Rapid and Selective Cyclic Voltammetric Measurements of Epinephrine and Norepinephrine as a Method To Measure Secretion from Single Bovine Adrenal Medullary Cells

Abstract : Background-subtracted cyclic voltammetry at a scan rate of 800 V/s with carbon fiber microelectrodes has been used to detect and differentiate between epinephrine and norepinephrine. At very positive potentials (>l V vs. SSCE) in pH 7.4 aqueous buffer, a second oxidation wave is observed for epinephrine, a secondary amine. In contrast, the second oxidation wave is not observed for norepinephrine, a primary amine. The amplitude of the second wave for epinephrine is enhanced when the waveform employed does not allow reduction of the electrogenerated o-quinone back to epinephrine. This indicates that the oxidation process at the second wave must be preceded by adsorption of the o- quinone at the electrode surface. The temporal response of the method was investigated by iontophoretic ejection of catecholamine onto an electrode. The response time was found to be limited by the repetition rate of the cyclic voltammograms (16.7 ms in this work). This electrochemical technique was used to resolve catecholamine release from individual vesicles of cultured bovine adrenal medullary cells. Most of the adrenal medullary cells released either epinephrine or norepinephrine but 17% of the cells released mixtures of these two compounds. In these cells, each secretory vesicle appeared to contain either epinephrine or norepinephrine.

[1]  R. Wightman,et al.  Principles of voltammetry and microelectrode surface states , 1993, Journal of Neuroscience Methods.

[2]  B. Perry,et al.  Histamine Evokes Greater Increases in Phosphatidylinositol Metabolism and Catecholamine Secretion in Epinephrine‐Containing than in Norepinephrine‐Containing Chromaffin Cells , 1993, Journal of neurochemistry.

[3]  J. A. Jankowski,et al.  Direct observation of epinephrine and norepinephrine cosecretion from individual adrenal medullary chromaffin cells , 1992 .

[4]  R. Engstrom,et al.  Measurements within the diffusion layer using a microelectrode probe , 1986 .

[5]  J. A. Jankowski,et al.  Analysis of diffusional broadening of vesicular packets of catecholamines released from biological cells during exocytosis. , 1992, Analytical chemistry.

[6]  R. Coupland Determining Sizes and Distribution of Sizes of Spherical Bodies such as Chromaffin Granules in Tissue Sections , 1968, Nature.

[7]  Robert H. Chow,et al.  Delay in vesicle fusion revealed by electrochemical monitoring of single secretory events in adrenal chromaffin cells , 1992, Nature.

[8]  E. Westhead,et al.  Th molecular organization of adrenal chromaffin granules , 1980, Neuroscience.

[9]  R. Engstrom Spatial resolution of electrode heterogeneity using iontophoresis , 1984 .

[10]  K. Burridge,et al.  Visualization of the exocytosis/endocytosis secretory cycle in cultured adrenal chromaffin cells , 1983, The Journal of cell biology.

[11]  M. Soriaga,et al.  Determination of the Orientation of Adsorbed Molecules at Solid-Liquid Interfaces by Thin-Layer Electrochemistry: Aromatic Compounds at Platinum Electrodes , 1982 .

[12]  J. A. Jankowski,et al.  Quantitative determination of catecholamines in individual bovine adrenomedullary cells by reversed-phase microcolumn liquid chromatography with electrochemical detection. , 1992, Analytical chemistry.

[13]  R. Wightman,et al.  Fast-scan voltammetry of biogenic amines. , 1988, Analytical chemistry.

[14]  M. A. Moro,et al.  Separation and culture of living adrenaline- and noradrenaline-containing cells from bovine adrenal medullae. , 1990, Analytical biochemistry.

[15]  Andrew G. Ewing,et al.  Characterization of submicron-sized carbon electrodes insulated with a phenol-allylphenol copolymer , 1992 .

[16]  Steven P. Wilson,et al.  Purification of adrenal chromaffin cells on renografin gradients , 1987, Journal of Neuroscience Methods.

[17]  J. A. Jankowski,et al.  Temporally resolved catecholamine spikes correspond to single vesicle release from individual chromaffin cells. , 1991, Proceedings of the National Academy of Sciences of the United States of America.

[18]  J. M. Fernández,et al.  Release of secretory products during transient vesicle fusion , 1993, Nature.

[19]  R. Wightman,et al.  Strategies for low detection limit measurements with cyclic voltammetry. , 1991, Analytical chemistry.

[20]  Jonathan A. Stamford,et al.  In vivo voltammetry: Some methodological considerations , 1986, Journal of Neuroscience Methods.

[21]  C. Nicholson,et al.  Measurement of nanomolar dopamine diffusion using low-noise perfluorinated ionomer coated carbon fiber microelectrodes and high-speed cyclic voltammetry. , 1989, Analytical chemistry.