Design of a neural stimulator system with closed-loop charge cancellation

The safety of electrode-tissue interface under electrical neural stimulation is a critical matter and thus precise control of the electrode voltage needs to be warranted. Analytical study on the electrode potential profile during electrical stimulation justifies the need of using a closed-loop system to regulate the electrode voltage. A neural stimulator with cancellation of excessive charge is proposed. The design procedure and methodology are presented to provide general guidelines for similar system designs. Simulation results demonstrate that neural stimulation safety can be achieved by the proposed design methodology.

[1]  Albrecht Rothermel,et al.  A CMOS Chip With Active Pixel Array and Specific Test Features for Subretinal Implantation , 2009, IEEE Journal of Solid-State Circuits.

[2]  Thomas Stieglitz,et al.  A voltage-controlled current source with regulated electrode bias-voltage for safe neural stimulation , 2008, Journal of Neuroscience Methods.

[3]  Daniel R. Merrill,et al.  Electrical stimulation of excitable tissue: design of efficacious and safe protocols , 2005, Journal of Neuroscience Methods.

[4]  Rahul Sarpeshkar,et al.  A Low-Power Blocking-Capacitor-Free Charge-Balanced Electrode-Stimulator Chip With Less Than 6 nA DC Error for 1-mA Full-Scale Stimulation , 2007, IEEE Transactions on Biomedical Circuits and Systems.

[5]  Blake S. Wilson,et al.  Cochlear implants: A remarkable past and a brilliant future , 2008, Hearing Research.

[6]  Maurits Ortmanns,et al.  An Active Approach for Charge Balancing in Functional Electrical Stimulation , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[7]  Hoi Lee,et al.  Biphasic-current-pulse self-calibration techniques for monopolar current stimulation , 2009, 2009 IEEE Biomedical Circuits and Systems Conference.

[8]  T. Lehmann,et al.  Implantable stimulator for bipolar stimulation without charge balancing circuits , 2010, 2010 Biomedical Circuits and Systems Conference (BioCAS).

[9]  R. Shepherd,et al.  Electrical stimulation of the auditory nerve: direct current measurement in vivo , 1999, IEEE Transactions on Biomedical Engineering.

[10]  Anthony Lam,et al.  A Matching Technique for Biphasic Stimulation Pulse , 2007, 2007 IEEE International Symposium on Circuits and Systems.

[11]  J. Thomas Mortimer,et al.  Imbalanced biphasic electrical stimulation: Muscle tissue damage , 2006, Annals of Biomedical Engineering.

[12]  Andreas Demosthenous,et al.  An Integrated Implantable Stimulator That is Fail-Safe Without Off-Chip Blocking-Capacitors , 2008, IEEE Transactions on Biomedical Circuits and Systems.

[13]  J. McHardy,et al.  An approach to corrosion control during electrical stimulation , 1977, Annals of Biomedical Engineering.