Indoor health: background levels of fungi.

There is no uniformity in the suggested guidelines for acceptable levels of fungi in indoor ambient air. Thus, health professionals have no way to determine what levels of fungi may pose a threat to human health. The authors reviewed the published literature to identify data reported for noncomplaint structures, that is, structures in which occupants did not have health concerns associated with the quality of the indoor air. For both commercial and residential structures, fungal concentrations detected were often higher than currently suggested guidance values. The average indoor air concentration in 149 noncomplaint commercial buildings was 233 colony forming units (CFU) per cubic meter, whereas outdoor ambient air levels averaged 983 CFU/m(3). Total indoor spore counts ranged from 610 to 1040 spores/m(3) in three commercial buildings. Outdoor total spore counts associated with these buildings ranged from 400 to 80,000 spores/m(3). The average indoor concentration reported for 820 noncomplaint residential structures was 1252 CFU/m(3) with an average outdoor level of 1524 CFU/m(3). Total spore counts detected indoors at 85 residential structures ranged from 68 to 2307 spores/m(3). Outdoor spore levels associated with these structures ranged from 400 to 80,000 spores/m(3). A large proportion of both commercial and residential noncomplaint structures have indoor ambient air fungal concentrations above 500 CFU/m(3), a level often advocated as requiring remediation in structures when occupants complain of nonspecific adverse health symptoms.

[1]  Y. Cormier,et al.  Assessment of particulates and bioaerosols in eastern Canadian sawmills. , 2000, AIHAJ : a journal for the science of occupational and environmental health and safety.

[2]  W Pei-Chih,et al.  Characteristics of indoor and outdoor airborne fungi at suburban and urban homes in two seasons. , 2000, The Science of the total environment.

[3]  K. Klánová The concentrations of mixed populations of fungi in indoor air: rooms with and without mould problems; rooms with and without health complaints. , 2000, Central European journal of public health.

[4]  B. Leaderer,et al.  Comparisons of seasonal fungal prevalence in indoor and outdoor air and in house dusts of dwellings in one Northeast American county1 , 1999, Journal of Exposure Analysis and Environmental Epidemiology.

[5]  J. D. Cooley,et al.  Correlation between the prevalence of certain fungi and sick building syndrome. , 1998, Occupational and environmental medicine.

[6]  D. Sterling,et al.  Pollen and fungal spores indoor and outdoor of mobile homes. , 1998, Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology.

[7]  C. Hsu,et al.  Indoor pollution and sick building syndrome symptoms among workers in day-care centers. , 1997, Archives of environmental health.

[8]  Karin Foarde,et al.  Cleaning for Improved Indoor Air Quality: an Initial Assessment of Effectiveness , 1997 .

[9]  John C. S. Chang,et al.  Review of quantitative standards and guidelines for fungi in indoor air. , 1996, Journal of the Air & Waste Management Association.

[10]  S. Abbott,et al.  Assessment of worker exposure to airborne molds in honeybee overwintering facilities. , 1996, American Industrial Hygiene Association journal.

[11]  G. D'Amato,et al.  * Aerobiologic and clinical aspects of mould allergy in Europe , 1995, Allergy.

[12]  P. Thorne,et al.  Bioaerosol Concentrations in Noncomplaint, Complaint, and Intervention Homes in the Midwest , 1995 .

[13]  B. Kendrick,et al.  A year-round comparison of fungal spores in indoor and outdoor air , 1995 .

[14]  Y. Kuo,et al.  Characteristics of airborne microfungi in subtropical homes. , 1994, The Science of the total environment.

[15]  P. Malmberg,et al.  Exposure to microorganisms associated with allergic alveolitis and febrile reactions to mold dust in farmers. , 1993, Chest.

[16]  E. Faragher,et al.  An investigation of the relationship between microbial and particulate indoor air pollution and the sick building syndrome. , 1992, Respiratory medicine.

[17]  B. Brunekreef,et al.  Presence of viable mould propagules in indoor air in relation to house damp and outdoor air , 1992, Allergy.

[18]  H. Burger Bioaerosols: prevalence and health effects in the indoor environment. , 1990 .

[19]  A. J. Streifel,et al.  ELEVATED AIRBORNE CONCENTRATIONS OF FUNGI IN RESIDENTIAL AND OFFICE ENVIRONMENTS , 1990 .

[20]  R. McGee,et al.  Airborne microbial contaminants in indoor environments. Naturally ventilated and air-conditioned homes. , 1986, Archives of environmental health.

[21]  P. Kozak,et al.  Aeroallergen exposure in the elementary school setting. , 1986, Annals of allergy.

[22]  J. Kalbfleisch,et al.  Effect of central air conditioning and meteorologic factors on indoor spore counts. , 1978, The Journal of allergy and clinical immunology.

[23]  W. Solomon,et al.  Comparative merits of eight popular media in aerometric studies of fungi. , 1977, The Journal of allergy and clinical immunology.

[24]  W. Solomon,et al.  Comparative recoveries of airborne fungus spores by viable and non-viable modes of volumetric collection , 1977, Mycopathologia.

[25]  Harriet A. Burge,et al.  Dynamics of Airborne Fungal Populations in a Large Office Building , 2000, Current Microbiology.

[26]  E Piecková,et al.  Microscopic fungi in dwellings and their health implications in humans. , 1999, Annals of agricultural and environmental medicine : AAEM.

[27]  C. S. Li,et al.  Airborne fungus allergen in association with residential characteristics in atopic and control children in a subtropical region. , 1997, Archives of environmental health.

[28]  K. Hsieh,et al.  Fungus allergens inside and outside the residences of atopic and control children. , 1995, Archives of environmental health.

[29]  A. Verhoeff,et al.  Health implications of fungi in indoor environments - an overview. , 1994 .

[30]  J M Macher,et al.  A two-year study of microbiological indoor air quality in a new apartment. , 1991, Archives of environmental health.

[31]  E. M. McCabe,et al.  Allergenic and toxigenic micro-organisms in houses. , 1991, Society for Applied Bacteriology symposium series.

[32]  M. Morandi,et al.  A characterization of indoor and outdoor microenvironmental concentrations of pollen and spores in two Houston neighborhoods , 1988 .

[33]  B. Flannigan,et al.  Mould in buildings: the air spora of domestic dwellings , 1988 .

[34]  B. Crook,et al.  Fungal and actinomycete spores as pollutants of the workplace and occupational allergens. , 1988, The Annals of occupational hygiene.

[35]  R. S. Tobin,et al.  Species identification of airborne molds and its significance for the detection of indoor pollution. , 1987, JAPCA.

[36]  T. Vo‐Dinh,et al.  Case Study: Multipollutant Indoor Air Quality Study of 300 Homes in Kingston/Harriman, Tennessee , 1986 .