A new method for quantifying the performance of EEG blind source separation algorithms by referencing a simultaneously recorded ECoG signal

Blind source separation (BSS) algorithms extract neural signals from electroencephalography (EEG) data. However, it is difficult to quantify source separation performance because there is no criterion to dissociate neural signals and noise in EEG signals. This study develops a method for evaluating BSS performance. The idea is neural signals in EEG can be estimated by comparison with simultaneously measured electrocorticography (ECoG). Because the ECoG electrodes cover the majority of the lateral cortical surface and should capture most of the original neural sources in the EEG signals. We measured real EEG and ECoG data and developed an algorithm for evaluating BSS performance. First, EEG signals are separated into EEG components using the BSS algorithm. Second, the EEG components are ranked using the correlation coefficients of the ECoG regression and the components are grouped into subsets based on their ranks. Third, canonical correlation analysis estimates how much information is shared between the subsets of the EEG components and the ECoG signals. We used our algorithm to compare the performance of BSS algorithms (PCA, AMUSE, SOBI, JADE, fastICA) via the EEG and ECoG data of anesthetized nonhuman primates. The results (Best case >JADE = fastICA >AMUSE = SOBI ≥ PCA >random separation) were common to the two subjects. To encourage the further development of better BSS algorithms, our EEG and ECoG data are available on our Web site (http://neurotycho.org/) as a common testing platform.

[1]  T. Sejnowski,et al.  Removing electroencephalographic artifacts by blind source separation. , 2000, Psychophysiology.

[2]  L. Zhukov,et al.  Independent component analysis for EEG source localization , 2000, IEEE Engineering in Medicine and Biology Magazine.

[3]  J. Cardoso,et al.  Blind beamforming for non-gaussian signals , 1993 .

[4]  Miguel Angel Mañanas,et al.  A comparative study of automatic techniques for ocular artifact reduction in spontaneous EEG signals based on clinical target variables: A simulation case , 2008, Comput. Biol. Medicine.

[5]  Yasuo Nagasaka,et al.  Multidimensional Recording (MDR) and Data Sharing: An Ecological Open Research and Educational Platform for Neuroscience , 2011, PloS one.

[6]  H Sattel,et al.  Discrimination of Alzheimer's disease and normal aging by EEG data. , 1997, Electroencephalography and clinical neurophysiology.

[7]  Roozbeh Jafari,et al.  Automatic EEG artifact removal based on ICA and Hierarchical Clustering , 2012, 2012 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP).

[8]  Saeid Sanei,et al.  EEG signal processing , 2000, Clinical Neurophysiology.

[9]  Z.J. Koles,et al.  Principal-component localization of the sources of the background EEG , 1995, IEEE Transactions on Biomedical Engineering.

[10]  Soo-Young Lee Blind Source Separation and Independent Component Analysis: A Review , 2005 .

[11]  Robert Oostenveld,et al.  FieldTrip: Open Source Software for Advanced Analysis of MEG, EEG, and Invasive Electrophysiological Data , 2010, Comput. Intell. Neurosci..

[12]  Vera Kaiser,et al.  What does clean EEG look like? , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  P. Comon,et al.  Ica: a potential tool for bci systems , 2008, IEEE Signal Processing Magazine.

[14]  R. Liu,et al.  AMUSE: a new blind identification algorithm , 1990, IEEE International Symposium on Circuits and Systems.

[15]  A. Mognon,et al.  ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features. , 2011, Psychophysiology.

[16]  P. Grant,et al.  Dopaminergic foundations of schizotypy as measured by the German version of the Oxford-Liverpool Inventory of Feelings and Experiences (O-LIFE)—a suitable endophenotype of schizophrenia , 2013, Front. Hum. Neurosci..

[17]  S. Muthukumaraswamy High-frequency brain activity and muscle artifacts in MEG/EEG: a review and recommendations , 2013, Front. Hum. Neurosci..

[18]  Eric Moulines,et al.  A blind source separation technique using second-order statistics , 1997, IEEE Trans. Signal Process..

[19]  T. Sejnowski,et al.  Dynamic Brain Sources of Visual Evoked Responses , 2002, Science.

[20]  Eduardo Martínez-Montes,et al.  EEG source imaging with spatio‐temporal tomographic nonnegative independent component analysis , 2009, Human brain mapping.

[21]  Erkki Oja,et al.  Independent component approach to the analysis of EEG and MEG recordings , 2000, IEEE Transactions on Biomedical Engineering.

[22]  Bart Vanrumste,et al.  Validation of ICA as a tool to remove eye movement artifacts from EEG/ERP. , 2010, Psychophysiology.

[23]  Terrence J. Sejnowski,et al.  Enhanced detection of artifacts in EEG data using higher-order statistics and independent component analysis , 2007, NeuroImage.

[24]  M. Tangermann,et al.  Automatic Classification of Artifactual ICA-Components for Artifact Removal in EEG Signals , 2011, Behavioral and Brain Functions.

[25]  H. Hotelling Relations Between Two Sets of Variates , 1936 .

[26]  Tzyy-Ping Jung,et al.  Independent Component Analysis of Electroencephalographic Data , 1995, NIPS.

[27]  Mercedes Atienza,et al.  Muscle Artifact Removal from Human Sleep EEG by Using Independent Component Analysis , 2008, Annals of Biomedical Engineering.

[28]  Hernando Ombao,et al.  Time-dependent frequency domain principal components analysis of multichannel non-stationary signals , 2006, Comput. Stat. Data Anal..

[29]  Jaime Gómez Gil,et al.  Brain Computer Interfaces, a Review , 2012, Sensors.

[30]  Aapo Hyvärinen,et al.  Fast and robust fixed-point algorithms for independent component analysis , 1999, IEEE Trans. Neural Networks.

[31]  Andreas Schulze-Bonhage,et al.  Signal quality of simultaneously recorded invasive and non-invasive EEG , 2009, NeuroImage.

[32]  Aapo Hyvärinen,et al.  Icasso: software for investigating the reliability of ICA estimates by clustering and visualization , 2003, 2003 IEEE XIII Workshop on Neural Networks for Signal Processing (IEEE Cat. No.03TH8718).

[33]  G Pfurtscheller,et al.  Frequency dependence of the transmission of the EEG from cortex to scalp. , 1975, Electroencephalography and clinical neurophysiology.

[34]  Andrzej Cichocki,et al.  Blind noise reduction for multisensory signals using ICA and subspace filtering, with application to EEG analysis , 2002, Biological Cybernetics.