Effect of alignment changes on sagittal and coronal socket reaction moment interactions in transtibial prostheses.

Alignment is important for comfortable and stable gait of lower-limb prosthesis users. The magnitude of socket reaction moments in the multiple planes acting simultaneously upon the residual limb may be related to perception of comfort in individuals using prostheses through socket interface pressures. The aim of this study was to investigate the effect of prosthetic alignment changes on sagittal and coronal socket reaction moment interactions (moment-moment curves) and to characterize the curves in 11 individuals with transtibial amputation using novel moment-moment interaction parameters measured by plotting sagittal socket reaction moments versus coronal ones under various alignment conditions. A custom instrumented prosthesis alignment component was used to measure socket reaction moments during walking. Prosthetic alignment was tuned to a nominally aligned condition by a prosthetist, and from this position, angular (3° and 6° of flexion, extension, abduction or adduction of the socket) and translational (5mm and 10mm of anterior, posterior, medial or lateral translation of the socket) alignment changes were performed in either the sagittal or the coronal plane in a randomized manner. A total of 17 alignment conditions were tested. Coronal angulation and translation alignment changes demonstrated similar consistent changes in the moment-moment curves. Sagittal alignment changes demonstrated more complex changes compared to the coronal alignment changes. Effect of sagittal angulations and translations on the moment-moment curves was different during 2nd rocker (mid-stance) with extension malalignment appearing to cause medio-lateral instability. Presentation of coronal and sagittal socket reaction moment interactions may provide useful visual information for prosthetists to understand the biomechanical effects of malalignment of transtibial prostheses.

[1]  John Sullivan,et al.  Monitoring of the load regime applied on the osseointegrated fixation of a trans-femoral amputee: A tool for evidence-based practice , 2008, Prosthetics and orthotics international.

[2]  Laurent Frossard,et al.  Functional Outcome of Transfemoral Amputees Fitted With an Osseointegrated Fixation: Temporal Gait Characteristics , 2010 .

[3]  Edward S. Neumann,et al.  Regression Estimates of Pressure on Transtibial Residual Limbs Using Load Cell Measurements of the Forces and Moments Occurring at the Base of the Socket , 2013 .

[4]  D A Winter,et al.  Performance assessment of the Terry Fox jogging prosthesis for above-knee amputees. , 1989, Journal of biomechanics.

[5]  Ming Zhang,et al.  Perception of socket alignment perturbations in amputees with transtibial prostheses. , 2012, Journal of rehabilitation research and development.

[6]  B. Modan,et al.  Increased cardiovascular disease mortality rates in traumatic lower limb amputees. , 1998, The American journal of cardiology.

[7]  Ming Zhang,et al.  Effect of transtibial prosthesis alignment changes on out-of-plane socket reaction moments during walking in amputees. , 2012, Journal of biomechanics.

[8]  Michael S Orendurff,et al.  Triceps surae force, length and velocity during walking. , 2005, Gait & posture.

[9]  J E Sanders,et al.  A small and lightweight three-channel signal-conditioning unit for strain-gage transducers: a technical note. , 1995, Journal of rehabilitation research and development.

[10]  Edward S. Neumann,et al.  Use of a Load Cell and Force-Moment Analysis to Examine Transtibial Prosthesis Foot Rollover Kinetics for Anterior-Posterior Alignment Perturbations , 2012 .

[11]  Nerrolyn Ramstrand,et al.  Incidence of Lower-Limb Amputation in the Diabetic and Nondiabetic General Population , 2009, Diabetes Care.

[12]  Martin Twiste,et al.  Transverse rotation and longitudinal translation during prosthetic gait--a literature review. , 2003, Journal of rehabilitation research and development.

[13]  David Alan Boone Investigation of socket reactions from transtibial prosthesis malalignment , 2005 .

[14]  Laurent Frossard,et al.  Dynamic input to determine hip joint moments, power and work on the prosthetic limb of transfemoral amputees: ground reaction vs knee reaction , 2011, Prosthetics and orthotics international.

[15]  Kerstin Hagberg,et al.  Kinetics of transfemoral amputees with osseointegrated fixation performing common activities of daily living. , 2007, Clinical biomechanics.

[16]  Laurent A. Frossard,et al.  Load-Relief of Walking Aids on Osseointegrated Fixation: Instrument for Evidence-Based Practice , 2009, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[17]  Kartheek Yalamanchili,et al.  Transducer-based comparisons of the prosthetic feet used by transtibial amputees for different walking activities: a pilot study , 2012, Prosthetics and orthotics international.

[18]  Laurent Frossard,et al.  Apparatus for monitoring load bearing rehabilitation exercises of a transfemoral amputee fitted with an osseointegrated fixation: a proof-of-concept study. , 2010, Gait & posture.

[19]  M. Orendurff,et al.  Influence of malalignment on socket reaction moments during gait in amputees with transtibial prostheses. , 2013, Gait & posture.

[20]  John H. Evans,et al.  Development and preliminary testing of a device for the direct measurement of forces and moments in the prosthetic limb of transfemoral amputees during activities of daily living , 2003 .

[21]  Steven Gray,et al.  Magnitude and variability of loading on the osseointegrated implant of transfemoral amputees during walking. , 2008, Medical engineering & physics.

[22]  J G Buckley,et al.  Chronic low back pain in traumatic lower limb amputees , 2005, Clinical rehabilitation.

[23]  S G Zachariah,et al.  A modular six-directional force sensor for prosthetic assessment: a technical note. , 1997, Journal of rehabilitation research and development.

[24]  R Dumas,et al.  Loading applied on prosthetic knee of transfemoral amputee: comparison of inverse dynamics and direct measurements. , 2009, Gait & posture.

[25]  J. P. Paul,et al.  Alignment of lower-limb prostheses. , 1986, Journal of rehabilitation research and development.

[26]  Paul Stephenson,et al.  Estimation of forces at the interface between an artificial limb and an implant directly fixed into the femur in above-knee amputees , 2002, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[27]  J. Czerniecki,et al.  The prevalence of knee pain and symptomatic knee osteoarthritis among veteran traumatic amputees and nonamputees. , 2005, Archives of physical medicine and rehabilitation.

[28]  A. Patwardhan,et al.  The effect of prosthetic alignment on relative limb loading in persons with trans-tibial amputation: a preliminary report. , 1995, Journal of rehabilitation research and development.

[29]  Helga Wild,et al.  Lower-limb amputee needs assessment using multistakeholder focus-group approach. , 2009, Journal of rehabilitation research and development.