile Ocular Blood Flow in Young Normal Subjects , 2002, Optometry and vision science : official publication of the American Academy of Optometry.

[18]  P. Cho,et al.  Comparison of the Performance of the Nidek NT-2000 Noncontact Tonometer with the Keeler Pulsair 2000 and the Goldmann Applanation Tonometer , 1997, Optometry and vision science : official publication of the American Academy of Optometry.

[19]  M. Batterbury,et al.  Intraocular pressure and pulse rate measurements by the OBF tonograph — comparison to reference instruments , 2000, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[20]  A. Paranhos,et al.  Influence of Keratometric Readings on Comparative Intraocular Pressure Measurements With Goldmann, Tono‐Pen, and Noncontact Tonometers , 2000, Journal of glaucoma.

[21]  R. Klein,et al.  Causes and prevalence of visual impairment among adults in the United States. , 2004, Archives of ophthalmology.

[22]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[23]  Suk-tak Chan,et al.  The effect of axial length on ocular blood flow assessment in anisometropes , 2003, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.