Parametric Power Spectral Density Analysis of Noise from Instrumentation in MALDI TOF Mass Spectrometry

Noise in mass spectrometry can interfere with identification of the biochemical substances in the sample. For example, the electric motors and circuits inside the mass spectrometer or in nearby equipment generate random noise that may distort the true shape of mass spectra. This paper presents a stochastic signal processing approach to analyzing noise from electrical noise sources (i.e., noise from instrumentation) in MALDI TOF mass spectrometry. Noise from instrumentation was hypothesized to be a mixture of thermal noise, 1/f noise, and electric or magnetic interference in the instrument. Parametric power spectral density estimation was conducted to derive the power distribution of noise from instrumentation with respect to frequencies. As expected, the experimental results show that noise from instrumentation contains 1/f noise and prominent periodic components in addition to thermal noise. These periodic components imply that the mass spectrometers used in this study may not be completely shielded from the internal or external electrical noise sources. However, according to a simulation study of human plasma mass spectra, noise from instrumentation does not seem to affect mass spectra significantly. In conclusion, analysis of noise from instrumentation using stochastic signal processing here provides an intuitive perspective on how to quantify noise in mass spectrometry through spectral modeling.

[1]  Heping Zhang,et al.  Tree‐based disease classification using protein data , 2003, Proteomics.

[2]  H. Akaike A new look at the statistical model identification , 1974 .

[3]  M. Trosset,et al.  Enhancement of sensitivity and resolution of surface-enhanced laser desorption/ionization time-of-flight mass spectrometric records for serum peptides using time-series analysis techniques. , 2005, Clinical chemistry.

[4]  Xiwu Lin,et al.  Megavariate data analysis of mass spectrometric proteomics data using latent variable projection method , 2003, Proteomics.

[5]  N. Anderson,et al.  The Human Plasma Proteome: History, Character, and Diagnostic Prospects , 2003, Molecular & Cellular Proteomics.

[6]  C. A. Hastings,et al.  New algorithms for processing and peak detection in liquid chromatography/mass spectrometry data. , 2002, Rapid communications in mass spectrometry : RCM.

[7]  P. Schellhammer,et al.  Data Reduction Using a Discrete Wavelet Transform in Discriminant Analysis of Very High Dimensionality Data , 2003, Biometrics.

[8]  Somnath Datta,et al.  Standardization and denoising algorithms for mass spectra to classify whole-organism bacterial specimens , 2004, Bioinform..

[9]  M. Campa,et al.  Analysis of human serum proteins by liquid phase isoelectric focusing and matrix‐assisted laser desorption/ionization‐mass spectrometry , 2003, Proteomics.

[10]  N. Anderson,et al.  The Human Plasma Proteome , 2002, Molecular & Cellular Proteomics.

[11]  Jeffrey S. Morris,et al.  Understanding the characteristics of mass spectrometry data through the use of simulation , 2005, Cancer informatics.

[12]  Solomon Kullback,et al.  Information Theory and Statistics , 1960 .

[13]  J. Wiza Microchannel plate detectors , 1979 .

[14]  T. Rejtar,et al.  A universal denoising and peak picking algorithm for LC-MS based on matched filtration in the chromatographic time domain. , 2003, Analytical chemistry.

[15]  Stephen A. Dyer,et al.  Digital signal processing , 2018, 8th International Multitopic Conference, 2004. Proceedings of INMIC 2004..

[16]  David R. Anderson,et al.  Understanding AIC and BIC in Model Selection , 2004 .

[17]  A. Pothen,et al.  Protocols for disease classification from mass spectrometry data , 2003, Proteomics.

[18]  Stephen A. Martin,et al.  On the initial velocity of ions generated by matrix-assisted laser desorption ionization and its effect on the calibration of delayed extraction time-of-flight mass spectra , 1997 .

[19]  J. Glimm,et al.  Detection of cancer-specific markers amid massive mass spectral data , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[20]  Balaji Krishnapuram,et al.  Identification of differentially expressed proteins using MALDI-TOF mass spectra , 2003, The Thrity-Seventh Asilomar Conference on Signals, Systems & Computers, 2003.

[21]  Henry W. Ott,et al.  Noise Reduction Techniques in Electronic Systems , 1976 .

[22]  Jeffrey S. Morris,et al.  Improved peak detection and quantification of mass spectrometry data acquired from surface‐enhanced laser desorption and ionization by denoising spectra with the undecimated discrete wavelet transform , 2005, Proteomics.

[23]  Ronald Beavis,et al.  Velocity distributions of intact high mass polypeptide molecule ions produced by matrix assisted laser desorption , 1991 .

[24]  Jeffrey S. Morris,et al.  A comprehensive approach to the analysis of matrix‐assisted laser desorption/ionization‐time of flight proteomics spectra from serum samples , 2003, Proteomics.

[25]  Milt Statheropoulos,et al.  Noise reduction of fast, repetitive GC/MS measurements using principal component analysis (PCA) , 1999 .

[26]  Russ Wolfinger,et al.  Generalizable mass spectrometry mining used to identify disease state biomarkers from blood serum , 2003, Proteomics.

[27]  Piet M. T. Broersen,et al.  Generating data with prescribed power spectral density , 2003, IEEE Trans. Instrum. Meas..

[28]  Piet M. T. Broersen,et al.  The Burg algorithm for segments , 2000, IEEE Trans. Signal Process..

[29]  Hua Lin,et al.  Quantifying reproducibility for differential proteomics: noise analysis for protein liquid chromatography-mass spectrometry of human serum , 2004, Bioinform..

[30]  Jeffrey S. Morris,et al.  Quality control and peak finding for proteomics data collected from nipple aspirate fluid by surface-enhanced laser desorption and ionization. , 2003, Clinical chemistry.