Biaxial tension of fibrous tissue: using finite element methods to address experimental challenges arising from boundary conditions and anisotropy.

Planar biaxial tension remains a critical loading modality for fibrous soft tissue and is widely used to characterize tissue mechanical response, evaluate treatments, develop constitutive formulas, and obtain material properties for use in finite element studies. Although the application of tension on all edges of the test specimen represents the in situ environment, there remains a need to address the interpretation of experimental results. Unlike uniaxial tension, in biaxial tension the applied forces at the loading clamps do not transmit fully to the region of interest (ROI), which may lead to improper material characterization if not accounted for. In this study, we reviewed the tensile biaxial literature over the last ten years, noting experimental and analysis challenges. In response to these challenges, we used finite element simulations to quantify load transmission from the clamps to the ROI in biaxial tension and to formulate a correction factor that can be used to determine ROI stresses. Additionally, the impact of sample geometry, material anisotropy, and tissue orientation on the correction factor were determined. Large stress concentrations were evident in both square and cruciform geometries and for all levels of anisotropy. In general, stress concentrations were greater for the square geometry than the cruciform geometry. For both square and cruciform geometries, materials with fibers aligned parallel to the loading axes reduced stress concentrations compared to the isotropic tissue, resulting in more of the applied load being transferred to the ROI. In contrast, fiber-reinforced specimens oriented such that the fibers aligned at an angle to the loading axes produced very large stress concentrations across the clamps and shielding in the ROI. A correction factor technique was introduced that can be used to calculate the stresses in the ROI from the measured experimental loads at the clamps. Application of a correction factor to experimental biaxial results may lead to more accurate representation of the mechanical response of fibrous soft tissue.

[1]  D. Cortes,et al.  A nonlinear biphasic viscohyperelastic model for articular cartilage. , 2006, Journal of biomechanics.

[2]  J. Humphrey,et al.  Determination of a constitutive relation for passive myocardium: I. A new functional form. , 1990, Journal of biomechanical engineering.

[3]  Wei Sun,et al.  Effects of boundary conditions on the estimation of the planar biaxial mechanical properties of soft tissues. , 2005, Journal of biomechanical engineering.

[4]  E. Nauman,et al.  Multiscale strain analysis of tissue equivalents using a custom-designed biaxial testing device. , 2012, Biophysical journal.

[5]  Peter Wriggers,et al.  Large strain analysis of soft biological membranes: Formulation and finite element analysis , 1996 .

[6]  Y. Lanir Constitutive equations for the lung tissue. , 1983, Journal of biomechanical engineering.

[7]  M. Segal,et al.  Biaxial Testing of Human Annulus Fibrosus and Its Implications for a Constitutive Formulation , 2004, Annals of Biomedical Engineering.

[8]  A. Yoganathan,et al.  Planar Biaxial Creep and Stress Relaxation of the Mitral Valve Anterior Leaflet , 2006, Annals of Biomedical Engineering.

[9]  Wei Sun,et al.  Multiaxial mechanical behavior of biological materials. , 2003, Annual review of biomedical engineering.

[10]  John G Flanagan,et al.  Biaxial mechanical testing of human sclera. , 2010, Journal of biomechanics.

[11]  Victor H Barocas,et al.  Image-based multiscale modeling predicts tissue-level and network-level fiber reorganization in stretched cell-compacted collagen gels , 2009, Proceedings of the National Academy of Sciences.

[12]  C. R. Ethier,et al.  Strain uniformity in biaxial specimens is highly sensitive to attachment details. , 2009, Journal of biomechanical engineering.

[13]  D. Elliott,et al.  Extra-fibrillar matrix mechanics of annulus fibrosus in tension and compression , 2012, Biomechanics and modeling in mechanobiology.

[14]  Ramesh Raghupathy,et al.  A closed-form structural model of planar fibrous tissue mechanics. , 2009, Journal of biomechanics.

[15]  Spencer E. Szczesny,et al.  Biaxial tensile testing and constitutive modeling of human supraspinatus tendon , 2012, 2012 38th Annual Northeast Bioengineering Conference (NEBEC).

[16]  C Scheffer,et al.  Application of finite element analysis to the design of tissue leaflets for a percutaneous aortic valve. , 2009, Journal of the mechanical behavior of biomedical materials.

[17]  J. Humphrey,et al.  Determination of a constitutive relation for passive myocardium: II. Parameter estimation. , 1990, Journal of biomechanical engineering.

[18]  M. Sacks,et al.  Biaxial mechanical properties of the natural and glutaraldehyde treated aortic valve cusp--Part I: Experimental results. , 2000, Journal of biomechanical engineering.

