Online rotor mixed fault diagnosis way based on spectrum analysis of instantaneous power in squirrel cage induction motors

Broken rotor bars and eccentricity are common faults in squirrel cage induction motors. These two faults usually occur simultaneously. This paper will deal with this kind of mixed fault. It is well known that the characteristic frequency of broken bars in the stator line current of a squirrel cage induction motor is very near to that of the fundamental component. In the spectrum of the stator line current, the characteristic components related to broken rotor bars are always submerged by the fundamental one, and it is difficult to detect the broken bar fault at an early stage. In our work, instantaneous power of the motor is used as the quantity to be monitored. Theoretical analysis indicates that the spectrum of ac level of the spectrum of the instantaneous power is clear from any component at the fundamental supply frequency, and the fault characteristics can be highlighted, which is effective toward the separation of mixed faults and the quantification of the fault extent. Experimental results have demonstrated the effectiveness of the proposed technique.

[1]  F. Filippetti,et al.  Quantitative evaluation of induction motor broken bars by means of electrical signature analysis , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[2]  Peter Tavner,et al.  Condition monitoring of electrical machines , 1987 .

[3]  David G. Dorrell,et al.  On-line current monitoring to diagnose airgap eccentricity in large three-phase induction motors-industrial case histories verify the predictions , 1999 .

[4]  R. Maier,et al.  Protection of squirrel cage induction motor utilizing instantaneous power and phase information , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[5]  Alberto Bellini,et al.  Quantitative Evaluation of Induction Motor Broken Bars By Means of Electric Signals Signatures , 2001 .

[6]  Giovanni Franceschini,et al.  Development of expert system knowledge base to on-line diagnosis of rotor electrical faults of induction motors , 1992, Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting.

[7]  K.W.E. Cheng,et al.  Condition monitoring of rotor faults in induction motors by injection of low frequency signals into the supply , 1998 .

[8]  S. F. Legowski,et al.  Diagnostics of mechanical abnormalities in induction motors using instantaneous electric power , 1997, 1997 IEEE International Electric Machines and Drives Conference Record.

[9]  A.J. Marques Cardoso,et al.  Rotor cage fault diagnosis in three-phase induction motors, by Park's vector approach , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[10]  E. S. Saraiva,et al.  Computer aided detection of airgap eccentricity in operating three-phase induction motors, by Park's vector approach , 1991, Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting.

[11]  H.A. Toliyat,et al.  Mixed eccentricity in three phase induction machines: analysis, simulation and experiments , 2002, Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344).

[12]  M. Dalva,et al.  A survey of faults on induction motors in offshore oil industry, petrochemical industry, gas terminals and oil refineries , 1994, Proceedings of IEEE Petroleum and Chemical Industry Technical Conference (PCIC '94).

[13]  S. Ahmed,et al.  Detection of Rotor Slot and Other Eccentricity-Related Harmonics in a Three-Phase Induction Motor with Different Rotor Cages , 2001, IEEE Power Engineering Review.

[14]  Mohamed El Hachemi Benbouzid A review of induction motors signature analysis as a medium for faults detection , 2000, IEEE Trans. Ind. Electron..

[15]  Antonio J. Marques Cardoso,et al.  Inter-turn stator winding fault diagnosis in three-phase induction motors, by Park's Vector approach , 1997 .

[16]  A.M. Trzynadlowski,et al.  Instantaneous stator power as a medium for the signature analysis of induction motors , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[17]  F. Filippetti,et al.  Broken bar detection in induction machines: comparison between current spectrum approach and parameter estimation approach , 1994, Proceedings of 1994 IEEE Industry Applications Society Annual Meeting.

[18]  Antonio J. Marques Cardoso,et al.  Rotor cage fault diagnosis in three-phase induction motors by the total instantaneous power spectral analysis , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[19]  Christian Kral,et al.  Sequences of field-oriented control for the detection of faulty rotor bars in induction machines-the Vienna Monitoring Method , 1998, IEEE Trans. Ind. Electron..

[20]  David G. Dorrell,et al.  ON-LINE CURRENT MONITORING TO DIAGNOSE AIRGAP ECCENTRICITY HISTORIES VERIFY THE PREDICTIONS IN LARGE THREE-PHASE INDUCTION MOTORS - INDUSTRIAL CASE , 1999 .

[21]  G. B. Kliman,et al.  Noninvasive detection of broken rotor bars in operating induction motors , 1988 .

[22]  Gerald Burt Kliman,et al.  Methods of Motor Current Signature Analysis , 1992 .

[23]  A. J. Marques Cardoso,et al.  Rotor Cage Fault Diagnosis in Three-Phase Induction Motors by Extended Park's Vector Approach , 2000 .