Debulking From Within: A Robotic Steerable Cannula for Intracerebral Hemorrhage Evacuation
暂无分享,去创建一个
Robert J. Webster | Jessica Burgner-Kahrs | Ray A. Lathrop | Philip J. Swaney | Kyle D. Weaver | R. Webster | J. Burgner-Kahrs | P. J. Swaney | K. Weaver | R. Lathrop | P. Swaney
[1] Ron Kikinis,et al. 3D Slicer , 2012, 2004 2nd IEEE International Symposium on Biomedical Imaging: Nano to Macro (IEEE Cat No. 04EX821).
[2] D. Caleb Rucker,et al. A Geometrically Exact Model for Externally Loaded Concentric-Tube Continuum Robots , 2010, IEEE Transactions on Robotics.
[3] Carmelo Anile,et al. Surgical treatment of primary supratentorial intracerebral hemorrhage in stuporous and comatose patients , 2002, Neurological research.
[4] Pierre E. Dupont,et al. Metal MEMS tools for beating-heart tissue removal , 2012, 2012 IEEE International Conference on Robotics and Automation.
[5] Alfredo Quiñones-Hinojosa,et al. Assessment of Image Guided Accuracy in a Skull Model: Comparison of Frameless Stereotaxy Techniques vs. Frame-Based Localization , 2005, Journal of Neuro-Oncology.
[6] D. Cho,et al. A stainless steel sheath for endoscopic surgery and its application in surgical evacuation of putaminal haemorrhage , 2005, Journal of Clinical Neuroscience.
[7] Robert J. Webster,et al. Minimally-invasive intracerebral hemorrhage removal using an active cannula , 2013, 2013 IEEE International Conference on Robotics and Automation.
[8] Lucas Elijovich,et al. Intracerebral Hemorrhage , 2008, Seminars in neurology.
[9] Jessica Burgner,et al. An Autoclavable Steerable Cannula Manual Deployment Device: Design and Accuracy Analysis. , 2012, Journal of medical devices.
[10] Pierre E. Dupont,et al. Design optimization of concentric tube robots based on task and anatomical constraints , 2011, 2011 IEEE International Conference on Robotics and Automation.
[11] John Muschelli,et al. Minimally invasive evacuation of spontaneous intracerebral hemorrhage using sonothrombolysis. , 2011, Journal of neurosurgery.
[12] Russell H. Taylor,et al. Robot-assisted minimally invasive neurosurgical procedures: first experimental experience , 1997, CVRMed.
[13] Hans-Jakob Steiger,et al. Perfusion CT in Patients With Spontaneous Lobar Intracerebral Hemorrhage: Effect of Surgery on Perihemorrhagic Perfusion , 2012, Stroke.
[14] D. Caleb Rucker,et al. A bimanual teleoperated system for endonasal skull base surgery , 2011, 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems.
[15] Pierre E. Dupont,et al. Design and Control of Concentric-Tube Robots , 2010, IEEE Transactions on Robotics.
[16] Toshio Fukuda,et al. Plenary lectures: Problems in neurosurgery — A rich environment for engineer , 2012 .
[17] T. Dalkılıç,et al. The effects on prognosis of surgical treatment of hypertensive putaminal hematomas through transsylvian transinsular approach. , 2003, Surgical Neurology.
[18] G. Dogangil,et al. A review of medical robotics for minimally invasive soft tissue surgery , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[19] Russell H. Taylor,et al. A Perspective on Medical Robotics , 2006, Proceedings of the IEEE.
[20] Rajiv Gupta,et al. Towards a compact robotically steerable thermal ablation probe , 2012, 2012 IEEE International Conference on Robotics and Automation.
[21] C.N. Riviere,et al. Toward Effective Needle Steering in Brain Tissue , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.
[22] Wei Zhang,et al. Gross-total hematoma removal of hypertensive basal ganglia hemorrhages: A long-term follow-up , 2009, Journal of the Neurological Sciences.
[23] D. Louw,et al. Surgical Robotics: A Review and Neurosurgical Prototype Development , 2004, Neurosurgery.
[24] J. Murthy,et al. Decompressive craniectomy with clot evacuation in large hemispheric hypertensive intracerebral hemorrhage , 2005, Neurocritical care.
[25] Chien-hua Chen,et al. Aspiration of Hypertensive Intracerebral Hematoma with Frameless and Fiducial-Free Navigation System: Technical Note and Preliminary Result , 2008, Stereotactic and Functional Neurosurgery.
[26] Robert J. Webster,et al. Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review , 2010, Int. J. Robotics Res..
[27] Ale Algra,et al. Incidence, case fatality, and functional outcome of intracerebral haemorrhage over time, according to age, sex, and ethnic origin: a systematic review and meta-analysis , 2010, The Lancet Neurology.
[28] Gregory S. Chirikjian,et al. Nonholonomic Modeling of Needle Steering , 2006, Int. J. Robotics Res..
[29] Robert J. Webster,et al. On the computational design of concentric tube robots: Incorporating volume-based objectives , 2013, 2013 IEEE International Conference on Robotics and Automation.
[30] Tomer Anor,et al. Algorithms for design of continuum robots using the concentric tubes approach: A neurosurgical example , 2011, 2011 IEEE International Conference on Robotics and Automation.
[31] S. Hayati,et al. A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgery , 1988, IEEE Transactions on Biomedical Engineering.
[32] N. Venketasubramanian,et al. Hypertensive basal ganglia hemorrhage: a prospective study comparing surgical and nonsurgical management. , 2001, Surgical neurology.
[33] Jeffry Alger,et al. Image-guided endoscopic evacuation of spontaneous intracerebral hemorrhage. , 2008, Surgical neurology.