The Rise and Fall of Access Blood Flow Surveillance in Arteriovenous Fistulas

Vascular access blood flow (Qa) surveillance has been described as a typical false paradigm, an example of how new tests are sometimes adopted even without good‐quality evidence of their benefits. This may be true for grafts, but not necessarily for arteriovenous fistulas. We reviewed the literature on Qa surveillance in fistulas to see whether it complies with the World Health Organization's criteria for screening tests. Measuring Qa has a fairly good reproducibility. Qa shows an excellent‐to‐good accuracy for stenosis being the only bedside screening test that achieves a very high sensitivity while retaining a fair‐to‐good positive predictive value for Qa thresholds of 600 ml/minute or higher associated with a >25% drop in Qa, or findings suggesting stenosis on physical examination. The accuracy of Qa in predicting thrombosis is hard to establish because of the heterogeneity of published studies, though a Qa of 300 ml/minute seems the most reliable cutoff. Qa surveillance affords a significant 2‐ to 3‐fold reduction in the risk of thrombosis by comparison with clinical monitoring alone when Qa criteria highly sensitive to stenosis are considered, regardless of the study design (randomized controlled trials, cohort studies with concurrent or historic controls). Using highly sensitive Qa screening criteria also halves the risk of access loss, although this effect is not statistically significant. Our analysis strongly suggests that Qa surveillance is an effective method for screening mature fistulas, though further, appropriately designed studies are needed to fully elucidate its benefits and cost effectiveness.

[1]  L. Moist,et al.  Vascular access surveillance: an ongoing controversy. , 2012, Kidney international.

[2]  Wu-chang Yang,et al.  Variable pump flow-based Doppler ultrasound method: a novel approach to the measurement of access flow in hemodialysis patients. , 2004, Journal of the American Society of Nephrology : JASN.

[3]  P. Caramori,et al.  Maintenance of Hemodialysis Arteriovenous Fistulas by an Interventional Strategy , 2009, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[4]  Prabir Roy-Chaudhury,et al.  Vascular access in haemodialysis: strengthening the Achilles' heel , 2013, Nature Reviews Nephrology.

[5]  N M Krivitski,et al.  Theory and validation of access flow measurement by dilution technique during hemodialysis. , 1995, Kidney international.

[6]  L. Salman,et al.  Accuracy of physical examination in the detection of arteriovenous fistula stenosis. , 2007, Clinical journal of the American Society of Nephrology : CJASN.

[7]  R. Atkins,et al.  Does monthly native arteriovenous fistula blood-flow surveillance detect significant stenosis--a randomized controlled trial. , 2006, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[8]  Clinical practice guidelines for vascular access. , 2006, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[9]  Ja Wilson,et al.  Principles and practice of screening for disease , 1968 .

[10]  J. Arrieta,et al.  Guía de acceso vascular en hemodiálisis , 2005 .

[11]  J. Leypoldt,et al.  Noninvasive transcutaneous determination of access blood flow rate. , 2001, Kidney international.

[12]  Theo Stijnen,et al.  Advanced methods in meta‐analysis: multivariate approach and meta‐regression , 2002, Statistics in medicine.

[13]  N. Laird,et al.  Meta-analysis in clinical trials. , 1986, Controlled clinical trials.

[14]  K. Leunissen,et al.  Impact of a quality improvement programme based on vascular access flow monitoring on costs, access occlusion and access failure. , 2006, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[15]  G. Heinze,et al.  Flow monitoring: performance characteristics of ultrasound dilution versus color Doppler ultrasound compared with fistulography. , 2003, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[16]  J. Rubin,et al.  Analysis of variable flow Doppler hemodialysis access flow measurements and comparison with ultrasound dilution. , 2001, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[17]  A. Tielbeek,et al.  Stenosis detection in failing hemodialysis access fistulas and grafts: comparison of color Doppler ultrasonography, contrast-enhanced magnetic resonance angiography, and digital subtraction angiography. , 2005, Journal of vascular surgery.

[18]  S. Yilmaz,et al.  Native Arteriovenous Fistulas: Correlation of Intra‐Access Blood Flow with Characteristics of Stenoses Found During Diagnostic Angiography , 2007, Seminars in dialysis.

[19]  M. Tonelli,et al.  Access flow in arteriovenous accesses by optodilutional and ultrasound dilution methods. , 2005, American Journal of Kidney Diseases.

[20]  P. Snelling,et al.  Prediction of failure of native arteriovenous fistulas using ‘on‐line’ fistula flow measurements , 2005, Nephrology.

