Tissue harmonic imaging improves organ visualization in trauma ultrasound when compared with standard ultrasound mode.

UNLABELLED The focused abdominal sonography for trauma (FAST) examination is complicated by brightly lit trauma bays, limited time, and body habitus. Recently, new ultrasound (US) technology has become available that improves organ visualization in abdominal scans. OBJECTIVE The hypothesis was that a new US mode, tissue harmonic (TH) imaging, improves visualization of critical organ relationships in the FAST examination by making use of previously unused frequencies. The authors performed a blind, prospective observational study to compare the images obtained in typical FAST views with those obtained in standard US and TH modes. METHODS Blunt trauma patients presenting to a level I trauma center between April and September 2000 were enrolled on a convenience basis. Typical FAST views were obtained in standard and TH modes. The emergency ultrasonographer (EU) switched between modes for each view, optimizing the gain each time. Multiple digital still images were made with all indications of the mode used disguised. For each view on a patient, the best image in each mode was selected in a blinded fashion. Three experienced EUs, blinded to the mode used, rated each image pair for resolution, detail, and total image quality as previously defined on a ten-point Likert scale, 10 being the best for each category. Wilcoxon signed-ranks test, 95% confidence intervals (95% CIs), and interobserver correlation were calculated. RESULTS A total of 76 image groups (39 of Morison's pouch, 20 splenorenal, and 17 bladder) from 52 patients were rated. Tissue harmonics produced improved resolution, detail, and quality when compared with the standard US mode, with median scores of 6.7 vs. 6.0, 6.7 vs. 6.0, and 6.3 vs. 6.0, respectively. The differences of 0.7 (95% CI = 0.4 to 0.93), 0.7 (95% CI = 0.4 to 0.93), and 0.33 (95% CI = 0.17 to 0.67) were statistically significant, with p = 0.0001, 0.0001, and 0.0003, respectively. There was good interobserver agreement (kappa = 0.74; 95% CI = 0.68 to 0.79). CONCLUSIONS Tissue harmonics produced FAST images higher in detail, resolution, and total image quality than standard-mode US images.

[1]  J. Mateer,et al.  Evaluation of hemoperitoneum using a single- vs multiple-view ultrasonographic examination. , 1995, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[2]  J F Greenleaf,et al.  Tissue harmonic imaging: experimental analysis of the mechanism of image improvement. , 2000, Japanese circulation journal.

[3]  G. Regel,et al.  Blunt abdominal trauma in cases of multiple trauma evaluated by ultrasonography: a prospective analysis of 291 patients. , 1992, The Journal of trauma.

[4]  H. Karamanoukian,et al.  Emergency department ultrasound in the evaluation of blunt abdominal trauma. , 1993, The American journal of emergency medicine.

[5]  R. Shapiro,et al.  Tissue harmonic imaging sonography: evaluation of image quality compared with conventional sonography. , 1998, AJR. American journal of roentgenology.

[6]  S. Stahmer,et al.  Targeted musculoarticular sonography in the detection of joint effusions. , 2001, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[7]  M. Blaivas,et al.  Incidence of pericardial effusion in patients presenting to the emergency department with unexplained dyspnea. , 2001, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[8]  H. Feußner,et al.  Moderne Diagnostik des stumpfen Bauchtraumas , 1999, Der Chirurg.

[9]  B. Boulanger,et al.  The indeterminate abdominal sonogram in multisystem blunt trauma. , 1998, The Journal of trauma.

[10]  M. Blaivas,et al.  Lower-extremity Doppler for deep venous thrombosis--can emergency physicians be accurate and fast? , 2000, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[11]  M. Dolich,et al.  2,576 ultrasounds for blunt abdominal trauma. , 2001, The Journal of trauma.

[12]  B. Boulanger,et al.  A prospective study of emergent abdominal sonography after blunt trauma. , 1994 .

[13]  M. Averkiou,et al.  Tissue harmonic imaging , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[14]  P. Knittel,et al.  The comparative accuracy of radiolucent foreign body detection using ultrasonography. , 1998, The American journal of emergency medicine.

[15]  F B Knotts,et al.  Emergency physician use of ultrasonography in blunt abdominal trauma. , 1996, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[16]  L Pourcelot,et al.  Clinical use of ultrasound tissue harmonic imaging. , 1999, Ultrasound in medicine & biology.

[17]  M. Blaivas,et al.  Emergency evaluation of patients presenting with acute scrotum using bedside ultrasonography. , 2001, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[18]  W H Dietz,et al.  The continuing epidemic of obesity in the United States. , 2000, JAMA.