Evaluation of the effect of shift cycle time on chest compression quality during cardiopulmonary resuscitation

Objective: Considering the potential role of shift cycle time on chest compression quality during cardiopulmonary resuscitation (CPR) and the available contradictory results in this regard, the present study aimed at evaluating the effect of 1-min versus 2-min shift cycle time on the quality of CPR. Materials and Methods: In this randomized crossover study, 80 rescuers performed CPR on a manikin in two scenarios with a rotation of 1 and 2-min cycles. The quality of CPR was evaluated and compared based on the information obtained regarding the chest compression depth, recoil, and rate of chest compression. In addition, rescuer fatigue was recorded in 1-min versus 2-min shift cycles. Results: In the 1-min group, the number of chest compressions per minute, complete recoil, and good rate with the mean of 114.89 ± 3.62, 54.34 ± 3.86, and 76.06 ± 8.00 were significantly higher than those of the 2-min group with the mean of 113.78 ± 4.94, 53.49 ± 5.27, and 73.98 ± 7.87 (P < 0.05), respectively. In addition, the quality of CPR provided by males was significantly higher than females in both groups. The score of rescuer fatigue was higher in the 2-min group as compared with the 1-min group (P < 0.001). Conclusion: According to the results of the present study, the difference in the quality of CPR in terms of the number of chest compressions, complete recoil, and good rate was higher in the 1-min group as compared with the 2-min group. In addition, the quality of CPR in terms of chest compression depth and number in both 1-and 2-min rotation cycles was higher for male rescuers than females. Furthermore, rescuer fatigue was higher in the 2-min group as compared with the 1-min group. The mentioned finding may be a factor in reducing, albeit slightly, the quality of CPR in the group with a longer time.

[1]  Chunshuang Wu,et al.  Effect of a feedback system on the quality of 2-minute chest compression-only cardiopulmonary resuscitation: a randomised crossover simulation study , 2019, The Journal of international medical research.

[2]  T. Gaszyński,et al.  Analysis of chest compression depth and rate during cardiopulmonary resuscitation with and without a feedback device , 2018 .

[3]  T. Kılıç,et al.  Resuscitation quality of rotating chest compression providers at one‐minute vs. two‐minute intervals: A mannequin study , 2017, The American journal of emergency medicine.

[4]  J. You,et al.  Influence of rescuer strength and shift cycle time on chest compression quality , 2017 .

[5]  B. Sánchez,et al.  Low compliance with the 2 minutes of uninterrupted chest compressions recommended in the 2010 International Resuscitation Guidelines. , 2015, Journal of critical care.

[6]  Dong Hoon Lee,et al.  Should we change chest compression providers every 2 min when performing one‐handed chest compressions? , 2015, Emergency medicine Australasia : EMA.

[7]  S. Timerman,et al.  Quality of continuous chest compressions performed for one or two minutes , 2015, Clinics.

[8]  A. Mehran,et al.  Results of CPR and Contributing Factor in Emergency Department of Sari Imam Khomeini Hospital, 2011-2013 , 2014 .

[9]  Gavin D Perkins,et al.  A randomised control trial of prompt and feedback devices and their impact on quality of chest compressions--a simulation study. , 2014, Resuscitation.

[10]  Y. Chan,et al.  Effect of Using an Audiovisual CPR Feedback Device on Chest Compression Rate and Depth. , 2014, Annals of the Academy of Medicine, Singapore.

[11]  Dong Hoon Lee,et al.  Comparison of chest compressions in the standing position beside a bed at knee level and the kneeling position: a non-randomised, single-blind, cross-over trial , 2013, Emergency Medicine Journal.

[12]  Thomas Seacrist,et al.  Chest Compression Quality Over Time in Pediatric Resuscitations , 2013, Pediatrics.

[13]  F. Kim,et al.  Nitrite therapy is neuroprotective and safe in cardiac arrest survivors. , 2012, Nitric oxide : biology and chemistry.

[14]  D. Hansen,et al.  Physical fitness affects the quality of single operator cardiocerebral resuscitation in healthcare professionals , 2012, European journal of emergency medicine : official journal of the European Society for Emergency Medicine.

[15]  S. Russo,et al.  Impact of physical fitness and biometric data on the quality of external chest compression: a randomised, crossover trial , 2011, BMC emergency medicine.

[16]  Young-Min Kim,et al.  Influence of physical fitness on the performance of 5-minute continuous chest compression , 2011, European journal of emergency medicine : official journal of the European Society for Emergency Medicine.

[17]  S. Manders,et al.  Alternating providers during continuous chest compressions for cardiac arrest: every minute or every two minutes? , 2009, Resuscitation.

[18]  B. Abella,et al.  Rescuer fatigue during actual in-hospital cardiopulmonary resuscitation with audiovisual feedback: a prospective multicenter study. , 2009, Resuscitation.

[19]  R. Berg,et al.  Rescuer fatigue: standard versus continuous chest-compression cardiopulmonary resuscitation. , 2006, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[20]  A. Jafarian EVALUATION OF SUCCESFUL CARDIOPULMONARY RESSUSCITATION (CPR) RATE IN HAFTOM TEER HOSPITAL , 2002 .

[21]  A. Keenan,et al.  Effect of rescuer fatigue on performance of continuous external chest compressions over 3 min. , 2002, Resuscitation.

[22]  S. Thomas,et al.  Decay in quality of closed-chest compressions over time. , 1995, Annals of emergency medicine.

[23]  Gavin D Perkins,et al.  CPREzy: an evaluation during simulated cardiac arrest on a hospital bed. , 2005, Resuscitation.