[21]  F. Gotch,et al.  Measurement of blood access flow rate during hemodialysis from conductivity dialysance. , 1999, ASAIO journal.

[22]  J. Sands,et al.  Intervention based on monthly monitoring decreases hemodialysis access thrombosis. , 1999, ASAIO journal.

[23]  T A Ikizler,et al.  Vascular access blood flow monitoring reduces access morbidity and costs. , 2001, Kidney international.

[24]  K. Polkinghorne Vascular access surveillance , 2008 .

[25]  M. Perazella,et al.  Vascular Access Surveillance: Evaluation of Combining Dynamic Venous Pressure and Vascular Access Blood Flow Measurements , 2003, American Journal of Nephrology.

[26]  A. Lupo,et al.  Should current criteria for detecting and repairing arteriovenous fistula stenosis be reconsidered? Interim analysis of a randomized controlled trial. , 2014, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[27]  J. R. Raymond,et al.  Prevention of hemodialysis fistula thrombosis. Early detection of venous stenoses. , 1989, Kidney international.

[28]  S. Eiam‐Ong,et al.  A novel simple hemoglobin dilution technique to measure hemodialysis vascular access flow. , 2008, Kidney international.

[29]  B. Manns,et al.  Economic implications of screening strategies in arteriovenous fistulae. , 2006, Kidney international.

[30]  D. Altman,et al.  Measuring inconsistency in meta-analyses , 2003, BMJ : British Medical Journal.

[31]  F. Loth,et al.  Frequency of critical stenosis in primary arteriovenous fistulae before hemodialysis access: should duplex ultrasound surveillance be the standard of care? , 2005, Journal of vascular surgery.

[32]  W. D. Paulson,et al.  Accuracy of Doppler ultrasound in diagnosing anatomic stenosis of hemodialysis arteriovenous access as compared with fistulography. , 1998, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[33]  F. Lopot,et al.  Comparison of Different Techniques of Hemodialysis Vascular Access Flow Evaluation , 2004, The International journal of artificial organs.

[34]  J. Bartoli,et al.  A new approach to evaluate vascular access in hemodialysis patients. , 1998, Artificial organs.

[35]  M. Moritz,et al.  Utility of intra-access pressure monitoring in detecting and correcting venous outlet stenoses prior to thrombosis. , 1995, Kidney international.

[36]  M. Allon,et al.  Vascular access stenosis: comparison of arteriovenous grafts and fistulas. , 2004, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[37]  T. Depner,et al.  Clinical measurement of blood flow in hemodialysis access fistulae and grafts by ultrasound dilution. , 1995, ASAIO journal.

[38]  R M Lindsay,et al.  A Comparison of Methods for the Measurement of Hemodialysis Access Recirculation and Access Blood Flow Rate , 1998, ASAIO journal.

[39]  R. Atkins,et al.  Native arteriovenous fistula blood flow and resistance during hemodialysis. , 2003, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[40]  R M Lindsay,et al.  Ultrafiltration method for measuring vascular access flow rates during hemodialysis. , 1999, Kidney international.

[41]  M. Dauzat,et al.  Fréquence des thromboses des fistules artério-veineuses pour hémodialyse: apport de deux méthodes de surveillance: le Doppler et la dilution des ultrasons , 2004 .

[42]  Sands Jj,et al.  Intervention based on monthly monitoring decreases hemodialysis access thrombosis. , 1999 .

[43]  R. Croxford,et al.  Reducing vascular access morbidity: a comparative trial of two vascular access monitoring strategies. , 2003, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[44]  H. Haruguchi,et al.  2005 Japanese Society for Dialysis Therapy Guidelines for Vascular Access Construction and Repair for Chronic Hemodialysis , 2006, Therapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy.

[45]  J. Portolés,et al.  [Prospective monitoring of vascular access in hemodialysis by means of a multidisciplinary team]. , 2006, Nefrologia : publicacion oficial de la Sociedad Espanola Nefrologia.

[46]  Marcello Tonelli,et al.  Hemodialysis clinical practice guidelines for the Canadian Society of Nephrology. , 2006, Journal of the American Society of Nephrology : JASN.

[47]  R. Roca-Tey,et al.  [Vascular access surveillance with blood flow monitoring: a prospective study with 65 patients]. , 2004, Nefrología.

