Bayesian Regularization Applied to Ultrasound Strain Imaging

Noise artifacts due to signal decorrelation and reverberation are a considerable problem in ultrasound strain imaging. For block-matching methods, information from neighboring matching blocks has been utilized to regularize the estimated displacements. We apply a recursive Bayesian regularization algorithm developed by Hayton et al. [Artif. Intell., vol. 114, pp. 125-156, 1999] to phase-sensitive ultrasound RF signals to improve displacement estimation. The parameter of regularization is reformulated, and its meaning examined in the context of strain imaging. Tissue-mimicking experimental phantoms and RF data incorporating finite-element models for the tissue deformation and frequency-domain ultrasound simulations are used to compute the optimal parameter with respect to nominal strain and algorithmic iterations. The optimal strain regularization parameter was found to be twice the nominal strain and did not vary significantly with algorithmic iterations. The technique demonstrates superior performance over median filtering in noise reduction at strains 5% and higher for all quantitative experiments performed. For example, the strain SNR was 11 dB higher than that obtained using a median filter at 7% strain. It has to be noted that for applied deformations lower than 1%, since signal decorrelation errors are minimal, using this approach may degrade the displacement image.

[1]  Alejandro F. Frangi,et al.  Large Diffeomorphic FFD Registration for Motion and Strain Quantification from 3D-US Sequences , 2009, FIMH.

[2]  C. S. Spalding,et al.  In vivo real-time freehand palpation imaging. , 2003, Ultrasound in medicine & biology.

[3]  Lucilio Cordero-Grande,et al.  UsimagTool : an Interactive Research Tool for Ultrasound Image Processing , 2007 .

[4]  Jing Bai,et al.  A multi-scale algorithm for ultrasonic strain reconstruction under moderate compression , 1999 .

[5]  T. Varghese,et al.  Improvement of elastographic displacement estimation using a two-step cross-correlation method. , 2007, Ultrasound in medicine & biology.

[6]  Olivier Basset,et al.  2-D Locally Regularized Tissue Strain Estimation From Radio-Frequency Ultrasound Images: Theoretical Developments and Results on Experimental Data , 2008, IEEE Transactions on Medical Imaging.

[7]  Michel Bertrand,et al.  Noninvasive vascular elastography: theoretical framework , 2004, IEEE Transactions on Medical Imaging.

[8]  J. Stoitsis,et al.  Analysis and quantification of arterial wall motion from B-mode ultrasound images - comparison of block-matching and optical flow , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[9]  T. Varghese,et al.  A theoretical framework for performance characterization of elastography: the strain filter , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  Stephen M. Smith,et al.  A Non-Rigid Registration Algorithm for Dynamic Breast MR Images , 1999, Artif. Intell..

[11]  J. Alison Noble,et al.  Nonrigid registration of 3-D free-hand ultrasound images of the breast , 2002, IEEE Transactions on Medical Imaging.

[12]  J Ophir,et al.  Phase aberration effects in elastography. , 2001, Ultrasound in medicine & biology.

[13]  Jan Flusser,et al.  Image registration methods: a survey , 2003, Image Vis. Comput..

[14]  Jingfeng Jiang,et al.  A generalized speckle tracking algorithm for ultrasonic strain imaging using dynamic programming. , 2009, Ultrasound in medicine & biology.

[15]  Andrew H. Gee,et al.  A quality-guided displacement tracking algorithm for ultrasonic elasticity imaging , 2009, Medical Image Anal..

[16]  Michael J Ackerman,et al.  Engineering and algorithm design for an image processing Api: a technical report on ITK--the Insight Toolkit. , 2002, Studies in health technology and informatics.

[17]  Richard W Prager,et al.  A hybrid displacement estimation method for ultrasonic elasticity imaging , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  Denis Cousineau,et al.  Confidence intervals in within-subject designs: A simpler solution to Loftus and Masson's method , 2005 .

[19]  Ke Liu,et al.  A 2D strain estimator with numerical optimization method for soft-tissue elastography. , 2009, Ultrasonics.

[20]  Jonathan Ophir,et al.  Breast tumor classification using axial shear strain elastography: a feasibility study , 2008, Physics in medicine and biology.

[21]  J Ophir,et al.  Characterization of elastographic noise using the envelope of echo signals. , 1998, Ultrasound in medicine & biology.

[22]  John W. Clark,et al.  Speckle Tracking in Intracardiac Echocardiography for the Assessment of Myocardial Deformation , 2009, IEEE Transactions on Biomedical Engineering.

[23]  K J Parker,et al.  Multilevel and motion model-based ultrasonic speckle tracking algorithms. , 1998, Ultrasound in medicine & biology.

[24]  M. O’Donnell,et al.  Theoretical analysis and verification of ultrasound displacement and strain imaging , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  T. Varghese,et al.  Direct strain estimation in elastography using spectral cross-correlation. , 2000, Ultrasound in medicine & biology.

[26]  T. Varghese,et al.  Two-dimensional multi-level strain estimation for discontinuous tissue , 2007, Physics in medicine and biology.

[27]  Tomy Varghese,et al.  Axial-shear strain imaging for differentiating benign and malignant breast masses. , 2010, Ultrasound in medicine & biology.

[28]  Frédérique Frouin,et al.  Ultrasound elastography based on multiscale estimations of regularized displacement fields , 2004, IEEE Transactions on Medical Imaging.

[29]  J Ophir,et al.  The nonstationary strain filter in elastography: Part II. Lateral and elevational decorrelation. , 1997, Ultrasound in medicine & biology.

[30]  J Jiang,et al.  A parallelizable real-time motion tracking algorithm with applications to ultrasonic strain imaging , 2007, Physics in medicine and biology.

[31]  D. Hill,et al.  Non-rigid image registration: theory and practice. , 2004, The British journal of radiology.

[32]  村上 司,et al.  甲状腺乳頭癌の elastography 所見 , 2005 .

[33]  J. Ophir,et al.  Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues , 1991, Ultrasonic imaging.

[34]  D. Anderson,et al.  Algorithms for minimization without derivatives , 1974 .

[35]  T Varghese,et al.  Electrode displacement strain imaging of thermally-ablated liver tissue in an in vivo animal model. , 2010, Medical physics.

[36]  Gregory D. Hager,et al.  Ultrasound Elastography: A Dynamic Programming Approach , 2008, IEEE Transactions on Medical Imaging.

[37]  Jonathan Ophir,et al.  irnensional Tissue Motion and Its Effect on Image Noise in Elastography , 1997 .

[38]  Gregory D. Hager,et al.  Real-Time Regularized Ultrasound Elastography , 2011, IEEE Transactions on Medical Imaging.

[39]  Fabrice Morestin,et al.  A method for vector displacement estimation with ultrasound imaging and its application for thyroid nodular disease , 2008, Medical Image Anal..

[40]  Yadong Li,et al.  A frequency domain model for generating B-mode images with array transducers , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.