Effect of Low-Temperature Preservation in Optisol-GS on Preloaded, Endothelium-Out DMEK Grafts

The aim of the study was to assess different temperature ranges for the preservation of pre-loaded Descemet Membrane Endothelial Keratoplasty (DMEK) grafts in the DMEK RAPID Mini device. Methods: Three groups of 15 DMEK grafts (five per group) were pre-loaded in the DMEK RAPID Mini and preserved in Optisol-GS for 72 h at different temperatures: group A at >8 °C, group B between 2–8 °C and group C at <2 °C. After stripping and preservation, the viability of the endothelium, cell loss and morphology were assessed through light microscopy following trypan blue and alizarin red staining. Results: Overall mortality was 4.07%, 3.97% and 7.66%, in groups A, B and C, respectively, with percentages of uncovered areas of 0.31%, 1.36% and 0.20% (all p > 0.05). Endothelial cell density variation was 5.51%, 3.06% and 2.82% in groups A, B and C, respectively (p = 0.19). Total Endothelial Cell Loss (ECL) was 4.37%, 5.32% and 7.84% in groups A, B and C, respectively (p = 0.39). Endothelial cell morphology was comparable in all three groups. Conclusions: In the DMEK RAPID Mini, low temperatures (<2 °C) may affect the quality of pre-loaded grafts, inducing a higher ECL after 72 h of preservation, although no significant differences among groups could be proved. Our data would suggest maintaining grafts loaded in the DMEK RAPID Mini at temperatures between 2–8 °C for appropriate preservation.

[1]  S. Ferrari,et al.  Delivering Endothelial Keratoplasty Grafts: Modern Day Transplant Devices , 2022, Current eye research.

[2]  S. Ferrari,et al.  Cost analysis of eye bank versus surgeon prepared endothelial grafts , 2021, BMC Health Services Research.

[3]  Ruth Quilendrino,et al.  Effect of Six-Month Postoperative Endothelial Cell Density on Graft Survival after Descemet Membrane Endothelial Keratoplasty. , 2021, Ophthalmology.

[4]  Youssef W. Naguib,et al.  Solubilized ubiquinol for preserving corneal function. , 2021, Biomaterials.

[5]  R. Fogla,et al.  A Novel Technique for Donor Insertion and Unfolding in Descemet Membrane Endothelial Keratoplasty. , 2021, Cornea.

[6]  S. Ferrari,et al.  Preloaded Descemet Membrane Endothelial Keratoplasty Grafts With Endothelium Outward: A Cross-Country Validation Study of the DMEK Rapid Device. , 2020, Cornea.

[7]  S. Ferrari,et al.  Synthetic media for preservation of corneal tissues deemed for endothelial keratoplasty and endothelial cell culture , 2020, Acta ophthalmologica.

[8]  M. Busin,et al.  Three-Year Outcomes of Tri-Folded Endothelium-In Descemet Membrane Endothelium Keratoplasty with Pull-Through Technique. , 2020, American journal of ophthalmology.

[9]  B. Roald,et al.  Optisol-GS Storage of Cultured Human Limbal Epithelial Cells at Ambient Temperature Is Superior to Hypothermic Storage , 2020, Current eye research.

[10]  P. Català,et al.  Transport and Preservation Comparison of Preloaded and Prestripped-Only DMEK Grafts. , 2020, Cornea.

[11]  M. Farid,et al.  Comparing the effect of three Descemet membrane endothelial keratoplasty injectors on endothelial damage of grafts , 2020, Indian journal of ophthalmology.

[12]  S. Ferrari,et al.  The Influence of Speed During Stripping in Descemet Membrane Endothelial Keratoplasty Tissue Preparation. , 2020, Cornea.

[13]  J. Mehta,et al.  Optimisation of Storage and Transportation Conditions of Cultured Corneal Endothelial Cells for Cell Replacement Therapy , 2020, Scientific Reports.

[14]  M. Banitt,et al.  Quantitative and Qualitative Differences in Endothelial Cell Loss Between Endothelium-In Versus Endothelium-Out Loading in Descemet Membrane Endothelial Keratoplasty. , 2020, Cornea.

[15]  J. Mehta,et al.  Effects of corneal preservation conditions on human corneal endothelial cell culture , 2019, Experimental eye research.

