Simulation of Phase Contrast MRI Measurements from Numerical Flow Data

Phase-contrast magnetic resonance imaging (PC-MRI) is a powerful tool for measuring blood flow and has a wide range of cardiovascular applications. Simulation of PC-MRI from numerical flow data would be useful for addressing the data quality of PC-MRI measurements and to study and understand different artifacts. It would also make it possible to optimize imaging parameters prior to the PC-MRI measurements and to evaluate different methods for measuring wall shear stress.Based on previous studies a PC-MRI simulation tool was developed. An Eulerian-Lagrangian approach was used to solve the problem. Computational fluid dynamics (CFD) data calculated on a fix structured mesh (Eulerian point of view) were used as input. From the CFD data spin particle trajectories were computed. The magnetization of the spin particle is then evaluated as the particle travels along its trajectory (Lagrangian point of view).The simulated PC-MRI data were evaluated by comparison with PC-MRI measurements on an in vitro phantom. Results indicate that the PC-MRI simulation tool functions well. However, further development is required to include some of the artifacts. Decreasing the computation time will make more accurate and powerful simulations possible. Several suggestions for improvements are presented in this report.

[1]  M. Yacoub,et al.  Asymmetric redirection of flow through the heart , 2000, Nature.

[2]  Yu-Chung N. Cheng,et al.  Magnetic Resonance Imaging: Physical Principles and Sequence Design , 1999 .

[3]  D Saloner,et al.  Calculation of the magnetization distribution for fluid flow in curved vessels , 1996, Magnetic resonance in medicine.

[4]  W. Nichols McDonald's Blood Flow in Arteries , 1996 .

[5]  H. Gudbjartsson,et al.  The rician distribution of noisy mri data , 1995, Magnetic resonance in medicine.

[6]  Murat Aksoy,et al.  Time‐resolved 3D quantitative flow MRI of the major intracranial vessels: Initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging , 2007, Magnetic resonance in medicine.

[7]  T. Ebbers,et al.  Particle trace visualization of intracardiac flow using time‐resolved 3D phase contrast MRI , 1999, Magnetic resonance in medicine.

[8]  M. Alley,et al.  Comparison of flow patterns in ascending aortic aneurysms and volunteers using four‐dimensional magnetic resonance velocity mapping , 2007, Journal of magnetic resonance imaging : JMRI.

[9]  D Saloner,et al.  A numerical study of magnetic resonance images of pulsatile flow in a two dimensional carotid bifurcation: a numerical study of MR images. , 1998, Medical engineering & physics.

[10]  Julian F. Scott,et al.  An Introduction to Turbulent Flow , 2000 .

[11]  B. Wranne,et al.  Temporally resolved 3D phase‐contrast imaging , 1996, Magnetic resonance in medicine.

[12]  T. Ebbers,et al.  Quantification of intravoxel velocity standard deviation and turbulence intensity by generalizing phase‐contrast MRI , 2006, Magnetic resonance in medicine.

[13]  G. Glover,et al.  Encoding strategies for three‐direction phase‐contrast MR imaging of flow , 1991, Journal of magnetic resonance imaging : JMRI.

[14]  N J Pelc,et al.  Concomitant gradient terms in phase contrast MR: Analysis and correction , 1998, Magnetic resonance in medicine.

[15]  J. Hennig,et al.  Ascending-descending aortic bypass surgery in aortic arch coarctation: four-dimensional magnetic resonance flow analysis. , 2007, The Journal of thoracic and cardiovascular surgery.

[16]  T. Ebbers,et al.  Assessment of fluctuating velocities in disturbed cardiovascular blood flow: In vivo feasibility of generalized phase‐contrast MRI , 2008, Journal of magnetic resonance imaging : JMRI.

[17]  R L Ehman,et al.  Analysis of systematic and random error in MR volumetric flow measurements , 1993, Magnetic resonance in medicine.

[18]  Einar Heiberg,et al.  Transit of blood flow through the human left ventricle mapped by cardiovascular magnetic resonance. , 2007, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[19]  G. Glover,et al.  Generalized reconstruction of phase contrast MRI: Analysis and correction of the effect of gradient field distortions , 2003, Magnetic resonance in medicine.

[20]  Jan Engvall,et al.  Flow patterns in the aortic root and the aorta studied with time-resolved, 3-dimensional, phase-contrast magnetic resonance imaging: implications for aortic valve-sparing surgery. , 2004, The Journal of thoracic and cardiovascular surgery.

[21]  Joseph P. Hornak,et al.  The Basics of MRI , 2003, WWW 2003.

[22]  A. Shaaban,et al.  Wall shear stress and early atherosclerosis: a review. , 2000, AJR. American journal of roentgenology.

[23]  L. Boxt McDonald's blood flow in arteries , 1991, CardioVascular and Interventional Radiology.

[24]  D. Doorly,et al.  Numerical simulations of phase contrast velocity mapping of complex flows in an anatomically realistic bypass graft geometry. , 2006, Medical physics.

[25]  Sylvie Lorthois,et al.  Numerical Simulation of Magnetic Resonance Angiographies of an Anatomically Realistic Stenotic Carotid Bifurcation , 2005, Annals of Biomedical Engineering.