Directed graph mapping exceeds phase mapping in discriminating true and false rotors detected with a basket catheter in a complex in-silico excitation pattern

Atrial fibrillation (AF) is the most frequently encountered arrhythmia in clinical practise. One of the major problems in the management of AF is the difficulty in identifying the arrhythmia sources from clinical recordings. That difficulty occurs because it is currently impossible to verify algorithms which determine these sources in clinical data, as high resolution true excitation patterns cannot be recorded in patients. Therefore, alternative approaches, like computer modelling are of great interest. In a recent published study such an approach was applied for the verification of one of the most commonly used algorithms, phase mapping (PM). A meandering rotor was simulated in the right atrium and a basket catheter was placed at 3 different locations: at the Superior Vena Cava (SVC), the Crista Terminalis (CT) and at the Coronary Sinus (CS). It was shown that although PM can identify the true source, it also finds several false sources due to the far-field effects and interpolation errors in all three positions. In addition, the detection efficiency strongly depended on the basket location. Recently, a novel tool was developed to analyse any arrhythmia called Directed Graph Mapping (DGM). DGM is based on network theory and creates a directed graph of the excitation pattern, from which the location and the source of the arrhythmia can be detected. Therefore, the objective of the current study was to compare the efficiency of DGM with PM on the basket dataset of this meandering rotor. The DGM-tool was applied for a wide variety of conduction velocities (minimal and maximal), which are input parameters of DGM. Overall we found that DGM was able to distinguish between the true rotor and false rotors for both the SVC and CT basket positions. For example, for the SVC position with a CVmin=0.01cmms, DGM detected the true core with a prevalence of 82% versus 94% for PM. Three false rotors where detected for 39.16% (DGM) versus 100% (PM); 22.64% (DGM) versus 100% (PM); and 0% (DGM) versus 57% (PM). Increasing CVmin to 0.02cmms had a stronger effect on the false rotors than on the true rotor. This led to a detection rate of 56.6% for the true rotor, while all the other false rotors disappeared. A similar trend was observed for the CT position. For the CS position, DGM already had a low performance for the true rotor for CVmin=0.01cmms (14.7%). For CVmin=0.02cmms the false and the true rotors could therefore not be distinguished. We can conclude that DGM can overcome some of the limitations of PM by varying one of its input parameters (CVmin). The true rotor is less dependent on this parameter than the false rotors, which disappear at a CVmin=0.02cmms. In order to increase to detection rate of the true rotor, one can decrease CVmin and discard the new rotors which also appear at lower values of CVmin.

[1]  Jan Goedgebeur,et al.  Directed Networks as a Novel Way to Describe and Analyze Cardiac Excitation: Directed Graph Mapping , 2019, Front. Physiol..

[2]  Ulrich Schotten,et al.  Electropathological Substrate of Long-Standing Persistent Atrial Fibrillation in Patients With Structural Heart Disease: Longitudinal Dissociation , 2010, Circulation. Arrhythmia and electrophysiology.

[3]  G. Seemann,et al.  Slow Conduction in the Border Zones of Patchy Fibrosis Stabilizes the Drivers for Atrial Fibrillation: Insights from Multi-Scale Human Atrial Modeling , 2016, Front. Physiol..

[4]  Ashok J. Shah,et al.  Driver Domains in Persistent Atrial Fibrillation , 2014, Circulation.

[5]  N. Peters,et al.  Challenges Associated with Interpreting Mechanisms of AF , 2019, Arrhythmia & electrophysiology review.

[6]  J Clémenty,et al.  Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. , 1998, The New England journal of medicine.

[7]  Sanjiv M Narayan,et al.  Ablation of rotor and focal sources reduces late recurrence of atrial fibrillation compared with trigger ablation alone: extended follow-up of the CONFIRM trial (Conventional Ablation for Atrial Fibrillation With or Without Focal Impulse and Rotor Modulation). , 2014, Journal of the American College of Cardiology.

