Improvement of Dynamic Behavior of Shunt Active Power Filter Using Fuzzy Instantaneous Power Theory

Dynamic behavior of the harmonic detection part of an active power filter (APF) has an essential role in filter compensation performances during transient conditions. Instantaneous power (p?q) theory is extensively used to design harmonic detectors for active filters. Large overshoot of p?q theory method deteriorates filter response at a large and rapid load change. In this study the harmonic estimation of an APF during transient conditions for balanced three-phase nonlinear loads is conducted. A novel fuzzy instantaneous power (FIP) theory is proposed to improve conventional p?q theory dynamic performances during transient conditions to adapt automatically to any random and rapid nonlinear load change. Adding fuzzy rules in p?q theory improves the decomposition of the alternating current components of active and reactive power signals and develops correct reference during rapid and random current variation. Modifying p?q theory internal high-pass filter performance using fuzzy rules without any drawback is a prospect. In the simulated system using MATLAB/SIMULINK, the shunt active filter is connected to a rapidly time-varying nonlinear load. The harmonic detection parts of the shunt active filter are developed for FIP theory-based and p?q theory-based algorithms. The harmonic detector hardware is also developed using the TMS320F28335 digital signal processor and connected to a laboratory nonlinear load. The software is developed for FIP theory-based and p?q theory-based algorithms. The simulation and experimental tests results verify the ability of the new technique in harmonic detection of rapid changing nonlinear loads.

[1]  Asheesh K. Singh,et al.  A simple fuzzy logic based robust active power filter for harmonics minimization under random load variation , 2007 .

[2]  Wook Hyun Kwon,et al.  Computational complexity of general fuzzy logic control and its simplification for a loop controller , 2000, Fuzzy Sets Syst..

[3]  Mauricio Aredes,et al.  New concepts of instantaneous active and reactive powers in electrical systems with generic loads , 1993 .

[4]  H. Akagi,et al.  The p-q theory for active filter control: some problems and solutions , 2004 .

[5]  Li Hongda,et al.  Active power filter simulation based on instantaneous reactive power theory and the PWM hysteresis control mode , 2011, IEEE 2011 10th International Conference on Electronic Measurement & Instruments.

[6]  Hirofumi Akagi,et al.  Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components , 1984, IEEE Transactions on Industry Applications.

[7]  S. Arumugam,et al.  A Comparative Performance Analysis of Four Control Algorithms for a Three Phase Shunt Active Power Filter , 2010 .

[8]  Rafik Neji,et al.  Experimental Investigations for Thermal Mutual Evaluation in Multi-Chip Modules , 2014 .

[9]  Mohammad Haseeb Khan,et al.  Reduced rule fuzzy logic controller for performance improvement of process control , 2013, 2013 IEEE CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGIES.

[10]  Leszek S. Czarnecki Effect of supply voltage asymmetry on IRP p-q-based switching compensator control , 2010 .

[11]  Júlio S. Martins,et al.  Active filters with control based on the p-q theory , 2000 .

[12]  Sakshi Bangia,et al.  A NOVEL CONTROL STRATEGY FOR ENHANCEMENT OF POWER QUALITY USING FUZZY LOGIC , 2012 .

[13]  L.S. Czarnecki,et al.  Instantaneous reactive power p-q theory and power properties of three-phase systems , 2006, IEEE Transactions on Power Delivery.

[14]  R. Gupta,et al.  Shunt active power filter as front end converter for DC loads , 2012, 2012 IEEE 5th India International Conference on Power Electronics (IICPE).

[15]  K-L. Areerak,et al.  A Literature Survey of Neural Network Applications for Shunt Active Power Filters , 2011 .

[16]  E. Babaei,et al.  Enhancement of instantaneous power theory under unbalanced grid voltages condition using positive sinusoidal signal regulator , 2012, 2012 IEEE 5th India International Conference on Power Electronics (IICPE).

[17]  Mukhtiar Ali Unar,et al.  Estimation of Compensation Current Reference using Fuzzy Logic Controller for Three-Phase Hybrid Active Power Filter , 2012 .

[18]  F. Blaabjerg,et al.  Evaluation of harmonic detection methods for active power filter applications , 2005, Twentieth Annual IEEE Applied Power Electronics Conference and Exposition, 2005. APEC 2005..

[19]  Asheesh K. Singh,et al.  Approximated fuzzy logic controlled shunt active power filter for improved power quality , 2013, Expert Syst. J. Knowl. Eng..

[20]  E.R. Cadaval,et al.  Comparison of Control Strategies for Shunt Active Power Filters in Three-Phase Four-Wire Systems , 2007, IEEE Transactions on Power Electronics.

[21]  Ming Li,et al.  A Novel Single Phase Synchronous Reference Frame Phase-Locked Loop with a Constant Zero Orthogonal Component , 2014 .

[22]  Alexandru Bitoleanu,et al.  p–q power theory: Some theoretical and practical aspects , 2010, 2010 International School on Nonsinusoidal Currents and Compensation.