GPU accelerated regional lung air volume measurements from phase contrast X-ray images

Phase contrast X-ray imaging can provide significantly enhanced visibility of soft tissues over absorption contrast imaging with spatial resolution on the micron scale. These characteristics have enabled the visualisation of lungs aerating at birth in real time. We have developed techniques to measure regional lung air volume from these images to help develop methods for safely ventilating the lungs of preterm infants. However, analyzing a large sequence of image data requires considerable computation time on traditional desktop computers. Real-time feedback of the regional ventilation would greatly benefit researches to optimize ventilation strategies. The present paper describes methods for improving the execution time of the lung volume measurements using graphics processing units (GPUs). We tested the performance of the GPU-accelerated lung volume computations using two different GPUs and compared the results with two CPUs. An overall speedup of 1.75–14.12× was achieved if an absorption contrast-based computation was used for volumetric computation, while a 2.43–15.78× speedup was attained in the case of a more compute bound phase retrieval technique. This speedup enabled us to perform lung air volume reconstruction on a local computer with the analysis taking only a few minutes, which is very helpful to guide our experiments in the laboratory. We also show that the accuracy of the GPU-based lung volume measurements was in excellent agreement with the CPU-based counterpart.

[1]  Kenneth Moreland,et al.  The FFT on a GPU , 2003, HWWS '03.

[2]  K K W Siu,et al.  Dynamic measures of regional lung air volume using phase contrast x-ray imaging , 2008, Physics in medicine and biology.

[3]  P. Davis,et al.  Effect of Sustained Inflation Length on Establishing Functional Residual Capacity at Birth in Ventilated Premature Rabbits , 2009, Pediatric Research.

[4]  J. Xu OpenCL – The Open Standard for Parallel Programming of Heterogeneous Systems , 2009 .

[5]  K. Nugent Coherent methods in the X-ray sciences , 2009, 0908.3064.

[6]  Kentaro Uesugi,et al.  Surfactant Increases the Uniformity of Lung Aeration at Birth in Ventilated Preterm Rabbits , 2011, Pediatric Research.

[7]  Jens H. Krüger,et al.  A Survey of General‐Purpose Computation on Graphics Hardware , 2007, Eurographics.

[8]  Simon Portegies Zwart,et al.  High-performance direct gravitational N-body simulations on graphics processing units , 2007, astro-ph/0702058.

[9]  Kentaro Uesugi,et al.  Phase contrast image segmentation using a Laue analyser crystal , 2011, Physics in medicine and biology.

[10]  Jens H. Krüger,et al.  GPGPU: general purpose computation on graphics hardware , 2004, SIGGRAPH '04.

[11]  Andreas Fouras,et al.  The past, present, and future of x-ray technology for in vivo imaging of function and form , 2009 .

[12]  P. Davis,et al.  Establishing Functional Residual Capacity at Birth: The Effect of Sustained Inflation and Positive End-Expiratory Pressure in a Preterm Rabbit Model , 2009, Pediatric Research.

[13]  Anders Brahme,et al.  Development of phase-contrast X-ray imaging techniques and potential medical applications. , 2008, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[14]  Sanjeev Arora,et al.  Computational Complexity: A Modern Approach , 2009 .

[15]  M. Kitchen,et al.  A high precision recipe for correcting images distorted by a tapered fiber optic , 2010 .

[16]  Tiow Seng Tan,et al.  Computing two-dimensional Delaunay triangulation using graphics hardware , 2008, I3D '08.

[17]  S. Wilkins,et al.  Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object , 2002, Journal of microscopy.

[18]  Y. Kohmura,et al.  Refraction-enhanced x-ray imaging of mouse lung using synchrotron radiation source. , 1999, Medical physics.

[19]  Kentaro Uesugi,et al.  IMAGING LUNG AERATION AND LUNG LIQUID CLEARANCE AT BIRTH USING PHASE CONTRAST X‐RAY IMAGING , 2009, Clinical and experimental pharmacology & physiology.

[20]  Yugang Min,et al.  A multi-GPU real-time dose simulation software framework for lung radiotherapy , 2012, International Journal of Computer Assisted Radiology and Surgery.