[8]  Bradley Porter,et al.  Unraveling the Underlying Arrhythmia Mechanism in Persistent Atrial Fibrillation: Results From the STARLIGHT Study , 2018, Circulation. Arrhythmia and electrophysiology.

[9]  A. Natale,et al.  Management of refractory atrial fibrillation post surgical ablation. , 2014, Annals of cardiothoracic surgery.

[10]  José Jalife,et al.  CrossTalk proposal: Rotors have been demonstrated to drive human atrial fibrillation , 2014, The Journal of physiology.

[11]  Wouter-Jan Rappel,et al.  Treatment of atrial fibrillation by the ablation of localized sources: CONFIRM (Conventional Ablation for Atrial Fibrillation With or Without Focal Impulse and Rotor Modulation) trial. , 2012, Journal of the American College of Cardiology.

[12]  Stephan Willems,et al.  Identification of Rotors during Human Atrial Fibrillation Using Contact Mapping and Phase Singularity Detection: Technical Considerations. , 2017, IEEE transactions on bio-medical engineering.

[13]  José Jalife,et al.  2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation , 2012, Heart rhythm.

[14]  Kalyanam Shivkumar,et al.  Long-term clinical outcomes of focal impulse and rotor modulation for treatment of atrial fibrillation: A multicenter experience. , 2016, Heart rhythm.

[15]  U. Schotten,et al.  Epicardial Fibrosis Explains Increased Endo–Epicardial Dissociation and Epicardial Breakthroughs in Human Atrial Fibrillation , 2020, Frontiers in Physiology.

[16]  Y. Rudy,et al.  Methodology Considerations in Phase Mapping of Human Cardiac Arrhythmias , 2016, Circulation. Arrhythmia and electrophysiology.

[17]  Jichao Zhao,et al.  Atrial fibrillation driven by micro-anatomic intramural re-entry revealed by simultaneous sub-epicardial and sub-endocardial optical mapping in explanted human hearts. , 2015, European heart journal.

[18]  Rafael Sebastián,et al.  Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study , 2018, PLoS Comput. Biol..

[19]  Seungyup Lee,et al.  Simultaneous Biatrial High-Density (510–512 Electrodes) Epicardial Mapping of Persistent and Long-Standing Persistent Atrial Fibrillation in Patients: New Insights Into the Mechanism of Its Maintenance , 2015, Circulation.

[20]  J Jalife,et al.  Mechanisms of atrial fibrillation: mother rotors or multiple daughter wavelets, or both? , 1998, Journal of cardiovascular electrophysiology.

[21]  M. Allessie,et al.  High-density mapping of electrically induced atrial fibrillation in humans. , 1994, Circulation.

[22]  Ashok J. Shah,et al.  Noninvasive mapping to guide atrial fibrillation ablation. , 2015, Cardiac electrophysiology clinics.

[23]  A. Verma,et al.  High-resolution noncontact charge-density mapping of endocardial activation. , 2019, JCI insight.

[24]  A. Waldo,et al.  Reconsidering the Multiple Wavelet Hypothesis of Atrial Fibrillation. , 2020, Heart rhythm.

[25]  Laura Martinez-Mateu,et al.  Far-field contributions in multi-electrodes atrial recordings blur distinction between anatomical and functional reentries and may cause imaginary phase singularities - A computational study , 2019, Comput. Biol. Medicine.

[26]  A. Verma,et al.  Focal source and trigger mapping in atrial fibrillation: Randomized controlled trial evaluating a novel adjunctive ablation strategy. , 2020, Heart rhythm.

[27]  José Jalife,et al.  Rebuttal from Sanjiv M. Narayan and José Jalife , 2014, The Journal of physiology.

[28]  Caroline H. Roney,et al.  Novel Radiofrequency Ablation Strategies for Terminating Atrial Fibrillation in the Left Atrium: A Simulation Study , 2016, Front. Physiol..

[29]  W. Rheinboldt,et al.  A COMPUTER MODEL OF ATRIAL FIBRILLATION. , 1964, American heart journal.

[30]  Zhilin Qu,et al.  Ablating atrial fibrillation: A translational science perspective for clinicians. , 2016, Heart rhythm.

