The effects of experimental tear film removal on corneal surface regularity and barrier function.

PURPOSE To evaluate corneal surface regularity and asymmetry, corneal thickness, barrier function, and contrast sensitivity after experimental removal of the precorneal tear layer. DESIGN Prospective, clinic-based, nonrandomized (self-controlled) comparative trial. PARTICIPANTS Six eyes of six healthy volunteers (three males, three females; age range, 29-40 years). METHODS A precorneal tear lesion was created by pressing a sterile Biopore (Millipore, Bedford, MA) Teflon membrane against the central cornea. Corneal topography with both the Topographic Modeling System (TMS-1; Computed Anatomy, Tomey Technology, Cambridge, MA) and the Orbscan (Orbscan Inc., Salt Lake City, UT) were performed before the lesion was created and 30 seconds, 1 hour, and 4 hours after the lesion was created. Surface regularity and surface asymmetry indices were evaluated by the TMS-1 topography system. Maximum and minimum keratometric readings, corneal fluorescein staining, contrast sensitivity, and corneal thickness were evaluated before and after the tear lesion. Cytologic membranes were stained for MUC4 mucin using an indirect immunofluorescent staining technique. Confocal microscopy was performed to evaluate the integrity of the corneal epithelium in two eyes. Analysis of variance with polynomial contrasts was used to examine time trends of the outcome variables. MAIN OUTCOME MEASURES The change in corneal surface regularity and asymmetry indices, corneal thickness, permeability to fluorescein dye, and contrast sensitivity before and after the lesion was made were compared. RESULTS The corneal epithelium in the area of the lesion showed intense fluorescein staining 30 seconds postlesion but appeared normal by 4 hours. Confluent, homogeneous staining for MUC4 mucin was observed on the membranes used to create the lesion in all cases. The surface regularity index measured with the TMS-1 increased after the lesion was created and decreased toward normal by 4 hours (P = 0.017). Corneal thickness measured by the Orbscan instrument significantly increased in the central (P = 0.001), superior (P = 0.006), inferotemporal (P < 0.001) and superotemporal (P = 0.001) cornea immediately following the lesion and returned to normal by 4 hours. The lesion caused a decrease in visual acuity at 6.30%, 4% and 2.5% contrast sensitivities 1 hour postlesion and these measurements returned to prelesion values by 4 hours (P = 0.085, P = 0.005, P = 0.043). CONCLUSIONS The precorneal tear layer serves as a permeability barrier and is essential for maintaining a smooth quality optical surface.

[1]  S Tsukahara,et al.  Structure and composition of rat precorneal tear film. A study by an in vivo cryofixation. , 1997, Investigative ophthalmology & visual science.

[2]  M. Iester,et al.  Low spatial-contrast sensitivity in dry eyes. , 1998, Cornea.

[3]  D. Korb,et al.  Histochemical analysis of secretory vesicles in nongoblet conjunctival epithelial cells , 1985, Acta ophthalmologica.

[4]  T. Inatomi,et al.  Mucin genes expressed by the ocular surface Epithelium , 1997, Progress in Retinal and Eye Research.

[5]  S. Tseng,et al.  Sialomucin complex at the rat ocular surface: a new model for ocular surface protection. , 1998, The Biochemical journal.

[6]  C. Dawson,et al.  Demonstration of the mucous layer of the tear film by electron microscopy. , 1985, Investigative ophthalmology & visual science.

[7]  W. Feuer,et al.  Evaluation of Subjective Assessments and Objective Diagnostic Tests for Diagnosing Tear‐Film Disorders Known to Cause Ocular Irritation , 1998, Cornea.

[8]  W. Feuer,et al.  Correlation of tear fluorescein clearance and Schirmer test scores with ocular irritation symptoms. , 1999, Ophthalmology.

[9]  P. Dilly On the nature and the role of the subsurface vesicles in the outer epithelial cells of the conjunctiva. , 1985, The British journal of ophthalmology.

[10]  S. Klyce,et al.  Advances in the analysis of corneal topography. , 1991, Survey of ophthalmology.

[11]  I. Gipson,et al.  Alteration of mucin in human conjunctival epithelia in dry eye. , 1998, Investigative ophthalmology & visual science.

[12]  W M Petroll,et al.  Quantitative three-dimensional confocal imaging of the cornea in situ and in vivo: system design and calibration. , 2006, Scanning.

[13]  S. Pflugfelder,et al.  Corneal surface regularity and the effect of artificial tears in aqueous tear deficiency. , 1999, Ophthalmology.

[14]  S. Tseng,et al.  Correlation of goblet cell density and mucosal epithelial membrane mucin expression with rose bengal staining in patients with ocular irritation. , 1997, Ophthalmology.

[15]  T. Inatomi,et al.  Expression of secretory mucin genes by human conjunctival epithelia. , 1996, Investigative ophthalmology & visual science.

[16]  S. Pflugfelder,et al.  Corneal thickness is reduced in dry eye. , 1999, Cornea.

[17]  F. Campbell,et al.  Study of human precorneal tear film thickness and structure using laser interferometry. , 1992, Investigative ophthalmology & visual science.

[18]  S. Tseng,et al.  Paracellular permeability of corneal and conjunctival epithelia. , 1989, Investigative ophthalmology & visual science.

[19]  M A Lemp,et al.  Tear physiology and dry eyes. , 1977, Survey of ophthalmology.

[20]  L. Sobrin,et al.  Tear fluid gelatinase B activity correlates with IL-1alpha concentration and fluorescein clearance in ocular rosacea. , 1999, Investigative ophthalmology & visual science.

[21]  S D Klyce,et al.  Quantitative descriptors of corneal shape derived from computer-assisted analysis of photokeratographs. , 1989, Refractive & corneal surgery.

[22]  S. Pflugfelder,et al.  Sjögren's syndrome: cytokine and Epstein-Barr viral gene expression within the conjunctival epithelium. , 1994, Investigative ophthalmology & visual science.

[23]  S D Klyce,et al.  Quantitative descriptors of corneal topography. A clinical study. , 1991, Archives of ophthalmology.

[24]  K. Carraway,et al.  Detection of sialomucin complex (MUC4) in human ocular surface epithelium and tear fluid. , 2000, Investigative ophthalmology & visual science.

[25]  M. Göbbels,et al.  Corneal epithelial permeability of dry eyes before and after treatment with artificial tears. , 1992, Ophthalmology.