[19]  Victor H Barocas,et al.  Planar biaxial mechanical behavior of bioartificial tissues possessing prescribed fiber alignment. , 2009, Journal of biomechanical engineering.

[20]  A. Yoganathan,et al.  Biaixal Stress–Stretch Behavior of the Mitral Valve Anterior Leaflet at Physiologic Strain Rates , 2006, Annals of Biomedical Engineering.

[21]  J. Callaghan,et al.  An examination of the influence of strain rate on subfailure mechanical properties of the annulus fibrosus. , 2010, Journal of biomechanical engineering.

[22]  D. Elliott,et al.  Theoretical and uniaxial experimental evaluation of human annulus fibrosus degeneration. , 2009, Journal of biomechanical engineering.

[23]  M. Sacks,et al.  Simulated bioprosthetic heart valve deformation under quasi-static loading. , 2005, Journal of biomechanical engineering.

[24]  Wei Sun,et al.  Biomechanical characterization of aortic valve tissue in humans and common animal models. , 2012, Journal of biomedical materials research. Part A.

[25]  Elena S. Di Martino,et al.  Biaxial mechanical modeling of the small intestine. , 2011, Journal of the mechanical behavior of biomedical materials.

[26]  Benjamin J. Ellis,et al.  FEBio: finite elements for biomechanics. , 2012, Journal of biomechanical engineering.

[27]  Dalin Tang,et al.  Planar biaxial characterization of diseased human coronary and carotid arteries for computational modeling. , 2012, Journal of biomechanics.

[28]  S. Waldman,et al.  Boundary conditions during biaxial testing of planar connective tissues. Part 1: Dynamic Behavior , 2002, Journal of materials science. Materials in medicine.

[29]  Wei Sun,et al.  Finite element implementation of a generalized Fung-elastic constitutive model for planar soft tissues , 2005, Biomechanics and modeling in mechanobiology.

[30]  Y Lanir,et al.  Two-dimensional mechanical properties of rabbit skin. II. Experimental results. , 1974, Journal of Biomechanics.

[31]  Y Lanir,et al.  Two-dimensional mechanical properties of rabbit skin. I. Experimental system. , 1974, Journal of biomechanics.

[32]  Dawn M Elliott,et al.  The role of fiber-matrix interactions in a nonlinear fiber-reinforced strain energy model of tendon. , 2005, Journal of biomechanical engineering.

[33]  Y. Fung,et al.  The stress-strain relationship for the skin. , 1976, Journal of biomechanics.

[34]  S. Waldman,et al.  Effect of sample geometry on the apparent biaxial mechanical behaviour of planar connective tissues. , 2005, Biomaterials.

[35]  B H Smaill,et al.  An assessment of the mechanical properties of leaflets from four second-generation porcine bioprostheses with biaxial testing techniques. , 1989, The Journal of thoracic and cardiovascular surgery.

[36]  V C Mow,et al.  The nonlinear characteristics of soft gels and hydrated connective tissues in ultrafiltration. , 1990, Journal of biomechanics.

[37]  Y Lanir,et al.  A structural theory for the homogeneous biaxial stress-strain relationships in flat collagenous tissues. , 1979, Journal of biomechanics.

[38]  Michael W. R. Holmes,et al.  Biomechanical properties of the transverse carpal ligament under biaxial strain , 2012, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[39]  Edward A. Sander,et al.  Image-based biomechanics of collagen-based tissue equivalents , 2009, IEEE Engineering in Medicine and Biology Magazine.

[40]  Dawn M Elliott,et al.  Degeneration affects the fiber reorientation of human annulus fibrosus under tensile load. , 2006, Journal of biomechanics.

[41]  Sounok Sen,et al.  Human annulus fibrosus material properties from biaxial testing and constitutive modeling are altered with degeneration , 2011, Biomechanics and Modeling in Mechanobiology.

[42]  M. Sacks,et al.  Biaxial mechanical properties of the native and glutaraldehyde-treated aortic valve cusp: Part II--A structural constitutive model. , 2000, Journal of biomechanical engineering.

[43]  D. Elliott,et al.  Effect of fiber orientation and strain rate on the nonlinear uniaxial tensile material properties of tendon. , 2003, Journal of biomechanical engineering.

[44]  Y Lanir,et al.  Plausibility of structural constitutive equations for swelling tissues--implications of the C-N and S-E conditions. , 1996, Journal of biomechanical engineering.

[45]  Yanhang Zhang,et al.  Experimental and Modeling Study of Collagen Scaffolds with the Effects of Crosslinking and Fiber Alignment , 2011, International journal of biomaterials.

[46]  Image-based multiscale structural models of fibrous engineered tissues , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[47]  A. Spencer,et al.  Deformations of fibre-reinforced materials, , 1972 .