[31]  M. Mansour,et al.  Mother rotors and fibrillatory conduction: a mechanism of atrial fibrillation. , 2002, Cardiovascular research.

[32]  M. Allessie,et al.  Direct Proof of Endo-Epicardial Asynchrony of the Atrial Wall During Atrial Fibrillation in Humans , 2016, Circulation. Arrhythmia and electrophysiology.

[33]  Paul J. Wang,et al.  Identification and Characterization of Sites Where Persistent Atrial Fibrillation Is Terminated by Localized Ablation , 2018, Circulation. Arrhythmia and electrophysiology.

[34]  P. Kirchhof,et al.  2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS. , 2016, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[35]  N. Trayanova,et al.  Patient-derived models link re-entrant driver localization in atrial fibrillation to fibrosis spatial pattern. , 2016, Cardiovascular research.

[36]  Jichao Zhao,et al.  Integration of High-Resolution Optical Mapping and 3-Dimensional Micro-Computed Tomographic Imaging to Resolve the Structural Basis of Atrial Conduction in the Human Heart. , 2015, Circulation. Arrhythmia and electrophysiology.

[37]  Maurits Allessie,et al.  Rebuttal from Maurits Allessie and Natasja de Groot , 2014, The Journal of physiology.

[38]  Hubert Cochet,et al.  Percolation as a mechanism to explain atrial fractionated electrograms and reentry in a fibrosis model based on imaging data. , 2016, Heart rhythm.

[39]  Sanghamitra Mohanty,et al.  Acute and early outcomes of focal impulse and rotor modulation (FIRM)-guided rotors-only ablation in patients with nonparoxysmal atrial fibrillation. , 2016, Heart rhythm.

[40]  Ulrich Schotten,et al.  Electropathological Substrate of Longstanding Persistent Atrial Fibrillation in Patients With Structural Heart Disease: Epicardial Breakthrough , 2010, Circulation.

[41]  Matthias Reumann,et al.  Multiple wavelets, rotors, and snakes in atrial fibrillation--a computer simulation study. , 2007, Journal of electrocardiology.

[42]  Sanghamitra Mohanty,et al.  Impact of Rotor Ablation in Nonparoxysmal Atrial Fibrillation Patients: Results From the Randomized OASIS Trial. , 2016, Journal of the American College of Cardiology.

[43]  Paul J. Wang,et al.  Two Independent Mapping Techniques Identify Rotational Activity Patterns at Sites of Local Termination During Persistent Atrial Fibrillation , 2017, Journal of cardiovascular electrophysiology.

[44]  B. Lindsay,et al.  Noninvasive Characterization of Epicardial Activation in Humans With Diverse Atrial Fibrillation Patterns , 2010, Circulation.

[45]  M. Ezekowitz,et al.  2014 AHA/ACC/HRS guideline for the management of patients with atrial fibrillation: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on practice guidelines and the Heart Rhythm Society. , 2014, Circulation.

[46]  M. Allessie,et al.  CrossTalk opposing view: Rotors have not been demonstrated to be the drivers of atrial fibrillation , 2014, The Journal of physiology.

[47]  Jichao Zhao,et al.  Three‐dimensional Integrated Functional, Structural, and Computational Mapping to Define the Structural “Fingerprints” of Heart‐Specific Atrial Fibrillation Drivers in Human Heart Ex Vivo , 2017, Journal of the American Heart Association.

[48]  Jens Eckstein,et al.  A computer model of endo-epicardial electrical dissociation and transmural conduction during atrial fibrillation. , 2012, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[49]  Alexander V Panfilov,et al.  Short-Lasting Episodes of Torsade de Pointes in the Chronic Atrioventricular Block Dog Model Have a Focal Mechanism, While Longer-Lasting Episodes Are Maintained by Re-Entry. , 2017, JACC. Clinical electrophysiology.

[50]  Prashanthan Sanders,et al.  Outcomes of long-standing persistent atrial fibrillation ablation: a systematic review. , 2010, Heart rhythm.