[16]  H. Dua,et al.  Elastin Content and Distribution in Endothelial Keratoplasty Tissue Determines Direction of Scrolling. , 2018, American journal of ophthalmology.

[17]  S. Ferrari,et al.  A comparative study on different Descemet membrane endothelial keratoplasty graft preparation techniques , 2018, Acta ophthalmologica.

[18]  Christopher G. Stoeger,et al.  Cumulative Endothelial Cell Loss in Descemet Membrane Endothelial Keratoplasty Grafts From Preparation Through Insertion With Glass Injectors , 2018, Cornea.

[19]  S. Ferrari,et al.  Descemet Membrane Endothelial Keratoplasty Learning Curve for Graft Preparation in an Eye Bank Using 645 Donor Corneas , 2018, Cornea.

[20]  F. Price,et al.  Endothelium-in Versus Endothelium-out Insertion With Descemet Membrane Endothelial Keratoplasty , 2018, Cornea.

[21]  S. Ferrari,et al.  Comparison of preservation and transportation protocols for preloaded Descemet membrane endothelial keratoplasty , 2017, British Journal of Ophthalmology.

[22]  E. Tu,et al.  Association Between Fungal Contamination and Eye Bank–Prepared Endothelial Keratoplasty Tissue: Temperature-Dependent Risk Factors and Antifungal Supplementation of Optisol–Gentamicin and Streptomycin , 2017, JAMA ophthalmology.

[23]  C. Willoughby,et al.  Mitochondrial dysfunction and oxidative stress in corneal disease. , 2017, Mitochondrion.

[24]  A. Ruzza,et al.  Pull-through technique for delivery of a larger diameter DMEK graft using endothelium-in method. , 2017, Canadian journal of ophthalmology. Journal canadien d'ophtalmologie.

[25]  S. Ferrari,et al.  Endothelium‐in versus endothelium‐out for Descemet membrane endothelial keratoplasty graft preparation and implantation , 2017, Acta ophthalmologica.

[26]  S. Ferrari,et al.  Preservation of Preloaded DMEK Lenticules in Dextran and Non-Dextran-Based Organ Culture Medium , 2016, Journal of ophthalmology.

[27]  O. Damour,et al.  Validation of an endothelial roll preparation for Descemet Membrane Endothelial Keratoplasty by a cornea bank using “no touch” dissection technique , 2016, Cell and Tissue Banking.

[28]  Christopher G. Stoeger,et al.  Quantification and Patterns of Endothelial Cell Loss Due to Eye Bank Preparation and Injector Method in Descemet Membrane Endothelial Keratoplasty Tissues , 2016, Cornea.

[29]  Christopher G. Stoeger,et al.  Imaging and Quantification of Endothelial Cell Loss in Eye Bank Prepared DMEK Grafts Using Trainable Segmentation Software , 2014, Current eye research.

[30]  S. Ferrari,et al.  Descemet membrane endothelial keratoplasty tissue preparation from donor corneas using a standardized submerged hydro-separation method. , 2014, American journal of ophthalmology.

[31]  S. Ferrari,et al.  A quantitative method to evaluate the donor corneal tissue quality used in a comparative study between two hypothermic preservation media , 2014, Cell and Tissue Banking.

[32]  Zhiguo He,et al.  Novel technique for the preparation of corneal grafts for descemet membrane endothelial keratoplasty. , 2013, American journal of ophthalmology.

[33]  D. Ponzin,et al.  Pneumatic dissection and storage of donor endothelial tissue for Descemet's membrane endothelial keratoplasty: a novel technique. , 2010, Ophthalmology.

[34]  J. Nejepínská,et al.  Organ culture, but not hypothermic storage, facilitates the repair of the corneal endothelium following mechanical damage , 2009, Acta ophthalmologica.

[35]  John Calvin Reed,et al.  Effects of organ culture and Optisol-GS storage on structural integrity, phenotypes, and apoptosis in cultured corneal epithelium. , 2007, Investigative ophthalmology & visual science.

[36]  M. Reim,et al.  [Energy metabolism of the human cornea in various culture systems]. , 1997, Klinische Monatsblätter für Augenheilkunde.

[37]  T. Wood,et al.  Freeze-fracture label of functional and dysfunctional human corneal endothelium. , 1987, Current eye research.

[38]  D. Doughman,et al.  Human corneal endothelial layer repair during organ culture. , 1976, Archives of ophthalmology.