An Electrochemical Immunobiosensor for Direct Detection of Veterinary Drug Residues in Undiluted Complex Matrices

An electrochemical immunobiosensor is developed that allows the detection of small molecules, such as drugs, in undiluted complex samples, with no washing or rinsing steps via a displacement assay. This is achieved using an interface comprised of a mixed layer of oligo(phenylethynylene) molecular wire (MW), to allow electrochemical communication, and oligo(ethylene glycol) (OEG) to control the interaction of proteins and electroactive interferences with the electrode surface. The mixed layer is formed from in situ-generated aryl diazonium cations. To the distal end of the MW, a redox probe 1,1’-di(aminomethyl)ferrocene (FDMA) is attached followed by an epitope (the structural feature the antibody selectively recognizes) to which an antibody would bind. Association or dissociation of the antibody with the sensing interface causes a modulation of the ferrocene electrochemistry. Antibody complexed electrodes are exposed to samples containing spiked enrofloxacin (unbound target analyte), in milk and environmental water and interrogated using square wave voltammetry (SWV). The lowest detected concentration of free enrofloxacin was 10 pg mL 1 in phosphate buffer, 50 mM, pH 7. For free enrofloxacin detection in undiluted complex matrices, by adding disodium EDTA (50 mM), the recovery obtained was 94.1 % in skim milk and 88.5 % in stream water, respectively as compared to clean phosphate buffer. The immunobiosensor response time was 10– 15 minutes. The sensor performance in milk was shown to be superior to a standard method based on Liquid Chromatography Mass Spectroscopy (LC-MS/MS).

[1]  G. Palleschi,et al.  Rapid antibody biosensor assays for environmental analysis. , 2000, Biochemical Society transactions.

[2]  H. Hakusui,et al.  Interaction of quinolones with metal cations in aqueous solution , 1996 .

[3]  L. Okerman,et al.  Simultaneous determination of different antibiotic residues in bovine and in porcine kidneys by solid-phase fluorescence immunoassay. , 2003, Journal of AOAC International.

[4]  A. Asanov,et al.  Regenerable biosensor platform: a total internal reflection fluorescence cell with electrochemical control. , 1998, Analytical chemistry.

[5]  B. Urbaniak,et al.  Analysis of the factors that significantly influence the stability of fluoroquinolone-metal complexes. , 2009, Analytica chimica acta.

[6]  S. Kır,et al.  Improved determination of quinolones in milk at their MRL levels using LC-UV, LC-FD, LC-MS and LC-MS/MS and validation in line with regulation 2002/657/EC. , 2008, Analytica chimica acta.

[7]  J. Shim,et al.  Determination of the fluoroquinolone enrofloxacin in edible chicken muscle by supercritical fluid extraction and liquid chromatography with fluorescence detection. , 2003, Journal of agricultural and food chemistry.

[8]  R. Smalley,et al.  Functionalization of carbon nanotubes by electrochemical reduction of aryl diazonium salts: a bucky paper electrode. , 2001, Journal of the American Chemical Society.

[9]  M. Papich,et al.  Simultaneous determination of enrofloxacin and its primary metabolite ciprofloxacin in bovine milk and plasma by ion-pairing liquid chromatography. , 1994, Journal of chromatography. B, Biomedical applications.

[10]  R. Draisci,et al.  Determination of enrofloxacin and its metabolite ciprofloxacin in goat milk by high-performance liquid chromatography with diode-array detection. Optimization and validation. , 2003, Journal of chromatography. A.

[11]  P. A. Vigato,et al.  Synthesis, structure and properties of new ferrocene-containing compounds , 2003 .

[12]  S. Upadhyay,et al.  Complexes of quinolone drugs norfloxacin and ciprofloxacin with alkaline earth metal perchlorates , 2006 .

[13]  G. Whitesides,et al.  Self-assembled organic monolayers: model systems for studying adsorption of proteins at surfaces , 1991, Science.

[14]  M. Marco,et al.  Electrochemical magneto immunosensing of antibiotic residues in milk. , 2007, Biosensors & bioelectronics.

[15]  M. Paddon-Row,et al.  Protein modulation of electrochemical signals: application to immunobiosensing. , 2008, Chemical communications.

[16]  Ching-Chou Wu,et al.  Development of an enrofloxacin immunosensor based on label-free electrochemical impedance spectroscopy. , 2009, Talanta.

[17]  M. Reed,et al.  Synthesis and preliminary testing of molecular wires and devices. , 2001, Chemistry.

[18]  A. Tsuji,et al.  Monoclonal-based enzyme-linked immunosorbent assay and immunochromatographic assay for enrofloxacin in biological matrices. , 2002, The Analyst.

[19]  G. Sposito,et al.  Binding of ciprofloxacin by humic substances: A molecular dynamics study , 2010, Environmental toxicology and chemistry.

[20]  Sook Mei Khor,et al.  The importance of interfacial design for the sensitivity of a label-free electrochemical immuno-biosensor for small organic molecules. , 2011, Biosensors & bioelectronics.

[21]  S. Nagao,et al.  Characteristics of humic substances in the Kuji River waters as determined by high-performance size exclusion chromatography with fluorescence detection. , 2003, Water research.

[22]  V. Hormazábal,et al.  Rapid Assay for Monitoring Residues of Enrofloxacin in Milk and Meat Tissues by HPLC , 1994 .

[23]  V. Andreu,et al.  Analytical method for simultaneous determination of pesticide and veterinary drug residues in milk by CE‐MS , 2009, Electrophoresis.

[24]  C. Burvenich,et al.  Effect of enrofloxacin treatment on plasma endotoxin during bovine Escherichia coli mastitis , 2002, Inflammation Research.

[25]  T. Gibson,et al.  Use of humic acid solution to remove organic contaminants from hydrogeologic systems. , 1990 .

[26]  P. G. Mccormick Titration of calcium and magnesium in milk with EDTA. , 1973, Journal of chemical education.

[27]  A L Ghindilis,et al.  Immunoassays based on electrochemical detection using microelectrode arrays. , 2004, Biosensors & bioelectronics.

[28]  G. Whitesides,et al.  Adsorption of proteins onto surfaces containing end-attached oligo(ethylene oxide): a model system using self-assembled monolayers , 1993 .

[29]  J. Gooding,et al.  An interface comprising molecular wires and poly(ethylene glycol) spacer units self-assembled on carbon electrodes for studies of protein electrochemistry. , 2006, Langmuir : the ACS journal of surfaces and colloids.

[30]  S. Eremin,et al.  Determination of pesticides by enzyme immunoassay , 2005 .

[31]  M. J. Gracia,et al.  Influence of hard water on the bioavailability of enrofloxacin in broilers. , 2004, Poultry science.

[32]  Shuo Wang,et al.  Sensors and Biosensors for the Determination of Small Molecule Biological Toxins , 2008, Sensors.