[48]  M. Tonelli,et al.  Ultrasound monitoring to detect access stenosis in hemodialysis patients: a systematic review. , 2008, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[49]  S. Genovesi,et al.  Validation of QB stress test as a useful tool in the detection of native arteriovenous fistula stenosis: results after 22 months of follow-up. , 2010, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[50]  G. Lipari,et al.  A prospective controlled trial on effect of percutaneous transluminal angioplasty on functioning arteriovenous fistulae survival. , 2003, Journal of the American Society of Nephrology : JASN.

[51]  A. Lumsden,et al.  The Society for Vascular Surgery: clinical practice guidelines for the surgical placement and maintenance of arteriovenous hemodialysis access. , 2008, Journal of vascular surgery.

[52]  Antonio Lupo,et al.  Can blood flow surveillance and pre-emptive repair of subclinical stenosis prolong the useful life of arteriovenous fistulae? A randomized controlled study. , 2004, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[53]  N. Perico,et al.  Peripheral donor leukocytes prolong survival of rat renal allografts. , 1999, Kidney international.

[54]  A. Lupo,et al.  Bedside screening for fistula stenosis should be tailored to the site of the arteriovenous anastomosis. , 2011, Clinical journal of the American Society of Nephrology : CJASN.

[55]  B. Dixon,et al.  Monthly access flow monitoring with increased prophylactic angioplasty did not improve fistula patency. , 2005, Kidney international.

[56]  W. Daniel,et al.  Colour doppler ultrasound assessment of arteriovenous haemodialysis fistulas , 1992, The Lancet.

[57]  D. Hirsch,et al.  Screening for subclinical stenosis in native vessel arteriovenous fistulae. , 2001, Journal of the American Society of Nephrology : JASN.

[58]  V. Montori,et al.  Surveillance of arteriovenous hemodialysis access: a systematic review and meta-analysis. , 2008, Journal of vascular surgery.

[59]  A. Lupo,et al.  In search of an optimal bedside screening program for arteriovenous fistula stenosis. , 2011, Clinical journal of the American Society of Nephrology : CJASN.

[60]  Clark J Zeebregts,et al.  Within-session and between-session variability of haemodialysis shunt flow measurements. , 2005, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[61]  P. Blake,et al.  Hemodialysis access blood flow rates can be measured by a differential conductivity technique and are predictive of access clotting. , 1997, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[62]  P. Cluzel,et al.  Detection of Vascular Access Stenosis by Measurement of Access Blood Flow from Ionic Dialysance , 2002, Blood Purification.

[63]  R. Fluck,et al.  Renal Association Clinical Practice Guideline on Vascular Access for Haemodialysis , 2011, Nephron Clinical Practice.

[64]  M. Pestana,et al.  Physical examination of dysfunctional arteriovenous fistulae by non-interventionalists: a skill worth teaching. , 2012, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[65]  L. Salman,et al.  Accuracy of Ultrasound in the Detection of Inflow Stenosis of Arteriovenous Fistulae: Results of a Prospective Study , 2010, Seminars in dialysis.

[66]  Giovanni Morana,et al.  Diagnostic accuracy of ultrasound dilution access blood flow measurement in detecting stenosis and predicting thrombosis in native forearm arteriovenous fistulae for hemodialysis. , 2003, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[67]  M. Riella,et al.  Accuracy of Physical Examination and Intra‐Access Pressure in the Detection of Stenosis in Hemodialysis Arteriovenous Fistula , 2008, Seminars in dialysis.

[68]  L. Moist,et al.  Vascular Access Surveillance: Case Study of a False Paradigm , 2013, Seminars in dialysis.

[69]  N W Levin,et al.  Validation of haemodialysis recirculation and access blood flow measured by thermodilution. , 1999, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[70]  Antonio Lupo,et al.  Adding access blood flow surveillance to clinical monitoring reduces thrombosis rates and costs, and improves fistula patency in the short term: a controlled cohort study. , 2008, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[71]  M. Tonelli,et al.  Best threshold for diagnosis of stenosis or thrombosis within six months of access flow measurement in arteriovenous fistulae. , 2003, Journal of the American Society of Nephrology : JASN.

[72]  R. Roca-Tey,et al.  Five Years of Vascular Access Stenosis Surveillance by Blood Flow Rate Measurements during Hemodialysis Using the Delta-H Method , 2012, The journal of vascular access.

[73]  A. Asif,et al.  Physical Examination of Arteriovenous Fistulae by a Renal Fellow: Does It Compare Favorably to an Experienced Interventionalist? , 2008, Seminars in dialysis.